INTRODUCTION

INTRODUCTION. HISTORY First Introduced in 1996 Edition Special Section in 2000 Edition (8.9) TEN YEARS OF PRACTICE Learning Curve Problems Encountered. SECTION 8.9. Requirement 8.9 contains requirements for all new and existing equipment within the Scope of this Code. .

xanti
Download Presentation

INTRODUCTION

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CodeDataPlate.com

  2. INTRODUCTION • HISTORY • First Introduced in 1996 Edition • Special Section in 2000 Edition (8.9) • TEN YEARS OF PRACTICE • Learning Curve • Problems Encountered CodeDataPlate.com

  3. SECTION 8.9 Requirement 8.9 contains requirements for all new and existing equipment within the Scope of this Code. 8.9.1 Required Information Data plate shall be provided and maintained that shall indicate the Code to be used forinspections and tests (see 8.10.1.2). The data plate shall indicate the Code and edition in effect at the time of installation. The data plate shall also indicate the Code in effect at the time of any alteration and indicate the applicable requirements of 8.7. CodeDataPlate.com

  4. Edition Sensitive Items(85 years of code) • A17.3 applies from d-1986 through d-2000 to Part XII • Item 1.6 Car Emergency Signal there are 6 differences • Space Guards A17.1-1937 and later editions (also A17.3) • Static Control a-1988 and later editions • Glazing b-1989 and later editions & again in a-2005 • Item 1.12/13 & 3.8 (Cab items) there are 16 differences • and 16 more relating to car & hoistway doors & gates • Door Restrictors b-1980, b-1983 and b-1989 differences • Hydro RPR required for installations under c-1986 and later • Fire Service b-1973, 1981, 1984, b-1989 and 2000 CodeDataPlate.com

  5. CDP Flow Chart CodeDataPlate.com

  6. STANDARD PLATESIN STOCK • CODE YEARS 1921 TO PRESENT CodeDataPlate.com

  7. Reading the Plate Door Operator Plunger Gripper Wiring Valve Pump Unit Re-opening Devise Tank Door Restrictor Limits Controller Replacement Top of Car Insp.. Emergency Operations Leveling CodeDataPlate.com

  8. CodeDataPlate.com

  9. CodeDataPlate.com

  10. Job Information Web, e-mail, phone or fax

  11. CodeDataPlate.com

  12. 43 AHJ’s Data Base of Effective Dates CodeDataPlate.com

  13. Custom Software CodeDataPlate.com

  14. Custom Software CodeDataPlate.com

  15. Other Types of Plates • Job Specific Plates • ADJ Specific Plates • NYC - Ohio -Iowa • Mass. - Calif. -WA • Penn. - MO -A17.3 • Add on Plates • Cross-head Plates • T/H plates CodeDataPlate.com

  16. Under b-1995 and earlier Other Products Hydro Under 1996 and later Replacement Crosshead Plates CodeDataPlate.com

  17. Other Products CodeDataPlate.com

  18. Code Data Plate Kit Other Products CodeDataPlate.com

  19. Pocket Code CodeDataPlate.com

  20. Other Products Now Available CodeDataPlate.com

  21. New Inspection Tags - 8.11.1.6 Courtesy of Zack McCain Now Available CodeDataPlate.com

  22. Now Available Field Marked Alteration Plate Covers common alterations CodeDataPlate.com

  23. Under Development Section 2.11 of A17.7 CodeDataPlate.com

  24. Other Issues • Magic Marker Plates • Foil Plates • Mounting Locations • External Plate for Escalators - 2007 code • TN 07-1083 • Securely fastened • Permanently legible • Durable mean to prevent loss of data or • Raised or depressed .8 mm (.03125 in) • Rationale: Assure information is available for life of equipment CodeDataPlate.com

  25. Conforming Plates CodeDataPlate.com

  26. Discussion • As Inspectors what are you seeing? • What percent of units have proper information? • Is it on a compliant plate? • What can we do to offer a better product? • What is Helpful? • What is not? CodeDataPlate.com

  27. Thank You CodeDataPlate.com