What caused the problem? What are the symptoms ? Solution (if any) …?

What caused the problem? What are the symptoms ? Solution (if any) …? Potential existence of same problem in similar circuits?. Quench-like trips of RSS.A78B1/2…. RSS.A78B1/2 tripped twice during pre-cycling/heat runs, indicating an increase of current just before tripping

Download Presentation

What caused the problem? What are the symptoms ? Solution (if any) …?

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. What caused the problem? • What are the symptoms ? • Solution (if any) …? • Potential existence of same problem in similar circuits?

  2. Quench-like trips of RSS.A78B1/2… RSS.A78B1/2 tripped twice during pre-cycling/heat runs, indicating an increase of current just before tripping RSS.A78B2 on 16th of February @ 04:16:56 at 400A during heat run/PGC RSS.A78B1 on 18th of February @ 02:19:26 at 400A during heat run/PGC RSS.A78B1 on 19th of February @ 01:07:48 at ~335A during heat run/PGC At first sight -> Looking like (and being mistakenly classified as) a quench, if not… Looking familiar?

  3. .. another one @ flat top…

  4. ..while ramping…

  5. Cross-talk @ 400A • During heat runs and PGCs, the normal cross-talk can be observed (different to RCO.A45B1..)

  6. How to diagnose… • Although not always as clearly visible, V_MEAS is a better signal to observe, suggesting sudden changes of impedance • With the loosening of the connection, also the I_ERR_MA significantly increases, mostly well before the circuit trip 1 min

  7. Similar on the flat top…

  8. …and the guilty one is… • Following the repetitive trips, EPC proceeded to exchange the power module and found… • …a loose bolt on the DCCT head, right next to the thyristor… • Note: EPC verified that even without the tightening bolt the circuit can NEVER completely open

  9. How to detect other case? • Are similar cases possible in the machine -> Certainly YES • Can we detect them? YES, but needs special runs (few hours for the whole machine)… • The slower the loop is, the worse the rejection of perturbations will be • By putting all loops slower than usual (10 or 100 times), and running the circuit in DC state (80% of nominal current) one should be able to detect bad connection through verification of the I.ERROR (to be confirmed for circuits with >> time constants). 0.1V

  10. Thanks a lot for your attention 10