A Self-adjusting Scheme to Determine Optimum RBB by Monitoring Leakage Currents

A Self-adjusting Scheme to Determine Optimum RBB by Monitoring Leakage Currents. Nikhil Jayakumar* Sandeep Dhar $ Sunil P. Khatri* $ National Semiconductor, Longmont,CO. *Texas A&M University, College Station, TX. Introduction.

jacquesj
Download Presentation

A Self-adjusting Scheme to Determine Optimum RBB by Monitoring Leakage Currents

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. A Self-adjusting Scheme to Determine Optimum RBBby Monitoring Leakage Currents Nikhil Jayakumar* Sandeep Dhar$ Sunil P. Khatri* $National Semiconductor, Longmont,CO. *Texas A&M University, College Station, TX.

  2. Introduction • Leakage power is expected to exceed dynamic power consumption in the near future. • Existing techniques to reduce leakage • Static • High VT power gating switches (MTCMOS, HL). • Dual VT assignment (DUET). • Dynamic • DTMOS, SCCMOS. • Reverse Body Biasing (RBB). • RBB reduces leakage (body effect) but if RBB istoo high, leakage can actually increase due toother leakage components.

  3. Leakage Components • Sub-threshold leakage • Drain -> Source • Gate leakage • Drain -> Gate / Source -> Gate • Drain -> bulk leakage • Bulk Band to Band Tunneling (BTBT) • Surface BTBT (Gate Induced Drain Leakage - GIDL) • Reverse biased PN junction current

  4. Effect of RBB on Leakage • Sub-threshold decreases exponentially with Vt, which increases with RBB. • Gate leakage (drain-gate) does not change appreciably with RBB. • At RBB BTBT dominates GIDL. • Mainly, sub-threshold leakage & BTBT change with RBB. • Sub-threshold leakage decreases with RBB,while BTBT increases with RBB. • Hence there exists an optimum RBB point for minimum leakage.

  5. Variation in Leakage Components with RBB Plot of leakage current components with RBB as measured on a large NMOS device on a test-chip at 25oC

  6. Optimal RBB Determination – Previous work • In “Optimal Body Bias Selection for Leakage Improvement and Process Compensation over Different Technology Generations” – C. Neau and K. Roy (ISLPED03), a circuit is presented to help find the optimal RBB. • Based on the assumption that sub-threshold leakage is negligible compared to BTBT for stacked devices. • Claims that optimal RBB is at point at which leakage through 2 stacked devices is equal to half the leakage through a single leaking device. • This assumption underestimates the sub-threshold leakage component.

  7. Optimum RBB • Point A marks the optimum RBB point as would be suggested by the previous scheme. • Point B marks the actual optimum RBB. • This work proposes a circuit which dynamically finds point B. Leakage current measured for a large NMOS device and 2 large NMOS devices in series on a 0.13μtest-chip at 25oC

  8. Leakage Monitoring and Self-adjusting Scheme • The Leakage Monitoring Scheme consistsof 3 components • A Leakage Current Monitor (LCM). • This leakage monitor is designed to work over a wide range of leakage currents. • A Digital Block to interface with the LCM and control the body-bias voltage. • A programmable body bias voltage generator controlled by the Digital Block. • We discuss the first 2 blocks.

  9. Leakage Monitoring and Self-adjusting Scheme • The Leakage-Monitoring scheme is based on measuring the time taken for a leaking device to discharge (or charge) a capacitive load. • At the heart of this is the LCM.

  10. The Leakage Current Monitor (LCM) • Shown here: LCM for NMOS leakage. • Node Nchk is initially precharged. • Leakage through a representative device ML is measured by sampling node Nchk at regular intervals and seeing when (number of sampling periods after which) the node Nchk is discharged. • A capacitor bank and a small gate bias are provided to increase or decrease rate of discharge of the node. • Allows the LCM to work over a wide range.

  11. We start at a point on the curve where leakage will decrease with RBB We then move along the curve till … we hit the point at which leakage starts increasing Operation of the Scheme • The Digital Block measures the time taken for the leaking device in the LCM to discharge (charge) the monitored node in the LCM.

  12. Salient features of our Scheme • Low power • Only about 11.4μA at 1.2V and 125oC for 0.13 μm TSMC process • Leakage current measurement based on time taken to discharge a node. • Uses same leakage monitoring cell to handle large variations of leakage currents • Capacitor bank and switch-able gate bias used to adjust range.

  13. Area required • Layout (standard cell based) done for the leakage monitors for PMOS and NMOS. • Height of standard cell = 3.285μ. • Width of cell for • Pulse generator = 38.22μ (126 μ2) • LCM nmos = 77.87μ (256 μ2) • LCM pmos = 86.41μ (284 μ2) • Total area approx = 665 μ2

  14. Conclusion • Reverse body biasing is a useful technique toreduce leakage. • However, if the RBB is too high, the leakagecurrent may inadvertently increase. • The optimum RBB point can vary with processand temperature variations. • Hence a scheme such as ours that can dynamically find the optimum RBB point can help greatly. • Also the scheme itself does not consume veryhigh power and it has a very modest silicon area requirement.

  15. Questions ?