[10001] Time-delay Information Blockette (18 bytes). Name: Blockette Type:. Time-delay Information Blockette 10001. Note. Field name. Type. Length. Mask or Flags. 1 2 3 4 5 6 7 8 9 10. Blockette type - 10001 Length of blockette type Data transferred path

mlucinda
Download Presentation

[10001] Time-delay Information Blockette (18 bytes)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. [10001] Time-delay Information Blockette (18 bytes) Name: Blockette Type: Time-delay Information Blockette 10001 Note Field name Type Length Mask or Flags 1 2 3 4 5 6 7 8 9 10 Blockette type - 10001 Length of blockette type Data transferred path Time delay to instrument Time delay to node Time difference with GPS Unit of the item 4 Unit of the item 5 Unit of the item 6 Other Information B B B B B B B B B B 2 2 1 4 4 4 4 4 4 1 Notes for fields: 1 UWORD: Blockette type [10001]: Time-delay information blockette. 2 UWORD: Byte number of next blockette. 3 UBYTE: Data transferred path along the cable. Clockwise (0) and counterclockwise (1). 4 LONG: Transfer time delay to instrument. Unit is micro second. 5 LONG: Transfer time delay to node. Unit is micro second. 6 LONG: Time difference between GPS and record. Unit is micro second. 7 FLOAT: Sampling frequency (Hz) for the unit of the item 4. 8 FLOAT: Sampling frequency (Hz) for the unit of the item 5. 9 FLOAT: Sampling frequency (Hz) for the unit of the item 6. 10 UBYTE: Other information except the above 1-6 items.

  2. [10002] Instrument Control Blockette (15 bytes) Name: Blockette Type: Instrument Control Blockette 10002 Note Field name Type Length Mask or Flags 1 2 3 4 5 6 7 Blockette type - 10002 Length of blockette type Status of gimbal motor Power voltage Power current Control signal for sensor Other information B B B B B B B 2 2 1 4 4 1 1 Notes for fields: 1 UWORD: Blockette type [10002]: Instrument control blockette. 2 UWORD: Byte number of next blockette. 3 UBYTE: Status of gimbal motor. On (1), off(0), no response (9), or other troubles (999). 4 FLOAT: Measurement results of power voltage at instrument. Unit is V. 5 FLOAT: Measurement results of power current at instrument. Unit is A. 6 UBYTE: Control signal for sensor. Running (1), power off (0), no response (9), or other troubles (999). 7 UBYTE: Other information except the above 1-7 items.

  3. [10003] Power Supply Information Blockette (6 bytes) Name: Blockette Type: Power Supply Information Blockette 10003 Note Field name Type Length Mask or Flags 1 2 3 4 5 Blockette type - 10003 Length of blockette type Status of power supply Status of data Other information B B B B B 2 2 1 1 1 Notes for fields: 1 UWORD: Blockette type [10003]: Instrument control blockette. 2 UWORD: Byte number of next blockette. 3 UBYTE: Status of power supply. Normal (1), stopped(0), no response (9), or other troubles (999). 4 UBYTE: Status of data record. Normal data (1), back up data on site (0), or other troubles (999). 5 UBYTE: Other information except the above 1-4 items.

  4. [10004] Node Condition Blockette (18 bytes) Name: Blockette Type: Node Status Blockette 10004 Note Field name Type Length Mask or Flags 1 2 3 4 5 6 Blockette type - 10004 Length of blockette type Connected node Power voltage at the node Power current at the node Other information B B B B B B 2 2 1 4 4 1 Notes for fields: 1 UWORD: Blockette type [10004]: Instrument control blockette. 2 UWORD: Byte number of next blockette. 3 UBYTE: Idenfication number of connected node (A-E → 1-5), non-connected (0), or non-identified (999). 4 FLOAT: Measurement results of power voltage at node. Unit is V. 5 FLOAT: Measurement results of power current at node. Unit is A. 6 UBYTE: Other information except the above 1-5 items.

  5. [10005] Land Station Information Blockette (23 bytes) Name: Blockette Type: Land Station Information Blockette 10005 Note Field name Type Length Mask or Flags 1 2 3 4 5 6 7 Blockette type - 10005 Length of blockette type Status of land station Power voltage at land station Power current at land station Number of detected GPS Other information B B B B B B B 2 2 1 4 4 1 1 Notes for fields: 1 UWORD: Blockette type [10005]: Instrument control blockette. 2 UWORD: Byte number of next blockette. 3 UBYTE: Status of exchanged land station. On (1), off(0), no response (9), or other troubles (999). 4 FLOAT: Measurement results of power voltage at land station. Unit is V. 5 FLOAT: Measurement results of power current at land station. Unit is A. 6 UBYTE: Number of detected GPS. 7 UBYTE: Other information except the above 1-6 items.

  6. [10050] Quartz Pressure Blockette (61 bytes) Name: Blockette Type: Quartz Pressure Blockette 10050 Note Field name Type Length Mask or Flags 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Blockette type - 10050 Length of blockette type Temperature coefficient U0 Temperature coefficient Y1 Temperature coefficient Y2 Temperature coefficient Y3 Pressure coefficient C1 Pressure coefficient C2 Pressure coefficient C3 Pressure coefficient D1 Pressure coefficient D2 Pressure coefficient T1 Pressure coefficient T2 Pressure coefficient T3 Pressure coefficient T4 Pressure coefficient T5 Other information B B B B B B B B B B B B B B B B B 2 2 4 4 4 4 4 4 4 4 4 4 4 4 4 4 1

  7. Notes for fields: 1 UWORD: Blockette type [10050]: Quratz pressure blockette. 2 UWORD: Byte number of next blockette. 3 FLOAT: Coffecient of temperature: U0 4 FLOAT: Coffecient of temperature: Y1 5 FLOAT: Coffecient of temperature: Y2 6 FLOAT: Coffecient of temperature: Y3 7 FLOAT: Coffecient of pressure: C1 8 FLOAT: Coffecient of pressure: C2 9 FLOAT: Coffecient of pressure: C3 10 FLOAT: Coffecient of pressure: D1 10 FLOAT: Coffecient of pressure: D1 11 FLOAT: Coffecient of pressure: D2 12 FLOAT: Coffecient of pressure: T1 13 FLOAT: Coffecient of pressure: T2 14 FLOAT: Coffecient of pressure: T3 15 FLOAT: Coffecient of pressure: T4 16 FLOAT: Coffecient of pressure: T5 17 UBYTE: Other information except the above 1-16 items.

  8. [10060] Temperature Calibration Blockette (13 bytes) Name: Blockette Type: Temperature Calibration Blockette 10060 Note Field name Type Length Mask or Flags 1 2 3 4 5 Blockette type - 10060 Length of blockette type Zero Span Other information B B B B B 2 2 4 4 1 Notes for fields: 1 UWORD: Blockette type [10060]: Temperature blockette. 2 UWORD: Byte number of next blockette. 3 FLOAT: Zero value. 4 FLOAT: Span value. 5 UBYTE: Other information except the above 1-4 items.