1 / 7

Air-cooled small chillers

Air-cooled small chillers. 33kW (9,4TR), 80kW (22,7TR), 110kW (31,3TR). Page 1. Aquaflair Applications. Critical Environments Data Centers Computer Centers LAN Rooms Laboratories Industrial processes Process Cooling / industrial Transportation Food and Beverage Healthcare

noelle
Download Presentation

Air-cooled small chillers

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Air-cooled small chillers 33kW (9,4TR), 80kW (22,7TR), 110kW (31,3TR) Confidential Property of Schneider Electric | Page 1

  2. Aquaflair Applications Critical Environments • Data Centers • Computer Centers • LAN Rooms • Laboratories Industrial processes • Process Cooling / industrial • Transportation • Food and Beverage • Healthcare • Energy Confidential Property of Schneider Electric |

  3. Technical Vs Comfort chillers AvailableModifications are necessaryComplete design isnecessary Confidential Property of Schneider Electric |

  4. Small and mid chillers 33kW (9,4 TR) 80kW (22,7 TR) 110kW (31,3 TR) Air-cooled small and mid chillers kW LRAC180A ERAC0921A ISAC1221A Air-cooled chillers Performance data refer to nominalconditions: water inlet/outlet temperature 12/7°C; outdoor ambient temperature 35°C; 0% glycol

  5. ISAC1221A VSD compressors Scroll compressors • One inverter driven scroll compressor + one fixed speed scroll compressor • Environmentally friendly R410A • Single passage plate heat exchanger • Finned tube condensing coils • Quiet noise version • Electronic Expansion Valve • AC/EC fans • Integrated soft start & PFCs • High / Low ambient temperature operation (+ 50 down to -20°C) Main features Confidential Property of Schneider Electric |

  6. High water temperatures LRAC / ERAC / ISAC Operationat high water temperature and wide delta T LRAC/ERAC/ISAC units can efficiently operate at high water temperatures and wide delta T High water temperatures & wide deltaT are mandatory to comply with ASHRAE standards improve OPEX: • Pump power saving • Less power consumption on fan side allow CAPEX reduction • Saving on hydraulic infrastructure • Reduced pressure drops ISAC1221A – Mumbai 100kW, delta T = 5°C Annualenergyconsumption @ 7/12°C is 216000 kWh Confidential Property of Schneider Electric |

More Related