1 / 29

Superconducting Generators for Wind Turbines

Superconducting Generators for Wind Turbines. Advisor & Client Dr. James McCalley. Abrahem Al- afandi Hamad Almutawa Majed Ataishi. Overview. Project Background. - What is it? Why? Objectives. Approach Taken. Suggested Designs. Design Evaluation Methods . Project Background .

emile
Download Presentation

Superconducting Generators for Wind Turbines

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Superconducting Generators for Wind Turbines Advisor & Client Dr. James McCalley Abrahem Al-afandi Hamad Almutawa MajedAtaishi

  2. Overview • Project Background. - What is it? • Why? • Objectives. • Approach Taken. • Suggested Designs. • Design Evaluation Methods.

  3. Project Background • What is it? • Inland Direct-Drive Wind Turbines. • 5-MW PMSG. • 10-MW HTS. • Why Direct-Drive? • Integrated in nature. • Avoiding the need for large, maintenance-intensive gearbox. • Reduced size and weight. • Efficient & Reliable. RPM RPM

  4. Objectives • Suggested 5MW turbine using permanent magnet generator. • Suggested 10 MW turbine using high temperature Superconductor generator. • Each suggested design has: • To be Cost-effective. • High Energy yield. • Low weight and volume. • Suitable cooling system.

  5. Our Approach • Top to bottom view of steps taken : components & operation of Generator Direct-Drive vs. Conventional Feasible for 10-MW Feasible for 5-MW PMSG HTS Materials Different Topologies Materials Different Topologies Suggested Design 2 Suggested Design 1 Performance Attributes Performance Attributes Cost Analysis Cost Analysis Designs Evaluation

  6. The Difference PMSG HTS Schematic layouts HTS is lighter for higher MW Cooling Systems

  7. Before Choosing Promising Designs • There needs to be a balance among electrical, magnetic, thermal, mechanical, and economic factors for a well designed generator. • These factors are always conflicting with each other. • No matter what kind of methods designers use to optimize, the keys are: • Low cost. • High reliability and availability. • High cost always prevents generators from commercialization. In General, the better topology of DD generators has the maximum output, minimum expenses and highest reliability.

  8. 1. PMSG Topologies • Air Gap Orientation. • Radial has relatively small diameter. • Axial ha a compact design. • Stator Core Orientation. 3.Longitudinal is used in conventional designs. 4. Transversal has less copper losses, diffi. To con. • PM Orientation with respect to air-gap. 5. Surface-Mounted PM is easer to construct. 6. Flux- concentrating PM has higher remnant flux. VS. 2. 1. 3. VS. 4. VS. 6. 5.

  9. 1. PMSG Topologies Cont. • Copper Housing. 7. Slotted has a better retention of the armature windings, but has cogging torque. 8. Slot-less has low cogging torque. • Iron Core VS. Coreless 9. Iron-Core has lamination losses and more weight. 10. Coreless eliminates cogging torque and reduce weight. 8. 7. VS. 9. 10. VS.

  10. Two Possible PMSG Designs Axial-Longitudinal-Surface Mounted- Coreless- Slot-less Design 1 Design 2 Radial-Longitudinal-Surface Mounted-Iron core-Slotted • Axial machines are not suited for MW power ratings, since the outer radius becomes larger, and the mechanical dynamic balance must be taken into consideration.

  11. PMSG Materials • Three PM materials were investigated. Good Material to be used

  12. 2. HTS Topologies • Partially VS. fully superconductor. • Axial VS. Radial flux. • Air-core VS. Iron-core

  13. Fully VS. Partially Fully Partially Partially is dominant until a breakthrough in AC losses is made

  14. Axial VS. Radial Axial Radial Suitable for MW class

  15. Air-core VS. Iron-core Air-core Iron core Promising if HTS price goes down Better performance

  16. HTS Material

  17. Recommended Design 1 • 5-MW PMSG wind Generator: Radial Inner-rotor Outer-rotor

  18. Recommended Design 2 • 10 MW SCDD Wind Generator: • Partially SC with HTS field winding on the rotor. • Stationary armature windings. • Radial flux machine. • Iron-cored rotor with iron teeth stator winding. From AMSC

  19. Performance Attributes A good design should not only have high torque density, but it has to have a low cost/torque ratio. Comparison table This picture shows that RFPM has the lowest cost/torque ratio. (good) This picture shows that RFPM has a relatively low Torque density.

  20. Cost Analysis Model • Existing model From the National renewable energy lab. • The purpose of the model is to calculate ICC, AOE. • The Model is valid for: 1-Power range from 0.75MW - 5MW. 2-Rotor diameter: 80m-120m. • It is valid for extrapolation for power output up to 10MW and rotor diameter of 200m.

  21. Variables For cost evaluation we need to get: • AEP(Annual Energy production). • ICC(initial capital cost). • AOE(Annual operating expenses). • FCR(Fixed charge rate). • COE(Cost of Energy).

  22. AEP • AEP = CF(capacity factor) * rated power * 8760 hours • The capacity factor varies depending on the wind farm. • AEP for 5MW generator is = 13.14GWh. • AEP for 10MW generator is = 26.28GWh. • The uncertainty percentage is: • +/-0.02 for 5MW generator. • +/- 0.05 for 10MW generator.

  23. Calculated Results

  24. Design evaluation Methods We were given 4 ways to evaluate our designs: 1- Evaluation using proper software. ✖ 2- Hardware evaluation. ✖ 3- Literature review. ✔ - Technical papers. - IEEE articles and researches. 4- Industry experts. ✔ - AMSC(HTS). - ABB & Gamesa(PMSG).

  25. Cost Analysis Evaluation Validating AEP:

  26. COE in $/KWh for different power ratings and diameters:

  27. Cost Estimation

  28. Remarks • Wind turbines are growing in power capacity with each new generation. • Wind farm economics is demanding increased reliability to minimize cost and maximize productivity. • More power per tower.

  29. Question?

More Related