1 / 36

Aritech Seismic detectors VV600 Plus & VV602 Plus

Aritech Seismic detectors VV600 Plus & VV602 Plus. VV600 Plus & VV602 Plus. The VV600 Plus series is the next generation development based on proven high technology electronic processing with excellent secure detection without false alarms. . Two different detector models. VV600 Plus

hollye
Download Presentation

Aritech Seismic detectors VV600 Plus & VV602 Plus

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Aritech Seismic detectors VV600 Plus & VV602 Plus

  2. VV600 Plus & VV602 Plus The VV600 Plus series is the next generation development based on proven high technology electronic processing with excellent secure detection without false alarms.

  3. Two different detector models • VV600 Plus • for protection of safes, vaults, steel cabinets etc. • VV602 Plus • for protection of public applications like ATM’s (cash dispensers) and night safe deposit boxes.

  4. New features & improvements • Upgraded electronics, 100% SMT, and detection algorithms • New fresher look of the cover. The cover is only mounted with one screw. • New drill protection covers the whole detector. • New test system.

  5. New features & improvements • Extremely low current consumption, 25mA  8mA • Only one micro switch for both tamper and pry-off protection. • Two spare screw terminals. • Improved tamper protection at the cable inlet.

  6. Function & applications VV600/602 Plus

  7. First back to basic • Acceleration = gravity = m/s² • Amplitude = signal strength • Frequency = Hz = Periods/sec. = 1 Hz/sec = 1 kHz

  8. Frequency range between 6 - 20 kHz Signal Ultrasonic detectors Detection area Frequency 6 kHz 20 kHz

  9. Signal characteristics of a true break-in attempt • Explosive means - high amplitude, short signal duration • Mechanical destruction & rotating devices - moderate to high amplitude, long signal duration • Thermal devices - low amplitude, long signal duration

  10. Principles of operation • Piezo electric sensor convert vibrations (acceleration) to electrical signals • Advanced three channel signal processing • Signal processor will analyse the following three parameters simultaneously: • Signal strength (amplitude) • Signal frequency • Signal duration

  11. Schematic diagram of VV600 Plus

  12. Integration channel Will detect all kinds of rotating and thermal tools Will not detect back-ground noises Five different sensitivity settings Will reset gradually to base level Frequency = 6-20 kHz Acceleration = >0,1 m/s² Time = max 40 sec VV600 Plus signal processing channels Amplitude Alarm level Signal duration

  13. VV600 Plus signal processing channels • Counting channel • Detects all mechanical attack devices like sledge, hammer, hydraulic jack etc. • Will give an alarm after 5 pulses • Reset time 3 min • The sensitivity is pre-set • Frequency = 1-20 kHz • Acceleration = >10 m/s² • Time = 5 true pulses Amplitude Alarm Signal duration

  14. VV600 Plus signal processing channels • Explosion channel • Detects all explosions • Trigger an alarm after a pre-set limit • 100 x lower sensitivity than a shock sensor • Frequency = 1-20 kHz • Acceleration = > 400 m/s² • Time = 20 Millie sec Amplitude Alarm level Signal duration

  15. VV602 Plus for special applications • The objects are frequently used by the public, even 24 hours a day. • The objects are creating vibrations and knockings by their normal operation.

  16. Schematic diagram of VV602 Plus

  17. Low integration channel Will detect thermal, rotating and mechanical tools Alarm will not be triggered by internally generated vibrations of the ATM e.g. printer, note counter and note dispenser Will reset by an interruption of the signal Frequency = 6-20 kHz Acceleration = >0,15 m/s² Time = 5-15 sec VV602 Plus signal processing channels Amplitude Alarm level Signal duration

  18. High integration channel Will detect rotating and thermal attack type tools Alarm will not be triggered by internally generated vibrations of the ATM 4 x lower sensitivity than the low integration channel Integrates only signals that continues after 5 sec. Frequency = 6-20 kHz Acceleration = > 1 m/s² Time = 5-15 sec VV602 Plus signal processing channels Amplitude Alarm level Signal duration 5 sec

  19. VV602 Plus signal processing channels • Explosion channel • Detects all explosions • Trigger an alarm after a pre-set limit • 100 x lower sensitivity than a shock sensor • Frequency = 1-20 kHz • Acceleration = > 400 m/s² • Time = 20 Millie sec Amplitude Alarm level Signal duration

  20. Why should you use a seismic detector? • No safe or strong room is impenetrable. • Using the VV600/602 Plus gives a 24 hour surveillance without restricting the activity around the protected object. • Early warning gives more time for counter actions. • Early warning will reduce costs for an attack in more than one way.

  21. Banks and Post offices: Military installations: Pharmacies, Hospitals: Museums, Jewellers shops: Offices: Vaults and safes ATM Night safe deposit boxes Arms & munitions stores Steel gates and doors Drug cabinets Display cases & safes Data and filing cabinets Areas of application

  22. Installation & planning guide-lines for VV600/602 Plus

  23. Wiring diagram VV600/602 Plus

  24. Detection range of the VV600/602 Plus

  25. Planning a vault protection with VV600 Plus • General rule; one detector on each wall, floor and ceiling inside the vault and one detector on/ inside the vault door. • It is recommended to do a layout plan to define the location of each detector.

  26. Protection of a vault • Using a recess mounting box VM602P ensures the best coverage, as the detector is anchored in the reinforcement bars of the concrete.

  27. Planning protection of a safe or filing cabinet with VV600 Plus • Most of the attacks against safes are aimed at the door and the locking mechanism. • The hinges reduces the signal between the door and the body. • For highest security: • one detector on the door • one detector on the body

  28. Protection of a safe • Moveable mounting plate VM651P • Detector on the night position plate makes it impossible to opened the door. • Keyhole protection kit VM652P • Stops the intruder from inserting stolen keys and explosives.

  29. Planning protection of ATM’s & night safe deposit boxes with VV602 Plus • Always use the VV602 Plus for public applications to avoid false alarms. • Most attacks are aimed at the door and the dispenser opening. Detectors

  30. Testing system • VT705P - built in test transmitter • Daily test of the detector provides the highest level of security. • Mounted on its own mounting bolt, enables test of the detector’s electronics and its physical contact to the protected object. • VT610P - hand held tester • Can be used to test permanent systems and to verify the installation.

  31. Two ways of testingwith the test transmitter • Test disabled (factory setting)  • Internal test of the detector’s electronic  • Function test of the detector and its physical contact to the protected object with VT705P 

  32. Control & function test • Control function and mounting of the detector by using a potentiometer and the hand-held tester VT610P

  33. Upgraded accessories • Complete range of accessories for all kinds of applications.

  34. Planning guide-lines • Don’ts…. • Don’t assume that covered concrete walls are free of cracks. • Don’t install sensors permanently before determine sensitivity settings and ambient noise level. • Don’t install the detector on unproved masonry surface without contacting Aritech. • Don’t mount the detector on rough surfaces, sand first. • Don’t allow the test transmitter VT705P to have contact with the mounting plate or the detector.

  35. Summary • Will detect all known methods of attacks • Will not react to normal background noises • Will detect any attack within a minimum of 4 meter radius • Sensitivity can be set in five steps for optimum performance in any installation • High immunity against RFI and EMC • Complete line of accessories • Easy installation

  36. Thank you for your attention. Any questions?