An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EASY bus 48 V - power IN OUT OUT 48 V - service EASY Crate A3486 AC/DC has 2 channels of 2 KW each * 3 boards with safety factor 2 ** 6 boards with safety factor 2 Dr. Pierluigi Paolucci - INFN di Napoli

  2. EASY crate back schema Dr. Pierluigi Paolucci - INFN di Napoli

  3. EASY bus 48 V - power IN OUT OUT 48 V - service EASY crate connection schema Dr. Pierluigi Paolucci - INFN di Napoli

  4. S1H02-06 EASY 1 2 3 456 - EASY 1 2 3 45 6 - turbine 4U fan tary fan tary heat exchange heat exchange 8U 36 input ch. 24 ch. 36 ch. sect 05-06 HV distributor sect 11-12 HV distributor sect 03-04 HV distributor sect 09-10 HV distributor sect 01-02 HV distributor sect 08-07 HV distributor 12 ch. 24 ch. 44 U 36 input ch. 8U 48 output ch. 48 output ch. EASY 1 2 3 4 - - - 24 input ch. 8U fan tary heat exchange spare HV distributor 2U air deflector NEW USC55 barrel HV system "wheel" crate schema • General Information • max HV EASY board: 7 ch. • max EASY crate: 42 ch. • HV distributor: • 32 input ch (2 sectors) • 16 output ch. • Rack height tot: 56 U • turbine 4 U • air defl. 2 U • Rack available height 50 U Total: 72/96 ch. • We need (per wheel/rack) • 72 ch  12 HV boards (reduced*) • 96 ch  16 HV boards (final) • 3 EASY crate (4-4-4) (6-6-4) • 3 FAN crates + heat exchange • 6 distributors + 1 RB4-sect4 join • * RB3 and RB4 joint together (12 + 12) Dr. Pierluigi Paolucci - INFN di Napoli

  5. AC/DC 48V power AC/DC 48V service AC/DC 48V power AC/DC 48V power 3U 3U 3U 3U 2x2 KW (spare ?) 2x2 KW 2x2 KW 2x2 KW NEW USC55 HV barrel racks composition • HW numbers • 15 EASY crates • 60-80 HV boards A3512 • 360-480 HV channel • 30+4 HV distributors • 2 SY1527 mainframes • 3 or 4 AC/DC 48 V - A3486 (or A3485) 136 components S1H07 turbine 4U SY1527 HV 8U SY1527 LV 8U 800 cables • CABLE numbers • EASY power (direct) 5 • EASY power (daisy) 10 • EASY service (direct) 2 • EASY service (daisy) 14 • Branch Contr. (direct) 2 • Branch Contr. (daisy) 14 • Fan unit contr. 15 • EASY Ground - 15 • SY1527 ground - 2 • 480 HV input + 240 HV out 34U 2U air deflector Dr. Pierluigi Paolucci - INFN di Napoli

  6. HV production * 10 have been already financed (not yet ordered) = 35 KEuro Dr. Pierluigi Paolucci - INFN di Napoli

  7. LV production Dr. Pierluigi Paolucci - INFN di Napoli