Cavity Test Results : TB9AES002 & TB9NR002

Cavity Test Results : TB9AES002 & TB9NR002. TB9AES002 (aka AES002) : dressed cavity that received light EP, after limited in 3 vertical tests to 20MV/m (hard quench) TB9NR002 : first cavity fabricated by Niowave / Roarke to be processed/tested.

lindley
Download Presentation

Cavity Test Results : TB9AES002 & TB9NR002

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Cavity Test Results : TB9AES002 & TB9NR002 TB9AES002 (aka AES002) : dressed cavity that received light EP, after limited in 3 vertical tests to 20MV/m (hard quench)TB9NR002 : first cavity fabricated by Niowave/Roarke to be processed/tested Cavity Mtg. 11/10/2010 J. Ozelis

  2. Early FE onset (9 MV/m), processed away. FE returned at 18MV/m. Limited by FE-induced quench at 27.3MV/m. LF Q0 1.9 x 1010 (“hump”), strong Q0 drop due to FE loading at 20MV/m. Improvement from previous 19.8MV/m (hard) quench limit, but FE much worse, and overall Q0 is lower (LF and HF).

  3. First N/R cavity to be tested. Full processing at FNAL/ANL. Quench limited to 28.5 MV/m (with Q0 there 1.2 x 1010). Also good LF Q0 (2.1 x 1010), no FE. At 1.8K, Q0 improves by 30-40% (typical).

  4. Mode meas & OST data indicate cell #2 as limiting cell. Others do better : 30– 43MV/m. Recent re-tests w/ thermometry and optimized placement of OST’s indicate cells 1 and 2 are limiting performance at the 28-29 MV/m level.

  5. Residual surface resistance ~7nW.

  6. Some observations about TB9NR002 quenches : • At 2.0K… • In the p-mode, see an obvious quench signal on cell#1, sensor #5, at 2.0K, 28.5 MV/m • In the 8p/9 mode (cells 1/9), again see quench signal on cell#1, sensor #5, at 2.0K (as expected), 29.3 MV/m. • In the 3p/9 mode (cells 2/8) see quench signal on cell #2, sensor #5 (same azimuthal position as quench in cell #1) at 27MV/m. • In the 2p/9 mode (cells 3/7) see quench on cell #2, sensor #5 again. Cell 3/7 field is ~39MV/m at this point, cell 2 field is? (27-28 MV/m based on 3p/9 data).

  7. Now at 1.8K(-ish)… • In the p-mode (quenching at same field ~ 29MV/m, 1.81K), see only general RF heating on cells 1 &2, OST’s seem to indicate quench location is ~0.5m above (cells 8 or 9 ?). • In the 3p/9 mode (cells 2/8) see a quench in cell #2, sensor #5 (as at 2.0K), at ~27-29 MV/m, 1.77K. • Going up to 1.85-1.86K, again in p-mode see quench signal in cell #1, sensor #5, at the nominal 28MV/m field level. • Summary : • Quench locations in cells 1, 2, and 8(9), at field levels of 27-29 MV/m. • Some temperature dependence of quench location observed. • Quenches in cells 1 & 2 appear to be along same azimuthal position.