1 / 1

The impact of the use of new X-Ray technology to ensure the best placement of catheters

The impact of the use of new X-Ray technology to ensure the best placement of catheters LUZ,C.C.; SANTOS,J.L.S.;LASELVA,C.R.;SILVA,V.C Albert Einstein Hospital. Abstract. Methods. Results.

dyllis
Download Presentation

The impact of the use of new X-Ray technology to ensure the best placement of catheters

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The impact of the use of new X-Ray technology to ensure the best placement of catheters LUZ,C.C.; SANTOS,J.L.S.;LASELVA,C.R.;SILVA,V.C Albert Einstein Hospital Abstract Methods Results Comparative retrospective study between the period of January and February 2013 and January and February 2014, on the use of conventional XR versus XR portable XRD-CarestreamDRX-1 system, for placement of peripherally inserted central catheter (PICC). 324 insertions were evaluated in 2013, and 332 insertions in 2014. Data were collected in a hospital considered large, with approximately 800 beds, tertiary care, in Sao Paulo, Brasil. The best results in relation to the maintenance and improvement of helpful life of the catheters, are related to the initial placement of the same. In Brazil, we do not have technology already sold in the market to ensure the placement of catheters, as Sherlock and Vasonova TPS. In our service we have available mobile RX (XRD), portable, allowing us the end of the procedure, observe the image of the positioning of the catheter at the bedside, thus ensuring proper positioning of the catheter to the patient's safety and procedure . With this, we are reducing the complications that comes from improper positioning, particularly thrombosis. We managed to reduce the time from assessment until release of the catheter in 1 hour. (There was 2 hours and now is 1 hour). Catheter´s bad position rates improved. There was an increase in the success rate of PICC placement in the Superior Vena Cava 82.20% (January and February 2013) to 90.10% (January-February 2014) average, which represents an increase of 7.90 % in this rate. Objective • To evaluate the position of the PICC line, immediately after insertion. • To solve the malposition immediately after detection. • To reduce the total procedure time. • To esure that medications are administered immediately after the procedure. • To reduce rates of adverse events and poor positioning. • To reduce loss of materials for dressings duplicate. References Conclusions -PittirutiM, The intracavitary ECG method for positioningthetipof central venouscatheters: resultsofanItalianmulticenterstudy. J Vasc Access. 2012 Jul-Sep;13(3):357-65. -Katheria AC, A randomizedcontrolledtrialofultrasound-guidedperipherallyinserted central catheterscomparedwith standard radiograph in neonates. J Perinatol. 2013 Oct;33(10):791-4. -Roberto P. Central venouslineplacementisnotcompromisedbythechoicebetweendifferentinsertion sites. Studyperformed in cardiovascular surgerypatient. RevPortCirCardiotoracVasc. 2013 Jan-Mar;20(1):13-7 The use of new technology for radiological confirmation - DRX has a positive impact on the success rate of PICC line placement, improving Catheter´s bad position rates.

More Related