1 / 15

Concrete Slab Quality Requirements

Concrete Slab Quality Requirements. Who Controls Concrete Quality. Polishing contractors have to perform work on a concrete floor slab in which they had no control over design and placement quality

ken
Download Presentation

Concrete Slab Quality Requirements

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Concrete Slab Quality Requirements

  2. Who Controls Concrete Quality • Polishing contractors have to perform work on a concrete floor slab in which they had no control over design and placement quality • Design professionals have to be proactive and see that certain requirements are included in concrete specification

  3. Pre-Concreting Meeting Polishing contractor should participate in the meeting

  4. Flat Subgrade • Should be uniformly graded flat and level • Subgrade rises and depressions can cause variations in concrete slab thickness thus causing color differences because of differential curing and drying

  5. Vapor Retarder • Product should comply with ASTM E 745 and have permeance of 0.01 perms after conditioning according to ASTM E 154 Section 7.1 • Installation should comply with ASTM E 1643

  6. Concrete Mix Design • Consistent source for materials • W/C of 0.45 • 3,500 psi • Normal weight aggregates • Not air-entrained • No replacements for portland • cement

  7. Construction Joints and Patches • Strategically locate construction joints to avoid mismatching segments • Patch finish will not match surrounding surfaces

  8. Steel Column Baseplates Be aware of design of concrete at steel column baseplates

  9. Placing • Comply with ACI standards • End of chute or tremie not more than 6 ft above point of placement • Monitor and control: • - Concrete temperature • - Water added at site

  10. Flatness and Levelness

  11. Finishing • Specific procedures recommended • Steel trowel surface in three passes without burning surface • Do not dust surface • with dry portland • cement or sand • to accelerate curing • and drying

  12. Curing and Drying • Evaporation control • Wet-curing method

  13. Environmental Benefits

  14. Environmental Benefits • Polished concrete does • not have to be • removed or replaced; • it can be “forever” • Light reflective • Durable • Flooring covering products not needed • Low maintenance requirements

  15. D+D Specifiers Series Questions WALTER SCARBOROUGH CSI CCS CCCA SCIP AIA wscarborough@hbig.us 214.491.7385 Sponsored by