An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MICROSCOPIA ELECTRÒNICA Melo E, Sastre S, Sebastia I, Soler R, Tubert L et al.

  2. QUÈ ÉS LA ME? Tècnica que permet visualitzar estructures indetectables per l’ull humà. Límit teòric de resolució  0,002nm. Problemes causats per: -disseny lents electromagnètiques -problemes preparació mostres biològiques i contrast Límit pràctic de resolució  2nm.

  3. RMN • Petites molècules • Dominis proteïnes • Detalls de dinàmica molecular • Estudi macromolècules en solució aquosa • No cristal·lització • Mg de proteïna • Alta solubilitat en aigua • > 30 kD

  4. Cristalografia rajos X • Determinació estructura ràpida • No en solució • Cristalls difractants • Proteïnes poden formar agregats • Solubilització poc exigent • Sense mida límit (només cal cristal·litzar)

  5. EM • Estudi al buit • Evitar la deshidratació mostra • Dany per radiació • Baixes dosis electrons • Micrografies 2D3D • Menor resolució

  6. SEM TEM • Obtenim la imatge a partir dels e- que són reflexats i • dispersats de la mostra - Es basa en el pas dels e- a través de la mostra - Aporta informació 2D i 3D

  7. TRANSMISSION EM Filament tungstè font e- Ànode Lents condensadores Mostra Lents de l’objectiu Lents de projecció Sistema detecció

  8. SEM TEM 1/gruix INTERACCIÓ FEIX ELECTRONS I MOSTRA

  9. PRINCIPIS DE FORMACIÓ DE LA IMATGE • Quan un e- arriba a la mostra, poden passar dos fenòmens: • si l’e- no xoca  trajectòria recta • si l’e- xoca  xocs inelàstics : sense pèrdua d’Energia • xocs elàstics :transfereix part de l’Ec a la mostra • Dany per radiació

  10. - Els e- que travessen la mostra impacten sobre el detector produint una imatge en 2D (projecció) - Posteriorment s’escaneja la micrografia (digitalització)

  11. PODER DE RESOLUCIÓ

  12. RESOLUCIÓ • Resolució de 20-30 Å  proteïnes individuals • Resolució 8-9Å  hèlix alfa • Resolució 5 Å  fulles beta • Resolució 3-4 Å cadenes aminoàcids

  13. Nº partícules Resolució t (anys) Evolució de la resolució de l’estructura del ribosoma entre 1990 i 2000

  14. Structure of the human transferrin receptor-transferrin complex.Cheng Y, Zak O, Aisen P, Harrison SC, Walz T. • Cell. 2004 Feb 20;116(4):565-76. Resolució 7.5 Å

  15. PREPARACIÓ DE LA MOSTRA EN ME • Fixació (aldehids) • Staining (substàncies electrodenses) • Deshidratació (alcohols) • Immersió en resina • Seccions ultrafines amb ultramicròtom (50-100 nm de gruix) 1a) Negative staining (OsO4) 1b) Shadowing (metalls pesats) 1c) Crio-Microscopia

  16. 1c. CRIO-MICROSCOPIA • Mol·lècules grans (>500 KDa), no cristal·litzables • La mostra es vitrifica i no se n’obtenen seccions • TEM • Millor resolució • Reconstruccions 3D de virus, proteïnes i complexes proteics...

  17. CRIO-ME i RECONSTRUCCIÓ 3D • Preparació de la mostra • Obtenció de la micrografia • Selecció de les partícules • Centrat i Alineament de les partícules • Classificació de les partícules • Orientació • Reconstrucció 3D

  18. 1) PREPARACIÓ de la MOSTRA en CRIO-ME • La mostra es diposita sobre una reixa que conté una làmina de carbó • Les mostres han de congelar-se a –150 ºC amb età formant una làmina de gel vitrificat (evita la formació de bombolles) • Evitar descongelació i deshidratació  manteniment en N líquid • Cal evitar la formació de cristalls d’aigua  vitrificació mostra età N líquid

  19. CRIO-ME • En no deshidratar la mostra proteïna manté la mateixa conformació que en solució + llibertat  + orientacions • No utilitzem tinció  no distorsió mostra • La baixa Tº disminueix el dany produït pels electrons • No utilitzem metalls pesats • menys contrast amb el fons • caldrà desenfocar • pèrdua de resolució • Treballa a baixa dosi d’e-

  20. 2) OBTENCIÓ DE MICROGRAFIES • Preparació de moltes mostres • De cada mostra només obtenim una o dues micrografies

  21. COM OBTENIM LA IMATGE 3D A PARTIR DE LES PROJECCIONS 2D ? “Las apariencias engañan”

  22. La MICROGRAFIA ELECTRÒNICA és una representació 2D d’un objecte 3D Per la reconstrucció 3D calen múltiples micrografies obtingudes en diferents angles (projeccions)  inclinació de la mostra

  23. Cal assignar els angles d’Euler a cada projecció. Els angles d’Euler s’usen per descriure qualsevol punt a la superficie de l’esfera  indiquen la posició i la orientació entorn al centre Theta : altura per sobre o per sota l’equador. Phi : rotació al llarg de l’equador. Psi : rotació entorn el centre de la posició definida per theta i phi

  24. 3) SELECCIÓ DE PARTÍCULES 4) CENTRAT I ALINIAMENT 5) CLASSIFICACIÓ 6) ORIENTACIÓ IMATGE 3D MÈTODE DE RECONSTRUCCIÓ 3D · CONICAL TILT · COMMON LINES

  25. RECONSTRUCCIÓ 2D 3D • 1)Random Conical Tilt o single axis tilt • Parells de micrografies de la mostra: (0º i 50 º). • Pèrdua d’informació  Missing cone

  26. 2) Common Lines o angular reconstitution Donat un objecte 3D, i moltes projeccions 2D, només hi ha una sola combinació de les projeccions 2D que doni lloc a l’objecte. Intersecció entre 2 projeccions en l’espai de Fourier

  27. FFT IFT Les densitats són representades per pixels en les imatges digitalitzades (espai real). L’espai Fourier és una representació matemàtica alternativa d’una imatge que descriu la imatge utilitzant fases i amplituds enlloc de densitats (associades amb els píxels de l’espai real)

  28. Sz Sy Sy Sz Sx Sx Sy Sy Sx Sx

  29. ESPAI FOURIER Múltiples projeccions IFT MODEL REFINAT MODEL PRELIMINAR

  30. VEIEM UN EXEMPLE DE RECONSTRUCCIÓ 3D AMB CRIO-MICROSCOPIA ELECTRÒNICA

  31. Micrografia digital crio-EM Ad2 (150 Mda) Micrografia digital crio-EM DNA-PKcs(470 kDa)

  32. Ad2 DNA-PKcs

  33. COMBINACIÓ CRIO-EM I RAJOS X 7.6 Å Virus sencer a 20 Å 10 Å

  34. BIBLIOGRAFIA • Adding the third dimension to virus life cycles: three-dimensional reconstruction of icosahedral viruses from cryo-electron micrographs. Baker TS, Olson NH, Fuller SD. Microbiol Mol Biol Rev. 1999 Dec;63(4):862-922 • Three-dimensional electron cryo-microscopy as a powerful structural tool in molecular medicine. Auer M. J Mol Med. 2000;78(4):191-202. • Digitally collected cryo-electron micrographs for single particle reconstruction.Stewart PL, Cary RB, Peterson SR, Chiu CY. Microsc Res Tech. 2000 May 1;49(3):224-32. • Single particle macromolecular structure determination via electron microscopy.Thuman-Commike PA. FEBS Lett. 2001 Sep 14;505(2):199-205. • Three-dimensional reconstruction of single particle electron microscopy: the voltage sensitive sodium channel structure. Yutaka Ueno, Chikara Sato. Science Progress (2001), 84 (4), 291–309. • Cryo-electron microscopy as an investigative tool: the ribosome as an example.Frank J. Bioessays. 2001 Aug;23(8):725-32. • Light and electron microscopy. Elizabeth M. Slayter, Henry S. Slayter. Cambridge Cambridge University Press 1992 • Guide to microscopy. Wayne M. Becker, Lewis J. Kleinsmith, Jeff Hardin.San Francisco [etc.] Benjamin/Cummings cop. 2003 • http://cryoem.berkeley.edu/~nieder/em_for_dummies/

  35. 1. En crio-microscopia electrònica, assenyala la resposta correcta:a)     Els passos a seguir des de l’obtenció de la micrografia i fins a l’obtenció del model 3D són: selecció, alineament, centrat, classificació i orientació de les partícules. b)     Els angles d’Euler d’un icosàedre són dosc)     les dues anteriors són certesd)     el random conical tilt treballa amb aproximadament 10 projeccions de cada mostrae)     Totes les anteriors són falses.2. Asenyala les opcions correctes sobre crio-ME:Es pot definir una micrografia com la representació en 2D d’un objecte de 3D.En el mètode de common lines es pren una imatge a 0º i l’altra a 90º, perquè aquestes permetran millorar la informació que s’obté de la mostraDos mètodes principals en la reconstrucció de les imatges 3D : random conical tilt i common linesEn la classificació de les partícules, es realitzarà la rotació i translació d’aquestes, per tenir-les en la mateixa orientacióa)      1,2 i 3b)     1,3c)      2 i 4d)      4e)      1,2,3 i 4 PEM

  36. 3. Indica les afirmacions correctes sobre crio-ME: a)les mostres han de ser vitrificades b)per preparar les mostres, s’usa una reixa sobre la qual hi ha una làmina fina de PEG c)les dues anteriors són certes d)la mostra es tenyeix amb metalls pesants e)totes les anteriors són certes 4. Sobre la crio-ME: a)es treballa sempre amb la mostra a baixa temperatura b)és necessari un flux d’electrons molt gran per prendre les imatges c)una avantatge de la crio es que en no treballar amb metalls pesats no es distorsiona la mostra d)la mostra es deshidrata e)la a i la c són correctes 5. En referència a la microscopia electrònica, la màxima resolució a la qual podem arribar és: a)2 nm b)la que permet visualitzar fulles betes c)les dues anteriors són certes. d)2*10-12 mm e)cap de les anteriors

  37. 6. Respecte els mètodes de reconstrucció 3D en crio-microscopia electrònica, assenyala la falsa a) Un dels mètodes utilitzats per fer la reconstrucció 3D es diu Common lines o angular reconstruction. b) És possible construir un model 3D a partir d’una projecció 2D. c) Un cop obtingut el model 3D preliminar, aquest es refina amb cicles iteratius de re-alineament i re-orientació de les partícules. d) La informació obtinguda per crio-microscopia electrònica es pot complementar amb la informació de cristal·lografia de raigsX, i viceversa. e) Totes les anteriors són falses 7. Respecte el mètode de reconstrucció 3D de Common lines o angular reconstruction, assenyala la falsa a) Les projeccions 2D són plans en l’espai Fourier. b) Existeixen múltiples combinacions en la orientació de les projeccions 2D que donen lloc al mateix objecte 3D. c) La transformada de Fourier de les imatges 2D es projecta sobre l’espai Fourier 3D. d) Per obtenir el model 3D preliminar cal tornar a l’espai real aplicant la inversa de la Transformada de Fourier. e) Generalment, per la reconstrucció d’un virus icosaèdric es requereixen menys projeccions que per la reconstrucció d’una proteïna assimètrica.

  38. 8. Amb un microscopi electrònic podem arribar a veure: a) proteïnes b) hèlix alfa c) les dues anteriors d) làmines beta e) totes les anteriors 9. Assenyala la resposta correcta: a) L'alta resolució de la microscopia electrònica s'explica per la llarga longitud d’ona dels electrons, que fa que aquests puguin travessar millor els teixits b) A la tinció negativa s'utilitzen metalls pesats que permeten una millor resolució c) Aquells electrons que xoquen amb la mostra de forma elàstica transferiran totalment la seva energia a la mostra d) Només seran informatius a l’hora de formar la imatge, aquells electrons que travessin perpendicularment la mostra i aquells que xoquin de forma inelàstica. e) Totes les anteriors són falses

  39. 10. Respecte la ME, assenyala les respostes correctes: 1.Degut al mètode de preparació de la mostra, en la microscopia electrònica convencional les proteïnes conserven la seva estructura nativa. 2.En la crio-microscopia electrònica les mostres es congelen per submersió en nitrogen líquid. 3.Per obtenir una bona resolució en crio-ME cal fer seccions ultrafines de les mostres (50-100 nm de gruix) amb un ultramicròtom. 4.El ME de transmissió utilitza lents electromagnètiques enlloc de lents de vidre, per tal d’orientar el feix d’electrons cap a la mostra. a)1,2 i 3 b)1,3 c)2 i 4 d)4 e)1,2,3 i 4