ME 322: Instrumentation Lecture 16

ME 322: Instrumentation Lecture 16. February 26, 2014 Professor Miles Greiner. Announcements/Reminders. HW 6 due Friday No lab this week Career Fair, Tomorrow , February 27, 2014 Internships Prepare for permanent employment next year www.unr.edu/engineering/careerfair

zarifa
Download Presentation

ME 322: Instrumentation Lecture 16

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ME 322: InstrumentationLecture 16 February 26, 2014 Professor Miles Greiner

  2. Announcements/Reminders • HW 6 due Friday • No lab this week • Career Fair, Tomorrow, February 27, 2014 • Internships • Prepare for permanent employment next year • www.unr.edu/engineering/careerfair • Differential Fees pay for this

  3. Lab 6 Air Volume Flow Rate and Centerline Speed in a Wind Tunnel • Plexiglas Tube and Schedule-40 Pipe have different diameters • Control flow rate using a variable speed blower • Cover blower exit for very low speeds • For a range of flow rates, measure • Volume flow Q rate using a Presso Venturi Tube (in pipe) • Centerline speed VC using a Pitot-Static Tube (in Plexiglas tube) • For both measure pressures difference using calibrated transmitters/digital multimeters • Both VC and Q increase with blower flow rate • Is VS < VC < VP?

  4. Instrument Schematic Variable Speed Blower Plexiglas Tube Pitot-Static Probe VC Barometer PATM TATM Venturi Tube Q Pipe • Measure atmospheric conditions PATM and TATM • Using hand-held digital-barometer • = 0.5 kPa, = 1°C (95%?) • Need PStat to find pressure • Is PStat< = or > than PATM? • Use 40-in-WC transmitter to find Gage Pressure PG = PATM – PS • PS = PATM - PG • To measure Pitot-Static tube pressure difference PP • Use 3-in-WC transmitter • To measure Venturi tube pressure difference PV • Use 40-in-WC transmitter DTube DPipe PV - Static + 40 in WC Total PP PG Atm IV - - + + 3 in WC 40 in WC IG IP

  5. Summary • Before Experiment • Measure tube diameter • Calculate transmitter uncertainties • Use hand held barometer to measure • PATM • TATM • °C

  6. During Experiment • For each blower setting measure currents and find the values & uncertainties • Pressure Measurements • P = rgh = rg(FS)(I – 4mA)/16 mA • WP = 0.0025rg(FS) • Static Pressure, PStat = WOB (Work on Board) • WOB • WOB • Air density WOB • WOB • Volume flow rate WOB • WOB • Centerline speed WOB • WOB • Check Pipe Reynolds numbers, = • (300 K) • Venturi calibration (KPresso) is within 2% for 54,000 < < 137,000

  7. Consistency Check • For a given volume flow rate Q • VS = Q/A • VP = 2VS • What area should we use? • APipe or ATube

  8. Measured Results • Determine speed and flow rate uncertainty for a range of blower speeds

  9. Demonstrate Excel Calculations • Lab 6 Sample Data • http://wolfweb.unr.edu/homepage/greiner/teaching/MECH322Instrumentation/Labs/Lab%2006%20Fluid%20Flow/Lab%20Index.htm • Values and uncertainties • Pressure Units • Error Bars

  10. Pressure Transmitter Uncertainty • Pressure • = 998.7 kg/m3, g = 9.81 m/s2 • FS = (3 or 40 inch) • Manufacturer stated uncertainty: 0.25% Full Scale • (95%?) • For FS = 3 inch WC • PFS = rWghFS= (998.7 kg/m3)(9.81 m/s2) (3 inch) = 746.6 Pa • wP = 0.0025 PFS = 1.9 Pa • For FS = 40 inch WC • PFS = rWghFS= (998.7 kg/m3)(9.81 m/s2) (40 inch) = 9954 Pa • wP = 0.0025 PFS = 25 Pa

  11. Static Pressure • PStat = PATM – PG • Use for , RAir = 0.2870 kPa-m3/kg-K • So want PStat in [kPa] • Inputs • PATM • Measure using barometer • = 500 Pa = 0.5 kPa (95%) • PGAGE • Measure using 40 inch WC gage • = 25 Pa = 0.025 kPa (95%)

  12. Static Pressure Uncertainty • PStat = PATM – PG(Linear Sum?)

  13. Transmitter Pressures 3” or 40” WC

  14. Gas Pressure and Density

More Related