ABSORB: 6-Month and 2-Year Results

ABSORB: 6-Month and 2-Year Results. Minimum lumen diameter (MLD): 2.3 mm after procedure and 1.9 mm at 6 months Percent stenosis: 16% post-procedure, 27% at 6 months, and 27% at 2 years Late-loss: 0.43 mm at 6 months and 0.48 mm at 2 years One non-Q-wave MI occurred within 2 years.

lis
Download Presentation

ABSORB: 6-Month and 2-Year Results

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ABSORB: 6-Month and 2-Year Results Minimum lumen diameter (MLD): 2.3 mm after procedure and 1.9 mm at 6 months Percent stenosis: 16% post-procedure, 27% at 6 months, and 27% at 2 years Late-loss: 0.43 mm at 6 months and 0.48 mm at 2 years One non-Q-wave MI occurred within 2 years Trial design: Patients with a focal native coronary artery stenosis were treated with a bioabsorbable everolimus-eluting stent to determine safety and efficacy (n = 30). Results (p < 0.001) (p < 0.001) 27 2.3 1.9 16 mm Conclusions • PCI of simple coronary stenoses—feasible with bioabsorbable everolimus-eluting stent • One non-Q-wave MI within 2 years, with no other adverse events • At 2 years, stable late-loss and percent stenosis; stent was bioabsorbed MLD % stenosis Post-procedure 6 months Ormiston JA, et al. Lancet 2008;371:899-907 Serruys PW, et al. Lancet 2009;373:897-910

More Related