1 / 3

How to use wet scrubbing processes for gaseous control?

<br>The best and advanced way to keep gas production and air pollution under proper control is through the various types of wet scrubbing procedures and options.<br><br>Source url: https://clear-ion.com/blog/how-to-use-wet-scrubbing-processes-for-gaseous-control/

clearion
Download Presentation

How to use wet scrubbing processes for gaseous control?

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. How to use wet scrubbing processes for gaseous control? By using a liquid, Wet Scrubber helps to remove pollutants from an exhaust stream. In the gaseous emission control applications, these scrubbers eliminate pollutants by absorption. Exactly, for this reason, wet scrubbers are designed specifically for gaseous pollutant control which is referred to as absorbers. Yes, absorption is very efficient while monitoring the pollutant gases which are available in the concentration, but also is reasonable for the gases at the dilute concentrations once the gas is soluble in the absorbent. The dynamic absorption force is associated with the soluble gas amount in the solute gas concentration and has streamed in the liquid film in the interaction with the gas. Wet scrubbers depend on the large surface area creation of scrubbing liquid which lets the intimate interaction between the gas and liquid. The large surface area creation can be skillful bypassing the liquid on a various variety of media or just by creating a spray of droplets. There are various wet scrubber designs, that include tray-type, spray tower, as well as packed-bed wet scrubbers and they are commonly referred to as low- energy scrubbers. Performance Indicators Various Parameters can be utilized as indicators of the performance of wet scrubbers. The most suitable indicators to control based on different factors that includes pollutant type, exhaust gas characteristics, and scrubber design. Pressure differential, scrubber liquid, and liquid flow rate outlet concentration are the main indicator of performance. Liquid Flow Rate

  2. Gas flow rate basically a frequent based process conditions and it is the major design that considers the scrubber. The liquid-to-gas ratio is decided and maintained by the scrubber liquid flow rate. Scrubber liquid flow rate is the main performance indicator provided the liquid is being distributed properly, and the liquid-gas interface is properly maintained. Higher liquid flow rates are actually indicative under these conditions for the higher control levels. Although for packed-bed scrubbers, there is a serious flow rate upon which flooding happens. Gas Flow Rate Exhaust gas flow rate actually put a bad impact on the L/G ratio that is a key design parameter for the wet scrubber. Gas flow is commonly a frequent parameter and might be controlled to make sure that the flow is within the design range. An enhancement in the exhaust gas flow rate, without a corresponding, enhance in the liquid flow rate, might result in a lessening in re L/G ratio that commonly results in the scrubber control’s decreased efficiency. Fan motor current also can be controlled as a replacement for exhaust gas flow rate. Scrubber Liquid Outlet Concentration The scrubber liquid outlet concentration is a tough indicator of gaseous pollutant removal competence. The increased concentration of pollutants might result in lower removal efficiency of the pollutant as of enhanced vapors pressure of the component in the liquid and lowering of the absorption. For wet scrubbers used to control acid gas emissions, monitoring scrubber liquid pH is an adequate surrogate for scrubber liquid outlet concentration. Pressure Differential It is one of the most critical indicators of the performance of the wettest scrubber designs. Pressure Differential remains constant as well reflects the normal operation of the gas flow and liquid flow through the system. For packed-bed scrubbers, bed plugging can result in increased pressure differential, the increase in pressure in pressure differential can resemble performance decrease. Scrubber Liquid pH Scrubber liquid pH is acid gas indicator removal efficiency. A drop in the pH can actually notify that the inlet concentration of gas is enhancing or that decreased acid is being neutralized. If caustic as other acid counteracting chemicals are used, and a modification in pH can notify a problem with the chemical system. Outlet Gas Scrubber Temperature

  3. For wet scrubbers used to monitor the thermal procedures, the scrubber consumes gas temperature is also a performance indicator. Enhances in the exhaust or outlet have stream temperature are the operation modification indication. Either the procedure exhaust temperature has enhanced, or the flow rate gas has increased, or the liquid flow rate has decreased. Parameters to control as an alternative to the liquid scrubber outlet concentration consists of scrubber liquid pH, scrubber liquid gravity, and scrubber blowdown rates. For those systems which monitor gaseous stream with less particulate matter loadings, there is no advantage to controlling the scrubbing liquid solids content. Clear Ion has the best deal for Wet Scrubber in India and you can get it in different technical specifications at a very reasonable rate. Source Url: https://clear-ion.com/blog/how-to-use-wet-scrubbing-processes-for-gaseous-control/

More Related