1 / 27

UES: Utrecht Echelle Spectrograph

UES: Utrecht Echelle Spectrograph. UES on the WHT Nasmyth platform. High-res. spectrograph (WHT 1992- 2002 ) Spectral range 300-1100nm Cross-dispersion, 3 prisms + 2 diffraction gratings Resolving power between 50.000 - 80.000. 2. UES optical design. 3m. 3m. 3.

yoshe
Download Presentation

UES: Utrecht Echelle Spectrograph

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. UES: Utrecht Echelle Spectrograph • UES on the WHT • Nasmyth platform. • . High-res. spectrograph (WHT 1992- 2002 ) Spectral range 300-1100nm Cross-dispersion, 3 prisms + 2 diffraction gratings Resolving power between 50.000 - 80.000 2

  2. UES optical design 3m 3m 3

  3. Optical elements + detector 4k x 4k Fairchildt Collimador Prisms (3) Gratings (2) Camera 4

  4. HORUS optical design 5

  5. pre-optics Microlense arrays (Amus) 50mm fibers (UV050125140, Ceramoptep) 6

  6. Acquisition arm 7

  7. Coupling to OSIRIS inside OSIRIS 8

  8. Design Image sliced on the Nasmyth focus into 12 square 357 m (0.43 arcsec) microlenses feeding 50 m diameter fibers 2 calibration fibers 4 sky fibers

  9. Light enclosed in fibers 66% 19% 84% at 1” 6% 57% at 1.5” 38% at 2”

  10. Performance • R ~ 50,000 (1.5-3.5 Å/mm and FWHM ~ 3 pixel) 16% throughput on blaze (0.4 original  0.65 fiber  0.8 pre-optics  0.90 folds  0.84@1”) • New detector is larger (40962 15 m) • 40 mm (x limited by corr. plate) 61 mm (y CCD) • ~ 1-2 m/s long-term precision 370-570 nm contiguous 570-900 nm partially (estimated)

  11. 10ºC<T<20ºC T stability GTC foundations ≈ 0.3 K T variations damped by x5 Data (T, RH) being taken since February 2012 Planning a seismic study by Geology Dept. (ULL) Coudé room

  12. Isolating structure Al 3.15 x 2.5 x 2 m (38.4 m2) stability +/- 0.1K Ref. temperature TBD T = 10ºC implies losses 110w 250w chiller, 20l/min Environment

  13. Vacuum chamber • Stainless steel AISI 304 • 2.9m x 1.6m (1.5m Ø) • mass 1320 Kg • 4 isomatic dampers • Thermal transmission (238w/K): • conduction: 96w/K • convection: 140w/K • radiation (net): 2w/K

  14. All optical elements at a constant temperature (TBD) 3 hangers to join bench to chamber (G10). Thermal transmission (6w/K): Conduction: 5.3w/K Convection: NA (pressure under 200 mTorr) Radiation (net): 0.7w/K Optical bench

  15. HORUS data reduction and analysis software • Basic processing: bias, flatfielding • Extraction: standard, optimal, perfectionism • Calibration: flux (rough), wavelength (critical) • RVs: cross-correlation, template matching, research! • Spectral classification: stars, galaxies, clusters • Stellar parameters: Teff, logg, [Fe/H], micro, [ /Fe] …

  16. HORUS-P

  17. HORUS-P

  18. The 2 UES gratings 19

  19. Zooming-in 20

  20. Science CCD Lab data

  21. Science Lab data Na-Ar Na-Ne Th-Ar

  22. Lab studies • Stability with temperature • Stability with image • Spectrophotometric precision • Solar center-to-limb variation Shift (pixels) Frame #

  23. HORUS • Estimates indicate 2 years of work and 350 000 euros needed • Have used internal (IAC) funding for design studies and some components (200 000 euros for detector from Spectral Instruments + about 15000 euros recently for design and fibers and hardware) • IAC internal (Severo Ochoa) funding secured (200 000 euros) • Vacuum chamber is delayed: internal review + funding issues • Attractive alternative is to take it under a simplified form to GTC while vacuum-chamber development continues

  24. HORUS • Most high-resolution science projects do not require extreme stability • Pre-optics can be optimized for poor seeing conditions that GTC cannot use effectively now • HORS can use Nasmyth platform: it fits and with a shorter length (reduced losses) • Essentially ready to go!

  25. HORUS issues • Wavelength calibration: can use ICM? otherwise a supply from IACUB) • CCD had faulty electronics: now solved • CCD cryocooler: can be stored in isolated cabinet • Fiber-fed. Fibers in hand. Several fiber links produced for lab tests • Acquisition electronics: working, if too simple • Missing folder: on lease from P. L. Palle (solar lab at Teide Observatory) calibration unit is needed (ThAr hollow-cathode + power

More Related