1 / 7

A further use of VID-learning March 2011

A further use of VID-learning March 2011. Bob Sultan (bsultan@huawei.com). VDP-Learning (currently in Draft). Benefit: A unicast frame received by an EVB Bridge will not be flooded if the frame is destined for a <MAC, VID> ‘registered’ by the adjacent EVB Station. Assoc <A, m>. Assoc <A, m>.

demont
Download Presentation

A further use of VID-learning March 2011

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. A further use of VID-learningMarch 2011 Bob Sultan (bsultan@huawei.com)

  2. VDP-Learning (currently in Draft) • Benefit: A unicast frame received by an EVB Bridge will not be flooded if the frame is destined for a <MAC, VID> ‘registered’ by the adjacent EVB Station.

  3. Assoc <A, m> Assoc <A, m> Data <A, m> Data <A, m> Data <A, m> Data <A, m> Data <A, m> Data <A, m> Without VDP Learning Bridge 4 Bridge 5 EVB Station 1 EVB Station 2 EVB Bridge 3 With VDP Learning Bridge 4 Bridge 5 EVB Station 1 EVB Station 2 EVB Bridge 3

  4. A modest benefit • Flooding avoided at an EVB Bridge only for frames destined to <A, m> associated with an adjacent EVB Station; • In general, if the data center contains 100 EVB Bridges, the saving will represent a 1% improvement in flooding;

  5. Assoc <B, n> Assoc <A, m> LLDP EVB TLV NOF = TRUE Data <C, p> Data <C, p> Data <A, m> Data <A, m> Data <C, p> NO FLOOD ZONE A larger benefit is possible Bridge 4 Bridge 5 EVB Station 1 EVB Station 2 EVB Bridge 3 I promise that I will ‘register’ (via VDP Associate) all <MAC, VID> pairs associated with this URP. No flooding when <A, m> has been registered is business as usual for VDP-learning Some <C, p> that is not associated with an EVB Station attached to Bridge 3 <C, p> is unknown, so it is flooded but not flooded on the ‘No Flood’ port to EVB Station 2 as <C, p> cannot be there

  6. The ‘No Flood’ Option • If the EVB Station commits to always register <MAC, VID> pairs on the URP; • then the EVB Bridge will never flood unknown unicast on the corresponding SBP; • if the <MAC, VID> is not found in the FDB of the EVB Bridge, then it cannot lie on the attached EVB Station as it would have been registered;

  7. Update to Draft • Identify NOF bit in existing capabilities field of the EVB TLV; • This is in addition to the existing bit that indicates whether VDP-learning is supported; • [The VDP-learning bit is described in the text, but it appears to be omitted from the figure; should fix;] • FDB contains entry for ‘no more specific MAC or VID’ in which case port map is set to forward on all ports; • when EVB Bridge is informed by EVB TLV that SBP is set to NOF, it sets the corresponding entry of the port-map to ‘filter’; • I can provide text and figures to add to current draft (a small change) if consensus;

More Related