Review SAR, Chapter 15 – Loss of Feed Water flow (LOFW)

Review SAR, Chapter 15 – Loss of Feed Water flow (LOFW). VARANS . Tung Duong. Categorization of PIE. The considered initiating event presents the design condition of category 2 and refers to the group of initiating events resulting in reduction in heat removal from the primary circuit. .

fadey
Download Presentation

Review SAR, Chapter 15 – Loss of Feed Water flow (LOFW)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Review SAR, Chapter 15 – Loss of Feed Water flow (LOFW) VARANS Tung Duong

  2. Categorization of PIE • The considered initiating event presents the design condition of category 2 and refers to the group of initiating events resulting in reduction in heat removal from the primary circuit.

  3. Acceptance criteria • Pressure in the reactor coolant system and SG steam lines will be less than 115 % of the design value. • The minimum DNBR shall be not less than the assigned value for the assumed correlation with a confidence probability of 95%. The applied DNBR correlations shall be based on experimental results that correspond to the conditions of core cooling and to the given design of fuel. • Fuel pellets do not melt even locally (temperature is less than 2540оС for “burnt-up” fuel and less than 2840оС for “fresh” fuel). • Radially-averaged fuel enthalpy shall not exceed 586 J/g UO2 in any fuel pellet. • Acceptance criteria are fully listed. • Need to show information about CHF correlation used and the DNBR limit should be given by value with considering uncertainty

  4. BICs • Main parameters, delay times, and set points are presented in section 15.4. • All feed-water pumps supply into SG are tripped. • Need section 15.4

  5. BICs

  6. Availability of components and systems Conservative are selected for each acceptance criterion

  7. Computer codes and calculation procedure The LOFW calculation is made with the use of computer code DINAMIKA-97 included into the computer code package TRAP-97 described in section 15.3. The code package TRAP-97 is validated against large scope of domestic and international experimental data and certified by Russian regulatory body.  Acceptable

  8. Results Initial power is not 110% nominal power

  9. Results Minimum DNBR about 1,07 but information about CHF correlation is not included  not confirmed

  10. Results Below 110% nominal power

  11. Results Inconsistence of figure 5 and 6

  12. Thanks for your attention