Modular Capacity - Test - System CS - 3001

Modular Capacity - Test - System CS - 3001. Modular test system Easy to operate Expandable up to 4 strings with 192 voltage inputs Block voltage : ± 16,6 VDC , (detection of voltage reversals) 600VDC CAT III (5000VAC test voltage) Parallel test of up to 4 batteries. Connection area.

neo
Download Presentation

Modular Capacity - Test - System CS - 3001

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ModularCapacity - Test - SystemCS - 3001

  2. Modular test system • Easy to operate • Expandable up to 4 strings with 192 voltage inputs • Block voltage : ± 16,6 VDC, (detection of voltage reversals) • 600VDC CAT III (5000VAC test voltage) • Parallel test of up to 4 batteries

  3. Connection area

  4. Connection example Standard 4mm safety connection

  5. Bus area

  6. Bus connection • Daisy chain connection • Power supply and communication in a single cable • Standard RJ45 cable Each string of modules can have a total connection length of > 100m

  7. Connection example of a 24VDC battery Bluetooth communication

  8. Testing of an UPS ( 2 racks with 5 x 4 x 12V-Block) For ease of contact, not all input channels of a module must be used. Only the blocks on one level of a cabinet need to be connected

  9. Maximum installation 1 2 31 32 RJ 45 CS-3001 Module CS-3001 Module CS-3001 Module CS-3001 Module String 1 DC IN RJ 45 CS-3001 Module CS-3001 Module CS-3001 Module CS-3001 Module String 2 RJ 45 CS-3001 Module CS-3001 Module CS-3001 Module CS-3001 Module String 3 DC IN RJ 45 CS-3001 Module CS-3001 Module CS-3001 Module CS-3001 Module String 4 CS-3001/PU 4 x 192 x 2V-Block

  10. Safety aspects Resistance between any input > 2 MΩ (leakage < 0,3 mA) • The system uses no fragile mechanical relays for scanning the block voltages. • Semiconductor switches for voltage selection has been eliminated. • Defect switches can cause an electric shock, if no protection gloves are used. 5000 VAC Isolation