Efficiency calibration of a Germanium gamma-ray detector using GEANT4

Efficiency calibration of a Germanium gamma-ray detector using GEANT4. Santiago Hurtado *, Manuel García-León*, Rafael García-Tenorio**. * Dpto. Física Atómica, Molecular y Nuclear ** Dpto. Física Aplicada I Universidad de Sevilla. Detector geometry. REGe (Reverse Electrode Germanium).

annebailey
Download Presentation

Efficiency calibration of a Germanium gamma-ray detector using GEANT4

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Efficiency calibration of a Germanium gamma-ray detector using GEANT4 Santiago Hurtado*, Manuel García-León*, Rafael García-Tenorio** * Dpto. Física Atómica, Molecular y Nuclear ** Dpto. Física Aplicada I Universidad de Sevilla 19th July 2002, Salamanca

  2. Detector geometry REGe (Reverse Electrode Germanium) Be window D Ge tf L d th r R 19th July 2002, Salamanca

  3. Experimental setup Radionuclides: 210Pb, 241Am, 137Cs, 40K, 133Ba, 152Eu 15 cm Point source Marinelli beaker 19th July 2002, Salamanca

  4. Simulation Class diagram REGePrimaryGenerator particleGun GSPM GenerateBiasFlux ROOT-C++ REGeRunAction Histogramfilename REGeVisManager RegisterGraphicsSystem ->VRML1FILE REGeDetectorConstruction G4Tubs,G4Material,... ->REGe geometry setup REGeCristalSD HitsCollection REGePhysicsList Cut values , e- and e+ LowEnergyPhysics REGeEventAction HitsCollection-> Histogramfilename REGeCristalHit Hit-> Pos,Edep,weight REGe 19th July 2002, Salamanca

  5. Variance Reduction technique Zone II algorithm r R min (x,y,z) Zone II Zone I max Ge H Zone III Zone IV Zone V 19th July 2002, Salamanca

  6. Computing time reduction 19th July 2002, Salamanca

  7. ROOT-C++ Analysis Histogram FWHMexp MC Area calculation 19th July 2002, Salamanca

  8. Point results 19th July 2002, Salamanca

  9. Marinelli results 19th July 2002, Salamanca

  10. Optimized geometry & Efficiency transfer D Ge tf L th d r D, R -> 240Am , 210Pb , 133Ba (POINT) L -> 240Am , 210Pb (MARINELLI) d, r, th -> 137Cs , 40K (POINT-MARINELLI) D+2 mm , R-0.75 mm , L-3 mm , D-3 mm , r+2 mm R 19th July 2002, Salamanca

  11. Conclusions • GEANT4 provides a good agreement: exp. & MC data • GEANT4 is useful to setup complicated experimental geometries • Versatility of GEANT4 (C++) improves lab experiments (coincidence- summing, background simulation, ...) 19th July 2002, Salamanca