1 / 5

Pad Chamber +MuTr station #1 for Muon Trigger Upgrade

Pad Chamber +MuTr station #1 for Muon Trigger Upgrade. 10/27/2003 Muon Trigger Upgrade meeting. Position Resolution using MuTr Cathode and Anode.

fleur-glass
Download Presentation

Pad Chamber +MuTr station #1 for Muon Trigger Upgrade

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Pad Chamber +MuTr station #1 for Muon Trigger Upgrade 10/27/2003 Muon Trigger Upgrade meeting

  2. Position Resolution using MuTr Cathode and Anode MuTr station#1 has 3 anode gaps. Each gap has a plane with cathode strip 90 degree to anode and a plane with strip 11.25 or 6 degree to anode. Width of cathode strip is 0.5cm, anode spacing is 1.0cm. Annode charge fire 4-6 strips from simulation with mom>=4GeV/c. Hits position is determined by the intersection point betweem wire and cathode strips.

  3. LUT between MuTr#1/PC2/Symset Then we do look-up among MuTr#1/pc2/symset. Single muons with mom=4-10GeV/c is passed through PISA. Only multiple-scattering and energy loss are turned on. Here shows only tile size: MuTr#1/10cm, PC2/30cm.

  4. Rejection and Efficiency with (:MuTr#1/pc2) cut and MuTr#1/PC2/uIDLL1 LUT(1.LUT is satisfied in BOTH directions) (1). PC1 is in front of station #1. Tile size PC1(10cm), PC2(20cm). Perfect resolution (2). MuTr#1. PC2 resolution is perfect. Mutr#1 tile size 10cm/PC2 tile size 30cm • The LUT of MuTr#1/PC2/symset is low, i.e. 76%. Need to find the reason. • No field betweem nosecone and station#1, therefore the different at ()<1 is due to the position resolution in MuTr#1. • In other angle cut, rejection in (2) is large than (1), should be caused by low eff.

  5. (1). MuTr#1. PC2 Res(R)=10cm, Res(phi)=1o. Mutr#1 tile size 25cm/PC2 tile size 60cm Effect of PC2 position Resolution (2). MuTr#1. PC2 Res(R)=20cm, Res(phi)=1o. Mutr#1 tile size 25cm/PC2 tile size 60cm • PISA hits is smeared in R/. Need to re-do using real detector configuration. • efficiency for MuTr/PC2/symset LUT is only 76%. Need to understand. • efficiency for angle cut <1 degree is less since the PC2 angular resolution is 1 degree. • Efficiency for LUT start to drop after PC2 resolution > 10cm.

More Related