1 / 18

Hotel and Technology Drinking water and Legionella prophylaxis

Hotel and Technology Drinking water and Legionella prophylaxis. Source: www.tropenmedicus.de Berlin - Status: 05/2002 More than 80% of all diseases on travelling are traced back to contaminated drinking water. Which diseases are transmitted through water?

parry
Download Presentation

Hotel and Technology Drinking water and Legionella prophylaxis

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Hotel and Technology Drinking water and Legionella prophylaxis

  2. Source: www.tropenmedicus.de Berlin - Status: 05/2002 More than 80% of all diseases on travelling are traced back to contaminated drinking water. Which diseases are transmitted through water? Many diseases can be transmitted through dirty water. To this belong especially frequently bacterial diseases, e.g. with salmonellae, virus-diseases e.g. Hepatitis A and B, parasitic diseases e.g. with Toxoplasmas.

  3. Challenging electrical-, heating-, air-conditioning and sanitary technology Reliable service of these facilities Security standards are up-to-date Wellness technology with challenging background Hygiene at a high level Food processing fresh and hygienically faultless Water is a food! Hotel and Technology from the guest´s point of view

  4. Risks of this technology for the hotel image from the expert technician´s point of view

  5. Source: Deutsches Ärzteblatt Eckmanns, Tim; Lück, Christian; Rüden, Henning; Weist, Klaus Prevention nosocomial LegionellaDeutsches Ärzteblatt 103, Edition 19 vom 12.05.2006, Seite A-1294 / B-1099 / C-1059MEDIZIN SummaryLegionella are typical colonialists of drinking water supply systems which after the transmission to the human can initiate influenzavirus infections (Pontiac fever) as well as Pneumonia of different serverity codes. The number of legionnaires diseases is not sufficiently known and is estimated to 10,000 until 30,000. Thereof are appr. 20 % nosocomial legionnaires diseases.

  6. Thin water drops (Aerosols) are assimilated in the lung. Legionella (Sero groupe 0 and 1) proliferate frantically fast on the lung surface at blood heat and causes Pneunomia similar symptoms within a few days. Legionella are verifiable in every fresh water of the world. Stagnating water leads to the formation of biofilms. Biofilms protect millions of bacterias of all kinds. Legionella 1Risks at the sanitary facilities in respect of showers

  7. Increased water temperatures produce from bacteria food for other bacteria. Legionella in niches of pipeline connections and fittings are only thermally and chemically difficult reachable. Temperatures over 42 °C can cause scalds. High temperatures result in high energy costs. Thermal system disinfections are hardly feasible in practice. High temperatures damage pipeline systems and lead to limescales. Limescales cause service costs. Chemical permanently disinfections damage not only the human but also can destroy pipeline systems. Locations with the name „Bath“ must not disinfect the drinking water (chemical or UV-irradiation). Cold water can not be treated thermally. Legionella 2 Risks at the sanitary facilities in respect of showers

  8. Thin water drops (Aerosols) are assimilated in the lung. Legionella (Sero groupe 0 and 1) proliferate frantically fast on the lung surface at blood heat and causes Pneunomia similar symptoms within a few days. Legionella are verifiable in every fresh water of the world. Stagnating water leads to the formation of biofilms. Biofilms protect millions of bacterias of all kinds Chemical permanently disinfections damage not only the human but also can destroy pipeline systems. From shower entered Legionella don´t have often enough contact time with the disinfectant contained in the water, before these are routed via circulations to the water. LegionellaRisks in respect of Wellness and water attractions

  9. Hand shower with stagnation zone

  10. Thin water drops (Aerosols) are distributed (until appr. 200 m) in the surroundings of the cooling tower through natural air currents and can maybe assimilated in the lung by passersby and guests. Legionella (Sero groupe 0 and 1) proliferate frantically fast on the lung surface at blood heat and causes Pneunomia similar symptoms within a few days. Legionella are verifiable in every fresh water of the world. Stagnating water in the after feed pipeline to the cooling tower leads to the formation of biofilms and to strong Legionella population. In the circuit of cooling tower contained biocide can not deactivate the bacteria fast enough. Legionella reach the surroundinings of cooling tower. LegionellenRisks is respect of open cooling towers

  11. During the low season the public water supply has long stagnating times through low consumption in the water supply systems. The quality of the water supply differs very strongly. Hotel own Reservoirs and pipelines are not flowed through. The water stagnates and contaminates. This can be determined through a simple smell test at the Reservoir. The use of own sources of water is very complex with conventional technology. Bacteriological risks in the water supply

  12. Protection of single showers as 100% solution. Central protection with chemical support during the stagnating phases. Solution showers

  13. Protection of the whole hotel complex through Ultrafiltration. Solution water supply

  14. The Ultrafiltration membrane separates: Bacteria, parasites and virusus which are verifiable in spring- and groundwater Suspended matter, fine sand, mud and drops of opacity, (all of which are just a few microns in size and were caused by storms) from the through flowing water Ultrafiltration

  15. LEGIO.filter are used in drinking water supply systems in cooling towers in air washers in industrial and process engineering procedures Ultrafiltration

  16. Separation property Ultrafiltration

  17. Costs Legionella prophylaxis Single place unit protection LEGIO.panel from € 1.100,00 Current costs appr. € 30,00 per year Hotel with 50 beds LEGIO.filter Centre plant from € 8.000,00 Current costs appr. € 350,00 per year Hotel with 200 beds LEGIO.filter Centre plant from € 30.000,00 Current costs appr. € 950,00 per year Protection* of drinking water supply from unsafe public water supply systems Hotel with appr. 100 guests LEGIO.filter 1,4 m3/h from € 13.000,00 Hotel with appr. 400 guests LEGIO.filter 3,5 m3/h from € 29.000,00 Hotel with appr. 1000 guests LEGIO.filter 7,0 m3/h from € 55.000,00 Hotel with appr. 2000 guests LEGIO.filter 20,0 m3/h from € 98.000,00 Protection from contaiminated city water before the Reservoir. Basic cleaning of the following Reservoir and protection of re-contaimination in the Reservoir, according to constructional expenses € 400,00 to € 10.000,00. Prices without automatical disinfection and without telemonitoring. Surplus price appr. € 10.000,00. All prices are ex works plus arising taxes in additional.

  18. More than 80% of all diseases on travelling are traced back to contaminated drinking water.