LWL - Verkabelung Geb. 55. 12 fasrig Schrank 4 -> Geb.54. D/3 0 III. D/3 0 54. D/3 1 West. D/3 1 54. 2 Fasern Reserve. ST. 11. 5. 6. 10. 12. 1. 3. 7. 8. 2. 4. 9. 11 12 13 14 15 16 17 18 19 10. 12 fasrig nach

june
Download Presentation

LWL - Verkabelung Geb. 55

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. LWL - Verkabelung Geb. 55 12 fasrig Schrank 4 -> Geb.54 D/3 0 III D/3 0 54 D/3 1 West D/3 1 54 2 Fasern Reserve ST 11 5 6 10 12 1 3 7 8 2 4 9 11 12 13 14 15 16 17 18 19 10 12 fasrig nach Geb. 54 grün 4 FSMA 1 2 3 4 5 6 7 8 9 10 KRYK FDDI / B FDDI --> Geb. 30 Von Hirschmann Y 2 K = Kupplungsnummer 1 2 3 1 2 3 = Fasernnummer Siemens H 1 S P S HeraM2 12 fasrig nach Geb. 54 schwarz 9 FSMA (MKS4) 2 4 5 6 Y2K nach Halle III 7 8 9 10 3 Nach CentreCom 3605 West 501 Profibus MKK D/3 1 III 12 fasrig von Geb. 2b ST 3 4 5 6 7 8 10 11 2 9 12 MKK Lab 1 D/3 0 West HERMES HERA B 12 fasrig nach Halle West 501 ST 11 5 6 10 12 3 7 8 2 4 9 1 Reihe 15 Ethernet  54 Sternkoppler von LANPlex 2500 -> nach West 501 Sternkoppler ZDV KRYK FDDI / A 2 1 4 großeDämpfung, schlechteFasern 5 6 23 24 3 FSMA 0 Verteilerleiste ohne Kabel 3 4 1 2 5 6 7 8 9 10 freie Kupplung freie Kupplung freie Kupplung freie Kupplung Verteiler II von Geb. 2b Verteiler I von Geb. 54 1 grau 4 fasrig nach Geb. 54 6 fasrig nach 2b 6 schwarz 0.0 HEAX01 ST Verteilerleiste ohne Kabel 7 6 8 9 4 Urbschat -MKS 2- 07.02.2002 2 3 5 10 1 22 21

  2. 3 10 1 2 3 4 5 6 7 8 9 LWL - Verkabelung Geb. 54 ST D/3 1 54 D/3 1 West D/3 0 III D/3 0 54 12 fasrig von Geb.55 Schrank 4 2 Fasern Reserve 11 5 6 10 12 1 3 7 8 2 4 9 1 3 2 4 1 Optabal 4 fasrig von Geb.55 Vert.1 (grau) 1 2 3 4 großeDämpfung, schlechteFasern Stern Y2K Optabal Optabal Profi-Bus 1 3 2 4 1 2 4 2 3 2 x 4 fasrig nach Halle West 501 Reihe 19 1 2 3 4 5 6 7 8 FDDI ---> BKR FSMA KRYK FDDI B 13 14 11 12 17 16 18 15 2 Fasern Reserve 4 12 fasrig von Geb.55 (grün) 1 2 3 4 5 6 7 8 9 10 LANplex A B Y2K defekt 2 Fasern Reserve 5 12 fasrig nach Halle III (schwarz) FSMA D/3 0 III FSMA 2 Fasern Reserve 9 12 fasrig von Geb.55 Reihe 2 10 Y2K 1 2 3 4 5 6 7 8 9 Nach CentreCom 3605 West 501 H 1 Siemens S P S HeraM2 (MKS4) FSMA 10 2 Fasern Reserve 12 fasrig nach Halle West 501 Reihe 18 10 5 6 7 8 9 1 2 3 4 D/3 1 West DEC Repeater 90 FA West 501 Reihe 23 Urbschat -MKS 2- 07.02..2002 1 2

  3. LWL - Verkabelung Hera-Halle West 501 Von LANPlex 2500 Geb.55 -> Hirschmann Sternkoppler 501 D/3 0 West ST HERA B HERMES 15 12 fasrig von Geb 55 Reihe 1 3 4 5 6 7 8 10 11 1 2 9 12 ST HERA B 12 fasrig Raum 201 Reihe 1 16 1 2 3 4 5 6 7 8 9 10 Nach CentreCom 3605 West 501 ST Hera M2 Decrepeater H1 S P S 12 fasrig von Geb54 Reihe 5 10 Ethernet 30a 18 1 2 3 4 5 6 7 8 9 10 FDDI ---> BKR Reihe 9 9 +10 Profibus MKK 2 x 4 fasrig von Geb54 Reihe 2 ST 2 3 1 2 1 3 4 2 3 4 19 6 7 8 9 10 5 1 2 3 4 ST 22 5 7 8 9 10 3 4 2 1 ST 24 5 6 7 8 9 10 3 4 2 1 ST 1 2 3 4 5 6 7 8 9 10 Urbschat -MKS 2- 07.02.2002

  4. LWL - Verkabelung Geb. 28 Halle III Netzwerkschrank Kontrollraum Ethernet Modul LISA 11 ST 12 fasrig von Diag ACC4 10 1 2 3 4 5 6 7 8 9 2x12 fasrig nach 2b SC . . . . . . . . . . . 1 5 8 9 10 2 3 4 6 7 12 24 11 1+2 Katalyst 3 LANPlex 4 TS 12 D/3 0 III Container 2a ST 7 6 (12) fasrig nach VME Rack 1 2 3 4 5 6 7 8 9 10 D/3 0 III 5 ST 12 fasrig von 54 an der Wand defekt 1 2 3 4 5 6 7 8 9 10 Sedac-LWL Y2K 2xX-Term D3 Anwendung LANplex 2500 Urbschat -MKS 2- 07.02.2002

  5. noch LWL - Verkabelung Geb. 28 Halle III Sedac-Crate FSMA 8 4 fasrig nach Partikel 3 4 2 1 zähler FSMA 12 fasrig von Kontroll- raum 7 1 2 3 4 5 6 7 8 9 10 Partikelzähler ST 8 4 fasrig von Sedac Crate 1 2 3 4 LWL / Koax Franzosen Urbschat -MKS 2- 21.10.1999

  6. Netzwerktopologie MKS2 FDDI Link DEC-Hub Rechnerraum “ Kontrollraum 1 x 100BaseT “ LANplex 2500 Geb. 54 B A DEC switch 900EF A B Geb. 28 Subnet .112 DEC-Hub LANplex 2500 Geb. 30 C o n c 9 e 0 n 0 t M r X a t o r A A B 3 Alpha- rechner 1 x Dec-Hub Rechnerraum R105 1 x Dec-Hub Terminalraum R105 1 x Dec-Hub Entwicklung R104 Isoliert D/3 Netz Y2K B CoreBuilder Geb 55 55 1 x 100BaseT 3com switch 1 x Dec-Hub Inhouse Ethernet B A LANplex EPICS CoreBuilder Geb. 55 B A Geb 55 A B 2 b LANplex GATEWAY Geb. 2b Ethernet Geb 47b Geb 50 Hirschmann-HUB Geb 50 Referenzmagnet KRYK B A HERA West 501 Reihe 15 3/4 (LanPlex Router Raum 201) Urbschat -MKS 2- 21.10.1999 Rechenzentrum 3/4

  7. LWL - Verkabelung Geb. 55 Schrank # 4 ST MKK 12 fasrig nach HERA West 501 10 11 12 1 2 3 4 5 6 7 8 9 ST D/3 1 54 D/3 0 54 D/3 0 III D/3 1 West 12 fasrig nach Geb. 54 10 11 12 1 2 3 4 5 6 7 8 9 ST 12 fasrig nach HERA West 501 10 11 12 1 2 3 4 5 6 7 8 9 ST 12 fasrig nach HERA West 501 10 11 12 1 2 3 4 5 6 7 8 9 ST 12 fasrig nach Geb. 47b 1-6 10 11 12 1 2 3 4 5 6 7 8 9 CTA 2x12 fasrig nach 2b . . . . . . . . . . . 1 5 8 9 10 2 3 4 6 7 12 24 11 D3 1 III Urbschat -MKS 2- 15.07.2002

  8. LWL Verbindungen von den HERA-Hallen zum BKR von MKI HERA-Halle Nord F01-22-05 F01-22-06 BKR A11-03-01 A11-03-02 ER1 HN BKR A11-03-03 A11-03-04 HERA-Halle Ost F01-22-05 F01-22-06 HO ER1 BKR A11-03-05 A11-03-06 HERA-Halle Süd F01-24-05 F01-24-06 HS ER1 BKR A11-03-07 A11-03-08 HERA-Halle West F01-23-09 F01-23-10 HW ER1 Urbschat -MKS 2- 07.03.1997

  9. Coax über 401 Verteiler Rack 14  MHF R.607 . . Halle West Coax MKK R.809 Geb.54 LWL LWL . Y2K-Netz . 3 com Geb.55 3 com Geb.55 Urbschat -MKS 2- 21.02.2001 FDDI