1 / 6

DAQ Layout

DAQ Layout. MiniCrate. TrgBrd. TrgBrd. TrgBrd. SrvBrd. CCB. ROB. ROB. ROB. ROB. ROB. Front-End. DT Chamber 2. Front-End. DT Chamber 1. Alimentatore LV. ROB. ROB. ROB. ROB. ROB. TrgBrd. TrgBrd. CCB. TrgBrd. SrvBrd. HV-Controller. Control/Monitor MiniCrate. MiniCrate.

najila
Download Presentation

DAQ Layout

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DAQ Layout MiniCrate TrgBrd TrgBrd TrgBrd SrvBrd CCB ROB ROB ROB ROB ROB Front-End DT Chamber 2 Front-End DT Chamber 1 Alimentatore LV ROB ROB ROB ROB ROB TrgBrd TrgBrd CCB TrgBrd SrvBrd HV-Controller Control/Monitor MiniCrate MiniCrate Trigger Data TDC data TRG BSY Max 15 m Fibra TTCvi TTCex VME ROS ROS PU PU Readout Unit (XDAQ) TRG Builder Unit (XDAQ) BSY Data Storage Internet HV Server Monitor (ORCA) Spy events RCS Server MiniCrate Server (XDAQ) UI HV UI MiniCrt UI Monitor UI RCS

  2. Trigger Synch (da discutere) PRELIMINARY L1A trigger scintillatori clk40MHZ clock bx start/stop PU X 2 orbit busy

  3. Da discutere • Data Storage • Evitare se possibile il central data recording del cern (va su Castor). Si puo fare in con ftp in batch • Mettere un pool di dischi (> 500 Gbyte) in Raid5 on-line con la BU (o come disk server locale alla rete del DAQ) • Backup ? • Su cassette? LTO ? NO • Backup a LNL sui dischi della farm CMS o di LNL? Troviamo facilmente 1-2 TeraByte libero per maggio. OK, ma non in alternativa al CDR • Eventuale analisi dati durante il test beam sulle macchine cmsfarm010 e cmsfarm011 • Monitor di fisica (ORCA) • Aggiornato all’ultima versione di ORCA • Legge i dati dal file che si sta scrivendo on-line (o da quelli precedentemente scritti) • Altre possibilita’?: • XDAQ event filter framework ? Vedi lavoro di Emilio NO • Run Control • Console di comando in Java • Procedure di scripting in TCL (forse disponibile anche Java interpretato) • Error logger Builder Unit (XDAQ) Protocollo Definito (TDR) EF - Monitor (XDAQ) Logger Status Display RU RCS BU UI MC Server HV Server

  4. HV e MiniCrate Server HV Server • HV Server • Lavora in standalone per settare le HV • Ci sono interazioni con il RCS? Si • Allarmi asincroni da gestire? Non chiaro • Le HV vanno scritte da qualche parte? • Quando? (start del run?) SI • Dove? (flusso dati?) Si • MiniCrate Server • Lavora in standalone per settare il miniCrate (riempie il DB di configurazione, carica il MC) • Ha un DB di configurazione (che puo’ essere anche una semplice directory) • Puo’ lavorare comandato dal RCS • Parametri da memorizzare nel data flow principale allo start del run? • Soglie FE? • Temperature FE ? • Temperature MC • Allarmi asincroni da gestire? • Si va in polling sulla CCB (per esempio durante lo spill off) con comando specializzato per prelevare le informazioni di stato. Queste possono venire salvate per esempio nel logger del RCS o dove si vuole http server RCS Server

  5. MiniCrate Server (II) • Il setup del MC viene fatto in standalone • da un programma apposito. Il setup viene scritto in un DB. • Il setup riguarda i seguenti componenti del MC • parametri ROB • parametri TrgBrd • parametri FE • ecc RCS MC Server Soap MC Cnfg DB LV UI • In Run-Mode (durante l’acquisizione dati) RCS comanda MC server per: • scegliere e caricare dal DB le configurazioni del MC • start/stop ROB e TrgBrd (?) • Monitor parametri FE? • Monitor TrgBrd? Una UI scritta in LV interagisce direttamente Con il MC server ed il suo DB per il setup dei Parametri. E’ possibile fare anche il caricamento del MC.

  6. Monitor check hardware(indipendente dal monitor di fisica) 1 Builder Unit (XDAQ) Data Storage Monitor (ORCA) • time box • celle%time • ecc. Root Monitor Spy events DA VALUTARE SE NE VALE LA PENA 2 BU PC BU Histo Prod Histo DB (on mem) Esportabile da XDAQ LV Histo Viewer