1 / 1

The BCM Microarray Core Facility: Closing the Next Generation Gap

Isolate mRNA and Fragment. 1-10 m g of Total RNA. T. A. A. T. 1st and 2nd strand cDNA synthesis. Ligate Adapters. Sequencing on GAIIx. Enriched cDNA Library by PCR. Cluster Generation on Flow Cell. Size selection and gel purification.

garin
Download Presentation

The BCM Microarray Core Facility: Closing the Next Generation Gap

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Isolate mRNA and Fragment 1-10 mg of Total RNA T A A T 1st and 2nd strand cDNA synthesis Ligate Adapters Sequencing on GAIIx Enriched cDNA Library by PCR Cluster Generation on Flow Cell Size selection and gel purification The BCM Microarray Core Facility: Closing the Next Generation Gap Alina Raza1, Mylinh Hoang1, Gayan De Silva1, Laura Liles1, Carl Broadbent1, Yanglong Mou1, Lisa D. White1,2 1Microarray Core Facility and Dept. Molecular & Human Genetics, 2Dept. Molecular & Cellular Biology, Baylor College of Medicine, Houston, TX USA INTRODUCTION NEXT-GENERATION SEQUENCING • APPLICATIONS AVAILABLE • Gene expression and alternative splicing (mRNA-Seq) • Protein-nucleic acid association profiling/epigenetics (ChIP-Seq) • Sequencing targeted genomic regions (DNA-seq) • Small RNA discovery (small RNA-Seq) • De novo genomic DNA sequencing • 36, 50, or 75 cycle, single-end or paired end The Microarray Core Facility (MCF) at Baylor College of Medicine provides investigators with access to a variety of state-of-the-art technologies and approaches that will enhance discovery for their genomic research. We house instrumentation supporting Affymetrix, Agilent, NimbleGen, Luminex, and Illumina platforms. The MCF provides expertise in the following applications: gene expression profiling using arrays, array comparative genomic hybridization (aCGH), SNP genotyping, and next-generation sequencing applications including RNA-seq, ChIP-seq, Targeted genomic resequencing, miRNA-seq, and de novo sequencing. In addition, our lab offer services for sample quality check and provides access to a 150K cDNA clone repository, for those that are interested in verifying results from gene expression experiments or any other application requiring cDNA clones.  QUALITY CONTROL LIBRARY QUALITY: PAIRED-END SEQUENCING AGILENT BIOANALYZER BIO-RAD EXPERION The combination of read-length and paired-end flexibility allows for high quality genomic sequencing applications. Illumina’s sequencing chemistry supports 100+ bp single-reads, short- and long-insert paired-end reads for whole-genome sequencing and resequencing, SNP discovery, identification of copy number variations and chromosomal rearrangements. Extensive QC steps are undertaken throughout sample processing. Total RNA quality is initially checked using the Agilent Bioanalyzer. Genomic DNA, PCR fragments, and cDNA are checked using either 2% agarose gel electrophoresis or the Agilent Bioanalyzer. Internal sample processing QC steps include testing library size and yield using either the Agilent Bioanalyzer or the Bio-Rad Experion instrument. Library size must be checked before proceeding to the Cluster Station to ensure appropriate clusters will grow on the flowcell. The two images above illustrate our comparison of the Agilent Bioanalyzer and the Bio-Rad Experion resulting in essentially no differences. Both instruments appear to work equally well at measuring size, quality, and concentration of the sequencing libraries. RESOURCES The MCF is a full service facility offering exemplary processing in applications ranging from transcriptomic profiling to specialized DNA analyses. Using Affymetrix, Agilent, and Nimblegen array technology we enable researchers to monitor genome-wide expression profiles and answer questions about gene regulation including investigations of alternative splicing and miRNA profiling.  Our mid-range throughput technology utilizes the Luminex Bead System to measure multiplexed (3-30 genes) gene expression in a 96-well plate format. We also offer QPCR analyses utilizing the SA Biosciences SuperArray platform for gene expression profiling. Chromosomal copy number changes and CNV analyses of genomic DNA are performed using Agilent’s aCGH/CNV and Affymetrix SNP Arrays. After the first read, the clusters are modified to regenerate the template for the paired read. SAMPLE WORKFLOW for mRNA-seq LIBRARY QUANTIFICATION: qPCR is used to quantify libraries to generate the accurate number of reads on the sequencer. Samples are measured against a control of known concentration, which is run with the samples on every flowcell. • Sample Quality • Agilent Bioanalyzer • Bio-Rad Experion • NanoDrop • Gel Electrophoresis • Gene Exp. Profiling • mRNA • Affymetrix • Agilent • NimbleGen • SuperArray • Luminex/Panomics • qPCR • microRNA • Luminex FlexmiR • Agilent • Affymetrix • qPCR • Exon/alternative splicing • Affymetrix • qPCR • DNA Analyses • SNP Genotyping • Affymetrix SNP 6.0 • Luminex xTAG • qPCR • ChIP-on-Chip/epigen. • Agilent • Affymetrix • Nimblegen • aCGH • Agilent • NimbleGen • Affymetrix SNP 6.0 • Clone Repository • Data Analysis CONCLUSIONS Using Illumina GenomeStudio software to analyzer mRNA-seq reads, sequence tables are generated providing information on the position of the sequence within the chromosome. Information on SNPs present in a given sample are also provided in a table describing the position of the SNP, the reference base and the base called. • Illumina’s fast and cost-effective technology gives researches tremendous amounts of high-quality data to analyze in many applications • Applications include de novo sequencing, resequencing of whole genomes and target DNA regions (single and paired end reads) New Illumina Genome Analyzer IIx sequencing

More Related