Focal Plane Scanner

Focal Plane Scanner. Jeff Martin University of Winnipeg with: Jie Pan, Peiqing Wang, David Harrison. Motivation. Q 2 determination, background studies, all done at 10 nA using tracking system. Region III operable up to 100 nA. Qweak production running 180 A.

cleta
Download Presentation

Focal Plane Scanner

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Focal Plane Scanner Jeff Martin University of Winnipeg with: Jie Pan, Peiqing Wang, David Harrison

  2. Motivation • Q2 determination, background studies, all done at 10 nA using tracking system. • Region III operable up to 100 nA. • Qweak production running 180 A. • Need a way to extrapolate over 3 orders of magnitude.

  3. Qweak Focal Plane Scanner • A scanning detector with small active area to sense high-energy electrons, operable at any beam current. • Similar technique used in E158 and HAPPEx. • For E158, it was used to determine optics parameters, confirm Monte Carlo predictions of rates.

  4. Scanner Principle pre-rad quartz radiator Design criteria: • 1 cm2 active area. • 1 MHz max rate allows operation in counting mode with two PMT’s. • operable at both high and low current. Č scattered electrons air-core light pipe PMT

  5. Scanner Concept scattered electrons beam view side view

  6. Implementation in Qweak Č-bar y-axis motion x-axis motion • 2D motion assy scans behind Č-bar • Mount in any one octant at a time • Attach to fixed support structure • Motion assy mounted “inside” Č-bars

  7. Recent Progress on Scanner • 3/06 – Approval from CFI received (detector lab) • 4/06 – Funding from NSERC received (scanner) • Report for today: • Start of prototyping tests related to detector performance. • Simulation of detector performance. • Mechanical design • Mounting and 2D motion assy. • Detector assy.

  8. Prototyping Tests (Pan, Wang, Harrison) • 2” tube lined with “Alzak” sheet (aluminum sheet with PVD aluminum on top, and clear anodized) “Anomet” “MIRO 2”

  9. Prototyping Tests – Cosmics Testing upper trigger test detector lower trigger inside Alzak tube is a small test scint mounted on a plunger

  10. Prototyping Tests • MCA reads out shaped pulse height. • Begun work with small scintillator samples. (Plan to transition to quartz) • Begun work with high reflectivity light pipes. • Electronics to be replaced with CFI funded detector lab.

  11. Simulation • Builds on QweakSim (K. Grimm, M. Gericke) • Currently at stage of benchmarking vs. E158 NIM article.

  12. Simulation – comparisons to E158 NIM Jie Pan E158 • work in progress • q.e. model not right, etc. different prerad

  13. Mechanics • support structure (P. Medeiros, G. Smith) • 2D motion assy. • detector assy. (P. Wang and G. Mollard @ UM)

  14. Mechanics • support structure • early 2006, decision to not use R3 rotator • plan now is to mount to fixed Cherenkov-bar support structure, most of device in towards beamline. • motion octant-to-octant possible by bolting device in place • need drawings! • 2D motion assy. • budgetary quote from Bosch-Rexroth. • no progress other than some discussions with P. Decowski (E158 scanner) on rad hardness.

  15. Mechanics • detector assy. • initial 2D CAD drawings • begun 3D SolidWorks model (P. Wang) • eventually, support from UM shop (G. Mollard) starting on SolidWorks design

  16. Summary and to-do list • Answer prototyping/simulation questions: • radiator design (quartz? scint? size? tilt angle? prerad?) • tube diameter (backgrounds) • two-tube layout (backgrounds and fiducial area) • establish viability of coincidence technique (rates) • Mechanics • support structure – need P. Medeiros’ time. • purchase 2D motion assy. and program it. • design and build a mechanical mock-up of detector assy and then a realistic detector

  17. Additional Usesof a Scanner Detector • Scan over large fiducial region, into inelastic region, over Cherenkov bar light guides, to get additional confidence in backgrounds. • “Light map” can be compared to simulation. • Q2 extrapolation/determination • mini-torus setting during production running? • gas vs. liquid target extrapolation? • at least, complementary to region III.

  18. Implementation in Qweak Č-bar y-axis motion x-axis motion • 2D motion assy scans behind the Č-bar • Mount in one octant, attach to fixed support structure

  19. Implementation in Qweak

  20. Implementation in Qweak

  21. Implementation in Qweak

  22. Implementation in Qweak

  23. Expected rates at 180 A courtesy J. Mammei • Max rate = 1 MHz

  24. Procedure • Measure light distribution with scanner at low beam current acceptable to region III and Cherenkov bar coincidence. • Measure light distribution with scanner at 180 uA. • If they are the same, region III/Cherenkov light distribution believable at 180 uA to high confidence. • Note: scanner light map will not be the same as the region III/Cherenkov bar coincidence map.