silicon lab at sinp msu n.
Download
Skip this Video
Loading SlideShow in 5 Seconds..
Silicon Lab at SINP MSU PowerPoint Presentation
Download Presentation
Silicon Lab at SINP MSU

Loading in 2 Seconds...

play fullscreen
1 / 31

Silicon Lab at SINP MSU - PowerPoint PPT Presentation


  • 151 Views
  • Uploaded on

Silicon Lab at SINP MSU. Michael Merkin. Silicon Lab @ SINP MSU. Main goals: Silicon detectors design and development, Front-end electronics for silicon detectors 16 year experience on silicon detectors and relation with microelectronic industry 5 scientists

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Silicon Lab at SINP MSU' - zizi


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
silicon lab at sinp msu

Silicon Lab at SINP MSU

Michael Merkin

PHENIX Meeting, Prague

silicon lab @ sinp msu
Silicon Lab @ SINP MSU
  • Main goals: Silicon detectors design and development, Front-end electronics for silicon detectors
  • 16 year experience on silicon detectors and relation with microelectronic industry
  • 5 scientists
  • 6 engineers (electronics, mechanics)
  • 2 programmers ( on-line, off-line)
  • 2 technicians

PHENIX Meeting, Prague

slide3

Silicon Lab @ SINP MSU

  • SiLab has almost all necessary equipment for detectors’ measurements.
  • 2 automatic probe stations (RADAR and A4).
  • 2 manual probe stations.

PHENIX Meeting, Prague

slide4

RADAR Automatic Probe Station

PHENIX Meeting, Prague

radar automatic probe station
RADAR Automatic Probe Station

PHENIX Meeting, Prague

a4 automatic probe station
A4 Automatic Probe Station

PHENIX Meeting, Prague

a4 automatic probe station1
A4 Automatic Probe Station

PHENIX Meeting, Prague

manual probe station
Manual Probe Station

PHENIX Meeting, Prague

manual probe station1
Manual Probe Station

PHENIX Meeting, Prague

silicon lab @ sinp msu1
Silicon Lab @ SINP MSU
  • Hadron-electron separator @ ZEUS (DESY), 10 m2, 10,000 R/O channels
  • Advanced Thin Ionization Calorimeter (ATIC) - Balloon Experiment, Antarctica
  • Forward part of D0 (FermiLab) silicon tracker – H-disks, 144,000 R/O chs
  • Nose Cone Calorimeter for Phenix experiment at RHIC (BNL)

PHENIX Meeting, Prague

silicon lab @ sinp msu2
Silicon Lab @ SINP MSU

Main Experiments

  • SVD-2 – open charm experiment on U-70 at IHEP (Protvino)
  • AMS-2
  • ECAL for Future Linear Collider (TESLA)
  • CBM (Compressed Baryonic Matter) Experiment at GSI (Darmstadt)

PHENIX Meeting, Prague

atic experiment
ATIC Experiment

PHENIX Meeting, Prague

d0 experiment fnal
D0 Experiment, FNAL

H-disk wedge for D0 Experiment

Completed H-disk

PHENIX Meeting, Prague

d0 experiment fnal1
D0 Experiment, FNAL

The first H-disk

PHENIX Meeting, Prague

d0 experiment fnal2
D0 Experiment, FNAL

The first H-disk

PHENIX Meeting, Prague

d0 experiment fnal3
D0 Experiment, FNAL

Large wedge

PHENIX Meeting, Prague

svd 2 25 m microstrip sensor
SVD-2 25μm microstrip sensor

PHENIX Meeting, Prague

slide18

TESLA/FLC/ILC

  • 4” high resistivity wafers
  • wafer thickness 525 m
  • sensor size: 62.0+0.0 -0.1 mm
  • scribe line: 60 m
  • active area size: 60.0
  • the dead zone width is about 1 mm

PHENIX Meeting, Prague

slide19

TESLA/FLC/ILC Sensors

PHENIX Meeting, Prague

slide20

TESLA/FLC/ILC Sensors

PHENIX Meeting, Prague

slide21

TESLA/FLC/ILC Sensors

PHENIX Meeting, Prague

slide22

Prototype Silicon Wafers For Calorimeter

62 mm

62 mm

Si Wafer :4x4 pads of detection

(15x15 mm2)

4” High resistive wafer : > 5 kcm

Thickness : 525 microns  3 %

Tile side : 62.0 + 0.0

- 0.1 mm

Guard rings – 4

In Silicon ~ 80 e-h pairs / micron  40000 e- /MiP

Capacitance : ~ 40 pF/pad

Leakage current : < 5 nA/pa4

Full depletion bias : <200 V

Nominal operating bias : 250 V

PHENIX Meeting, Prague

prototype w o fee
Prototype w/o FEE

PHENIX Meeting, Prague

prototype with fee boards
Prototype with FEE Boards

PHENIX Meeting, Prague

prototype with fee boards1
Prototype with FEE Boards

PHENIX Meeting, Prague

prototype with fee boards2
Prototype with FEE Boards

PHENIX Meeting, Prague

mip resolution
MIP resolution

Amplitude distribution for MIP (μ, p)

PHENIX Meeting, Prague

longitudinal e shower profile
Longitudinal e+ shower profile

PHENIX Meeting, Prague