1 / 33

WEL COME

WEL COME. SURFACE WATER STATE DATA CENTRE, MAHARASHTRA. Arabian sea. WEST COAST RIVERS. Goa. WATER QUALITY DATA ENTRY DATA VALIDATION. S.K.KSHIRSAGAR. DATA RECORD. FIELD TESTS B) GENERAL C) NUTRIENTS D) ORGANIC MATTER E) ALKALINITY. Data Record. DATA RECORD. F) HARDNESS

Download Presentation

WEL COME

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. WEL COME

  2. SURFACE WATER STATE DATA CENTRE, MAHARASHTRA

  3. Arabiansea WEST COAST RIVERS Goa

  4. WATER QUALITY DATA ENTRY DATA VALIDATION S.K.KSHIRSAGAR

  5. DATA RECORD • FIELD TESTS • B) GENERAL • C) NUTRIENTS • D) ORGANIC MATTER • E) ALKALINITY

  6. Data Record DATA RECORD • F) HARDNESS • G) MAJOR IONS • H) OTHER INORGANIC • COLIFORMS • J) BIOLOGICAL

  7. DATA VALIDATION • DATA VALIDATION – SWDES ONLY • 2) NO ACCESS TO HYMOS FOR W.Q.DATA • 3) VALIDATION IS ON THE BASIS OF PARAMETERS CO-RELATION BETWEEN pH , D.O. BOD,COD etc

  8. DATA VALIDATION DATA VALIDATION FACTORS AFFECTING W.Q.VALIDATION 1)SAMPLING TECHNIQUES 2) FIELD DETERMINATION 3) PRESEVATION IN FIELD 4) PEROD OF SAMPLE RECEIPT TO LAB 5) TREATMENT IN LAB

  9. DATA VALIDATION DATA VALIDATION FACTORS AFFECTING W.Q.VALIDATION FACTORS AFFECTING W.Q.VALIDATION 6) MISSING PARAMETER 7) PARAMETERS IN CUSTOMISED MENU ( LIKE TURBIDITY ) 8) SHORT INFORMATION ENTERED IN ID FORM & ANALYSIS RESULTS

  10. DATA VALIDATION DATA VALIDATION FIRST VALIDATION MINIMUM & MAXIMUM VALUES SERVE AS A FIRST VALIDATION

  11. DATA VALIDATION DATA VALIDATION SECOND VALIDATION UWL & LWL PROVIDED IN THE SOFTWARE TO WARN THE USER

  12. DATA VALIDATION SECOND VALIDATION UWL & LWL UWL < or = MAX LWL > or = MIN PREVENT DATA ENTRY/ BUT DISPLAY WARNING SYMBOL

  13. DATA VALIDATION THIRD VALIDATION LOD :- LIMIT OF DETECTION USED ONLY FOR VALIDATIONPURPOSE IN CASE OF TRACE METALS AND TRACE ORGANICS VALUE < LOD ( Alt-t)

  14. DATA VALIDATION DATA REQUIRED • A) CATIONS – Ca , Mg , Na , K • B) ANIONS – Cl , SO4 , CO2 , HCO2 , NO2 , NO3 • C) TOTAL CATIONS – • D) TOTAL ANIONS –

  15. DATA VALIDATION 1) ION BALANCE :- C – D / C + D 2) ION BALANCE :- Na / Cl 3) EC BALANCE :- TDS / EC 4) CARBON BALANCE :- COD / BOD 5) CO3 BALANCE :- IF pH < 8.3 PHEN ALKALINITY = 0?

  16. DATA VALIDATION DATA VERIFICATION CRITERIA • ION BALANCE < 0.1 • 2) ION BALANCE = 0.8 – 1.2 • 3) EC BALANCE = 0.55 – 0.9 • 4) CARBON BALANCE – 1-10 • 5) CO3 BALANCE = YES ( OK )

  17. DATA VALIDATION 1)Checked By – Here the responsible person or the head of Laboratory,should put his name or initials after checking the outcome of the validation 2) Remarks :- In this field the person who has checked the data may put some remarks i.e. to explain why a sample did not pass a validation check.

  18. DATA VALIDATION SOME KEY POINTS • If sample did not pass the validation check then it is required to reanalyze the sample( If sufficient quantity of collected Sample is available) otherwise reject the sample and collect new sample.

  19. DATA VALIDATION SOME KEY POINTS 2) In such cases it is necessary to see the following aspects i) Check manuscript copy of data ii) Validation should be done manually before entering the data & do not allow to enter the data in the computer before satisfactory manual validation

  20. DATA VALIDATION SOME KEY POINTS iii) Check ERRORS in instruments, Calculations, Check chemist register, Life of stock solution, Type of distilled water, Calibration of instruments, Analytical procedure adopted

  21. Adding Customized Parameters TURBIDITY

  22. Water Quality Data Entry in SWDES Adding Customized Parameters is a part of Validation ( ie,Missing Parameter in Data Entry)

  23. Adding Customized Parameters STEPS

  24. 1)Open Option “Laboratory Information”

  25. Select Laboratory

  26. Select “ General Parameter”Option

  27. Select “ General Parameter”Option & Select Desire Parameter

  28. “Turbidity” is Selected

  29. Open Menu”Sample Data Entry and Validation register

  30. Select Menu” Customized Parameters”

  31. Parameter TURBIDITY is Selected

  32. ENTER THE RESULTS OF TURBIDITY IN THE CUSTOMISED PARAMETER MENU

  33. THANK YOU