TAMÁS JÁNOS SZABÓ DLA – SENIOR ARCHITECT, FINTA &PARTNERS ARCHITECTURAL STUDIO Ltd.

K&H HEADQUARTERS - BUDAPEST ACHIEVING LEED GOLD – DESIGN TEAM PERSPECTIVE ON CREDITS, CRITERIA AND DOCUMANTATION. TAMÁS JÁNOS SZABÓ DLA – SENIOR ARCHITECT, FINTA &PARTNERS ARCHITECTURAL STUDIO Ltd. K&H HEADQUARTERS. K&H HEADQUARTERS. K&H HEADQUARTERS. K&H HEADQUARTERS. K&H HEADQUARTERS.

ash
Download Presentation

TAMÁS JÁNOS SZABÓ DLA – SENIOR ARCHITECT, FINTA &PARTNERS ARCHITECTURAL STUDIO Ltd.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. K&H HEADQUARTERS - BUDAPEST ACHIEVING LEED GOLD – DESIGN TEAM PERSPECTIVE ON CREDITS, CRITERIA AND DOCUMANTATION TAMÁS JÁNOS SZABÓ DLA – SENIOR ARCHITECT, FINTA &PARTNERS ARCHITECTURAL STUDIO Ltd.

  2. K&H HEADQUARTERS

  3. K&H HEADQUARTERS

  4. K&H HEADQUARTERS

  5. K&H HEADQUARTERS

  6. K&H HEADQUARTERS

  7. K&H HEADQUARTERS

  8. K&H HEADQUARTERS

  9. K&H HEADQUARTERS

  10. K&H HEADQUARTERS

  11. SYSTEM STRUCTURE CREDITS K&H HEADQUARTERS

  12. THE LEED SYSTEM – TYPICAL FEATURES • LEED PRODUCT PORTFOLIO: • New construction • Existing buildings • Commercial interiors • Core & shell • Leed for homes • Neighborhood development K&H BANKSZÉKHÁZ ISMERTETÉSE K&H BANKSZÉKHÁZ ISMERTETÉSE

  13. THE LEED SYSTEM – TYPICAL FEATURES • 2. RATING SYSTEM: • Based on mandatory prerequisites (no points) and available credits • Certified 26-32 points • Silver 33-38 points • Gold 39-51 points • Platinum 52-69 points K&H BANKSZÉKHÁZ ISMERTETÉSE K&H BANKSZÉKHÁZ ISMERTETÉSE

  14. THE LEED SYSTEM – TYPICAL FEATURES • 3. DOCUMENTATION • Online • Language of documentation: English • Units: United States customary units • Standards & regulations: e.g. ASHRAE • Certifications (manufacturers): e.g. FSC, SRI K&H BANKSZÉKHÁZ ISMERTETÉSE K&H BANKSZÉKHÁZ ISMERTETÉSE

  15. STRUCTURE K&H HEADQUARTERS

  16. LEED STRUCTURE – K&H BANK LEED ADMINISTRATOR INDEPENDENT MECHANICAL ENGINEER ENERGY SIMULATION HIRED BY THE INVESTOR DRAFT SET UP OF CREDITS PROJECT CONTROL HVAC ENGINEER ARCHITECT INVESTOR ELECTRICAL ENGINEER LANDSCAPE ARCHITECT BUILDING CONTRACTORS K&H HEADQUARTERS

  17. CREDITS K&H HEADQUARTERS

  18. GROUPS OF LEED CREDITS SUSTAINABLE SITES SS MATERIALS & RESOURCES MR WATER EFFICIENCY WE INDOOR ENVIROMENTAL QUALITY EQ ENERGY & ATHMOSPHERE EA INNOVATION IN DESIGN ID K&H BANKSZÉKHÁZ ISMERTETÉSE K&H HEADQUARTERS

  19. SUSTAINABLE SITES • SUSTAINABLE SITES • Aim: to decrease buildings impact on ecosystem • Responsible: • Investor • Architect • Landscape architect • Electrical engineer • 3. Submittal documentations: • Confirmations • Calculations K&H BANKSZÉKHÁZ ISMERTETÉSE K&H HEADQUARTERS

  20. SUSTAINABLE SITES • SUSTAINABLE SITES • SS c1 Prerequisite: Avoid development of improper sites Confirmation • SS c2 Development density & Community Connectivity Calculation • SS c3 Brownfield redevelopment Confirmation • SS c4 Alternative transportation • Public transportation access (1/2 mile – rail, subway OR ¼ mile at least two stops for bus lines) Confirmation • Bicycle storage & changing rooms (racks for at least 5% of building users, shower and changingfacilities within 200 yards for 0,5 % of occupants) • Calculation • Low-emission & fuel-efficient vehicles (preferred parking for 3% of occupants) Calculation • Parking capacity (not exceed minimum local zoning requirements and parking for carpools for 5% of total provided parking spaces)Confirmations • d K&H BANKSZÉKHÁZ ISMERTETÉSE K&H HEADQUARTERS

  21. SUSTAINABLE SITES • SUSTAINABLE SITES • SS c1 Prerequisite: Avoid development of improper sites Confirmation • SS c2 Development density & Community Connectivity Calculation • SS c3 Brownfield redevelopment Confirmation • SS c4 Alternative transportation • SSc5 Site development (maximize open space – reduced footprint, vegetated open space must exceed the local requirements with 25%)Calc. & Confirm. • SS c6 Storm water design (avoid erosion and water pollution)Calculation • SSc7 Heat island effect (green roof, Solar Reflectance Index)Calculation • Light pollution reduction (minimize light trespass, reduce sky glow)Calc. & Confirm. K&H BANKSZÉKHÁZ ISMERTETÉSE K&H HEADQUARTERS

  22. EXAMPLE: Development density & Community Connectivity K&H BANKSZÉKHÁZ ISMERTETÉSE K&H BANKSZÉKHÁZ ISMERTETÉSE

  23. EXAMPLE: Bicycle storage & changing rooms K&H BANKSZÉKHÁZ ISMERTETÉSE K&H BANKSZÉKHÁZ ISMERTETÉSE

  24. WATER EFFICIENCY • WATER EFFICIENCY • Aim: reduction of consumption of potable water • Responsible: • HVAC engineer • Landscape architect • Submittal documentations: • Calculations K&H BANKSZÉKHÁZ ISMERTETÉSE K&H HEADQUARTERS

  25. WATER EFFICIENCY • WATER EFFICIENCY • WE c.1 Water efficient landscaping (reduce by 50 %, captured rainwater) Calculation • WE c.2 Innovative wastewater technologies (e.g. gray water) Calculation • WE c.3. Water use reduction (high efficiency fixtures – 20-30% reduction) • Calculation K&H BANKSZÉKHÁZ ISMERTETÉSE K&H HEADQUARTERS

  26. EXAMPLE: Water efficient landscaping K&H BANKSZÉKHÁZ ISMERTETÉSE K&H HEADQUARTERS

  27. ENERGY AND ATHMOSPHERE • ENERGY AND ATHMOSPHERE • Aim: reduction of the amount of energy required and use of more benign form of energy • Responsible: • HVAC engineer • Submittal documentations: • Confirmations • Calculations K&H BANKSZÉKHÁZ ISMERTETÉSE K&H HEADQUARTERS

  28. ENERGY AND ATHMOSPHERE • ENERGY AND ATHMOSPHERE • EA P1 Prerequisite: Fundamental commissioning of the building energy system • EA P2 Minimum energy performance (establishment of the minimum energy efficiency for the building – SHRAE/IESNA) • EA c1 Optimize energy performance (energy simulation, cost savings: 10,5-42%) Calculation • EA c2 On-site Renewable Energy (2,5-12,5%) Calculation • EA c3 Enhanced commissioning (commissioning process from the design phase till the verification of completed system) Confirmation • EA c4 Enhanced Refrigerant management (reduce ozone depletion – refrigerants!) Confirmation • EA c5 Measurement & verification (monitoring of the building energy consumption) Confirmation • EA c6 Green power (35% of electricity from renewable energy) Calculation K&H BANKSZÉKHÁZ ISMERTETÉSE K&H HEADQUARTERS

  29. EXAMPLE: Optimize energy performance K&H BANKSZÉKHÁZ ISMERTETÉSE K&H HEADQUARTERS

  30. MATERIALS AND RESOURCES • MATERIALS AND RESOURCES • Aim: use of recycled-content materials, local materials, collection of recyclables • Responsible: • Investor • Architect • Building contractors • Submittal documentations: • Confirmations • Calculations K&H BANKSZÉKHÁZ ISMERTETÉSE K&H HEADQUARTERS

  31. MATERIALS AND RESOURCES • MATERIALS AND RESOURCES • MR P1 Prerequisite: Storage & collection of recyclables • MR c2 Construction waste management Calc. & confirm. • MR c4 Recycled content (10-20% based on cost) Calc. & confirm • MR c5 Regional materials (extracted and manufactured within 500 miles, 10-20% based on cost) Calc. & confirm • MR c7 Certified wood (50% certified according to the Forest Stewardship Council’s principles) Calc. & confirm K&H BANKSZÉKHÁZ ISMERTETÉSE K&H HEADQUARTERS

  32. EXAMPLE: Storage & collection of recyclables K&H BANKSZÉKHÁZ ISMERTETÉSE K&H HEADQUARTERS

  33. INDOOR ENVIRONMENTAL QUALITY • INDOOR ENVIRONMENTAL QUALITY • Aim: more healthy and comfortable working conditions for occupants • Responsible: • Investor • Architect • HVAC engineers • Electrical engineers • Submittal documentations: • Confirmations • Calculations K&H BANKSZÉKHÁZ ISMERTETÉSE K&H HEADQUARTERS

  34. INDOOR ENVIRONMENTAL QUALITY • INDOOR ENVIRONMENTAL QUALITY • EQ P1 Minimum Indoor Air Quality Performance (according to ASHREE) • EQ P2 Environmental tobacco smoke control (non smoking building) • EQ c1 Outdoor air delivery monitoring (CO2 monitoring) Confirmation • EQ c2 Increased ventilation (30% above minimum rates ofASHREE) Calculation • EQ c3 Construction IAQ management plan (wraped air-ducts)Confirmation • EQ c4 Low emitting materials (reducing of odorous, irritating or harmful contaminants of indoor air – adhesives, sealants) Confirmation • EQ c5 Indoor chemical & pollutant source control (entryway system, negative pressure for copy areas) • EQ c6 Controllability of systems (by individual occupants, or specific groups – operable windows, shading system control etc.) Confirmation • EQ c 7 Thermal comfort (comfortable thermal environment according ASHRAE) • EQ c8 Daylight and views (75% daylight 90% view) Calculation K&H BANKSZÉKHÁZ ISMERTETÉSE K&H HEADQUARTERS

  35. EXAMPLE: Daylight and views K&H BANKSZÉKHÁZ ISMERTETÉSE K&H HEADQUARTERS

  36. TAMÁS JÁNOS SZABÓ DLA, FINTA & PARTNERS ARCHITECTURAL STUDIO Ltd. THANK YOU FOR YOUR KIND ATTENTION