1 / 18

Emanuele Pace XUVLab – Dept. Astronomy & Space Science University of Florence - Italy

EUSO in flight calibration. Emanuele Pace XUVLab – Dept. Astronomy & Space Science University of Florence - Italy. EUSO calibration. Lab calibration Sub-systems, pre-flight, vibrations, thermo-vacuum In orbit calibration. Two different objectives and approaches:

asis
Download Presentation

Emanuele Pace XUVLab – Dept. Astronomy & Space Science University of Florence - Italy

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EUSO in flight calibration Emanuele Pace XUVLab – Dept. Astronomy & Space Science University of Florence - Italy EUSO General Meeting - Huntsville (USA), 20 May 2003

  2. EUSO calibration • Lab calibration Sub-systems, pre-flight, vibrations, thermo-vacuum • In orbit calibration • Two different objectives and approaches: • Track simulation and atmosphere sounding • Ground- or airplane-based light sources • Calibration of the telescope performance • Spectroradiometry on board EUSO General Meeting - Huntsville (USA), 20 May 2003

  3. In Palermo EUSO General Meeting - Huntsville (USA), 20 May 2003

  4. Instrument calibration • The telescope or optical system • The focal plane detector • The front-end and trigger electronics Ground based calibration The collected signal for a given incident flux F is: Calibration required! EUSO General Meeting - Huntsville (USA), 20 May 2003

  5. Requirements • Spectroradiometry in the range 300-400 nm • Photon counting regime: Integration time: 200 ns Time resolution: 20 ns Background: < 5 x 104 ph/s/px (<10-2 ph/px) • Uncertainty <10% • Very low impact on the mass budget • Low power consumption • No movable components • Monitor for the light source EUSO General Meeting - Huntsville (USA), 20 May 2003

  6. 125 cm FL1 FL2 FS Ray tracing Input: Transmittance of the Teflon diffuser Total transmittance of lenses 70% Integration time = 200 ns No scattered light Ø FS= 2.5 m Flux on FS = 8 x 109 ph/s = 1600 ph on FS = 0.3 ph / MAPMT = ~10-2 ph / px EUSO General Meeting - Huntsville (USA), 20 May 2003

  7. Ray tracing Lambertian source (106 rays simulation) Wavelength =357 nm Number of pixels7800 EUSO General Meeting - Huntsville (USA), 20 May 2003

  8. Source arrangement EUSO General Meeting - Huntsville (USA), 20 May 2003

  9. LED • GaN, InGaN, AlGaN UV LEDs • Emission wavelengths @ 350 nm, 370 nm, and 393 nm • Photon flux: 1015 ph/s in a narrow beam (15°) • Power consumption: ~ 120 mW • Very lightweight: < 10 g • Commercially available by many companies, such as Nichia Corp., Marubeni Sunnyvale Corp., Nitride Semiconductor Co., Roithner Lasertechnik. EUSO General Meeting - Huntsville (USA), 20 May 2003

  10. Electronics box 30 mm 50 mm Multiple-LED source Si LED’s and photodiode are radiation soft Rad-hard BOX : 4 mm Al EUSO General Meeting - Huntsville (USA), 20 May 2003

  11. Detectors on the Focal surface R1635P head-on PMT from Hamamatsu Corp. PRO • Monitoring the optical performance of the lenses CON • Photomultipliers as unique choise • Long-term detector calibration not available • Impact on mass and power budget EUSO General Meeting - Huntsville (USA), 20 May 2003

  12. Calibration System Obscuration on 2nd Fresnel lens Øobs= 200 mm EUSO General Meeting - Huntsville (USA), 20 May 2003

  13. Arrangements Sketch are not in scale EUSO General Meeting - Huntsville (USA), 20 May 2003

  14. Mass & Power No contingency EUSO General Meeting - Huntsville (USA), 20 May 2003

  15. Next step I suggest and solicitate the discussion on calibrations in view of a Calibration Working Group to coordinate and develop activities on this crucial subject Items Sub-systems vibration tests thermo-vacuum tests pre-flight on orbit ground-based Contributions from WG’s on • Optics • Instrument structure • Simulations • LIDAR • Focal surface detector • Trigger and readout electronics EUSO General Meeting - Huntsville (USA), 20 May 2003

  16. EUSO General Meeting - Huntsville (USA), 20 May 2003

  17. Targets • Transmissivity and uniformity changes of the two Fresnel lenses • Solarization and wavelength bandpass shift of the UV filters • Transmissivity or reflectivity reduction of optical adapter • Variation of the efficiency of the optical adapters+detector system due to vibrations, possible damage, misalignments, increased scattering power, etc. • Variations of the detector gain and photocathode QE • Failure of some photo-detectors • Increase of the scattered light level EUSO General Meeting - Huntsville (USA), 20 May 2003

  18. Transmittance of Teflon EUSO General Meeting - Huntsville (USA), 20 May 2003

More Related