An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MEMORY MODE The HAAS ControlSeries

  2. SLIDE LEGEND PRESS THREE TIMES TO GET TO THIS PAGE (Continued on next slide) Note: ACTIONS To advance through the presentation click on your left mouse button or press <ENTER>. To exit press <ESC>. KEYS INSTRUCTIONS INFORMATION OTHER INFORMATION

  3. MEMORY MODE This module is intended to provide you with a familiarization of the Memory Mode on the Haas Control

  4. Here is where you find the Memory Buttons

  5. Memory Buttons MEMORY: SINGLE BLOCK: DRY RUN: OPTIONAL STOP: BLOCK DELETE: Pressing the memory button on the control will display the current program for running when you press <CYCLE START>. The current program is the one that has been selected in LIST PROGRAMS.

  6. Memory Button: MEMORY Button: The selected program is ready to run. Press <CYCLE START> PROGRAM (MEM) O91002 N00000 G01 Z-0.0337 F7. ; G01 X-0.5687 Y-0.9857 ; G01 X-0.2275 ; G01 X0.1314 Y0.2275 ; G01 X-0.2275 ; G01 X0.1314 Y0.2275 ; G01 X-0.7835 ; G01 X0.1314 Y0.2275 ; G01 X0.7835 ; G01 X-0.5687 Y-0.9857 ; G01 X-0.2275 ; G01 X0.1314 Y0.2275 ; G01 X-0.7835 ; G01 X0.1314 Y0.2275 ; G01 X0.7835 ; G01 X0.3058 Y0.5308 ; G01 X0.7835 ; G03 X0.2475 Y0.5508 R0.02 ; F4 FOR PROG REVIEW O12345 (MILL LAB PROG 1) ;

  7. Single Block Button: SINGLE BLOCK Button: Used like a toggle switch. The control will execute one block of program then stop; every press of <CYCLE START> will execute one more block. With Setting 104: Jog Handle to Single Block ON Press <CYCLE START> Then rotate the Jog Handle CCW to run the program. Each click of the handle will execute 1 block. CW = Feed Hold PROGRAM (MEM) O91002 N00000 G01 Z-0.0337 F7. ; G01 X-0.5687 Y-0.9857 ; G01 X-0.2275 ; G01 X0.1314 Y0.2275 ; G01 X-0.2275 ; G01 X0.1314 Y0.2275 ; G01 X-0.7835 ; G01 X0.1314 Y0.2275 ; G01 X0.7835 ; G01 X-0.5687 Y-0.9857 ; G01 X-0.2275 ; G01 X0.1314 Y0.2275 ; G01 X-0.7835 ; G01 X0.1314 Y0.2275 ; G01 X0.7835 ; G01 X0.3058 Y0.5308 ; G01 X0.7835 ; G03 X0.2475 Y0.5508 R0.02 ; F4 FOR PROG REVIEW O12345 (MILL LAB PROG 1) ; SINGBK Excellent for checking out your program when in Graphics Mode

  8. Dry Run Button: PROGRAM (MEM) O91002 N00000 DRY RUN Button: Used in Memory or MDI mode. Used to check a program using reduced speeds and feeds. All rapids and feed rates are run at the rate selected with the JOG speed keys. Press Select the speed. Press <HAND CNTL SPIN> Adjust with Jog Handle G01 Z-0.0337 F7. ; G01 X-0.5687 Y-0.9857 ; G01 X-0.2275 ; G01 X0.1314 Y0.2275 ; G01 X-0.2275 ; G01 X0.1314 Y0.2275 ; G01 X-0.7835 ; G01 X0.1314 Y0.2275 ; G01 X0.7835 ; G01 X-0.5687 Y-0.9857 ; G01 X-0.2275 ; G01 X0.1314 Y0.2275 ; G01 X-0.7835 ; G01 X0.1314 Y0.2275 ; G01 X0.7835 ; G01 X0.3058 Y0.5308 ; G01 X0.7835 ; G03 X0.2475 Y0.5508 R0.02 ; DRY RUN SPEED 1. O12345 (MILL LAB PROG 1) ; DRYRUN

  9. Optional Stop Button: OPTIONAL STOP Button: When an M01 command is encountered in the program, then a program stop will be executed. Press <CYCLE START> to continue. PROGRAM (MEM) O91002 N00000 G01 Z-0.0337 F7. ; G01 X-0.5687 Y-0.9857 ; G01 X-0.2275 ; G01 X0.1314 Y0.2275 ; G01 X-0.2275 ; G01 X0.1314 Y0.2275 ; G01 X-0.7835 ; G01 X0.1314 Y0.2275 ; M01 G01 X0.7835 (Optional Stop); G01 X-0.5687 Y-0.9857 ; G01 X-0.2275 ; G01 X0.1314 Y0.2275 ; G01 X-0.7835 ; G01 X0.1314 Y0.2275 ; G01 X0.7835 ; G01 X0.3058 Y0.5308 ; G01 X0.7835 ; G03 X0.2475 Y0.5508 R0.02 ; F4 FOR PROG REVIEW O12345 (MILL LAB PROG 1) ; OPTSTP

  10. Block Delete Button: BLOCK DELETE Button: When a program block begins with a slash (/) it will be ignored (i.e., that program block will not execute). PROGRAM (MEM) O91002 N00000 G01 Z-0.0337 F7. ; G01 X-0.5687 Y-0.9857 ; G01 X-0.2275 ; G01 X0.1314 Y0.2275 ; G01 X-0.2275 ; G01 X0.1314 Y0.2275 ; G01 X-0.7835 ; G01 X0.1314 Y0.2275 ; /G01 X0.7835 (Block Delete) ; G01 X-0.5687 Y-0.9857 ; G01 X-0.2275 ; G01 X0.1314 Y0.2275 ; G01 X-0.7835 ; G01 X0.1314 Y0.2275 ; G01 X0.7835 ; G01 X0.3058 Y0.5308 ; G01 X0.7835 ; G03 X0.2475 Y0.5508 R0.02 ; F4 FOR PROG REVIEW O12345 (MILL LAB PROG 1) ; BLKDEL

  11. Prepared by Haas AutomationTraining DepartmentOxnard, CA 93030