1 / 16

Gel Filtration in Insulin Preparation

Gel Filtration in Insulin Preparation. Presented to: CHEE 450 April 1 st , 2009 Samina Dhalla, Robert Macnamara and Terri Semler. Presentation Overview. Background Design Conclusion Questions. Background. Background.

felix
Download Presentation

Gel Filtration in Insulin Preparation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Gel Filtration in Insulin Preparation Presented to: CHEE 450 April 1st, 2009 Samina Dhalla, Robert Macnamara and Terri Semler

  2. PresentationOverview • Background • Design • Conclusion • Questions

  3. Background

  4. Background • Gel filtration is used in this biological process to separate insulin from unwanted components • Gel filtration is used to separate molecules based on size • Two methods of separation: • Group separations • High-resolution fractionation http://www.siumed.edu/~bbartholomew/images/chapter6/F06-09.jpg

  5. Design

  6. Loading Sample

  7. Gel Media • Consists of porous matrices composed of spherical particles • Size • Packing density • Porosity • Chemical and physical stability • Factors to be considered: • Resolution desired • Molecular weights of the target proteins and contaminants to be separated • Rate and scale of filtration http://www5.gelifesciences.com/aptrix/upp00919.nsf/4a0f132842ea4d354a25685d0011fa04/50c849d0d5b16ba0c1256e92003e865b/$FILE/GE_Gel%20Filtration.swf

  8. Types of Gels • Bio-Gel P-4 was chosen

  9. Column Dimensions • Design Considerations: • Maximum height for column is 100cm before gel will be crushed • Sample volume injected should be 25% of the column volume • Specifications From SuperPro • Approach Velocity of 300 cm/hr • Total feed of 14,110 L in 20 cycles through filter

  10. Recommended Column Parameters are based on a total volume per batch of 14,110 L with 20 loads per batch being processed through the column

  11. Conclusion

  12. Conclusion • Decided on Bio-Gel P-4 manufactured by Bio-Rad • Using three columns stacked consecutively on one another manufactured by GE Health • Total elution time of 4.23 hours

  13. references

  14. References Amersham Biosciences. “Gel Filtration – Principles and Methods”, Sweden (2002), pp 1-120. Belter, P., Cussler, E., and Hu, W. “Elution Chromatography” in “Bioseparations – Downstream Processing for Biotechnology”, United States (1988), pp 181 – 188. Bio-Rad Laboratories. “Bio-Gel P Polyacrylamide Gel, Instruction Manual”, California, U.S. (2000), pp 1 -14. Sigma-Aldrich (2009). Retrieved on March 23, 2009 from: http://www.sigmaaldrich.com/canada-english.html

  15. Questions ?

More Related