EFFECT OF PHYSIOLOGICAL FLUIDS. Biocompatibility plays a very important role on deciding the life of biomaterials. A completely "biocompatible" material would not irritate the surrounding structures provoke an inflammatory response initiate allergic reactions cause cancer.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'EFFECT OF PHYSIOLOGICAL FLUIDS' - walker


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
slide1

EFFECT OF PHYSIOLOGICAL FLUIDS

  • Biocompatibility plays a very important role on deciding the life of biomaterials.
  • A completely "biocompatible" material would not
    • irritate the surrounding structures
    • provoke an inflammatory response
    • initiate allergic reactions
    • cause cancer

BIOMATERIALS

slide2

EFFECT OF PHYSIOLOGICAL FLUIDS

  • A "biocompatible" material should also not have its
  • properties degraded from an attack by the body's immune
  • system.
  • The term biocompatible suggests that the material
  • described displays good or harmonious behavior in contact
  • with tissue and body fluids.
  • Water constitutes a major portion of the fluids and these
  • react with the surface of the materials.
  • The interaction of water or in general other fluids affects the
  • properties of materials.

BIOMATERIALS

slide3

EFFECT OF PHYSIOLOGICAL FLUIDS

  • Water is the universal ether dissolving inorganic salts and
  • large organic macromolecules such as proteins.
  • Water suspends living cells as in blood and is the principal
  • constituent of all interstitial fluids.
  • It is believed that water is the first molecule to contact
  • biomaterials in any clinical application.
  • Due to water, the hydrophobic effect ,hydrophilic effect and
  • surface wetting effect occurs.

BIOMATERIALS

slide4

EFFECT OF PHYSIOLOGICAL FLUIDS

  • The hydrophobic effect is related to the insoloubility of
  • hydrocarbons in water and is the fundamental of lipids.
  • In other words, the hydrophobic effect is the property that
  • nonpolar molecules like to self-associate in the presence of
  • aqueous solution.
  • The hydrophobic effect is the fundamental life giving
  • phenomena attributed to water.
  • Hydrocarbons are sparingly soluble in water because of the
  • strong self association of water.

BIOMATERIALS

slide5

EFFECT OF PHYSIOLOGICAL FLUIDS

The hydrophilic effect refers to a physical property of a

molecule that can transiently bond with water (H2O) through

hydrogen bonding.

This is thermodynamically favorable, and makes these

molecules soluble not only in water, but also in other polar

solvents.

The hydrophilic solutes exhibit Lewis acid or base strength

comparable to or exceeding that of water, so that it is

energetically favorable for water to donate electron density

to or accept electron density from hydrophilic solutes

instead of, or at least in competition with, other water

molecules.

BIOMATERIALS

slide6

EFFECT OF PHYSIOLOGICAL FLUIDS

Generally speaking the free energies of hydrophilic

hydration are greater than that of hydrophobic hydration.

As in hydrophobic effect, size plays abig role in the

salvation of hydrophilic ions.

Small inorganic ions are completely ionized and lead to

separately hydrated ions.

BIOMATERIALS

slide7

EFFECT OF PHYSIOLOGICAL FLUIDS

The interaction of water with the surfaces leads to surface

wetting effect.

The surface on which water spreads is called hydrophilic

and those on which water droplets form is called

hydrophobic.

Thus hydrophobic surfaces are distinguished from

hydrophilic by virtue of having no Lewis acid or base

functional groups available for water interaction.

BIOMATERIALS

slide8

EFFECT OF PHYSIOLOGICAL FLUIDS

Structure and solvent properties of water in contact with

surfaces between these extremes must then exhibit some

kind of properties associated with the graded wettability

observed with contact angles.

If the surface region is composed of molecules that hydrate

then the surface can adsorb water and swell or dissolve.

At the extreme of water- surface interactions,surface acid or

base groups can abstract hydroxyls or protons from water

leading to water ionization on the surface.

BIOMATERIALS

slide9

EFFECT OF PHYSIOLOGICAL FLUIDS

  • The surface energetics drives adsorption of water and then
  • in subsequent steps, proteins and cells interact with the
  • resulting hydrated surface.
  • Self association of water through hydrogen bonding is the
  • essential mechanism behind the water solvent properties.
  • As mentioned these interactions leads to the degradation of
  • the biomaterials.
  • It can be concluded that no theory explaining the biology of
  • materials can be complete with out accounting for the water
  • properties near surfaces.

BIOMATERIALS

slide10

BIOLOGICAL RESPONSES

  • The Biological environment is surprisingly harsh and can
  • lead to rapid or gradual breakdown of many materials.
  • Superficially, one might think that the neutral pH, low salt
  • content, and modest temperature of the body would
  • constitute a mild environment.
  • However, many specialized mechanisms are brought to
  • bear on implants to break them down.
  • These are mechanisms that have evolved over millennia
  • specifically to rid the living organism of invading foreign
  • substances and they now attack our contemporary
  • biomaterials.

BIOMATERIALS

slide11

BIOLOGICAL RESPONSES

  • The biological response can occur both in extravascular and
  • intravascular system.
  • The former deals with the changes outside the blood or lymph
  • vessel and the latter deals with in the blood vessels.
  • Let us consider that, along with the continuous or cyclic stress
  • many biomaterials are exposed to, abrasion and flexure may
  • also take place.
  • This occurs in an aqueous, ionic environment that can be
  • electrochemically, active to metals and plasticizing (softening)
  • to polymers.

BIOMATERIALS

slide12

BIOLOGICAL RESPONSES

  • Then, specific biological mechanisms are invoked.
  • Proteins adsorb to the material and can enhance the

corrosion rate of metals.

  • Cells secrete powerful oxidizing agents and enzymes that

are directed at digesting the material.

  • The potent degradative agents are concentrated between

the cell and the material where they act undiluted by the

surrounding aqueous.

BIOMATERIALS

slide13

BIOLOGICAL RESPONSES

  • To understand the biological degradation of implant
  • materials, synergistic pathways should be considered.
  • Swelling and water uptake can similarly increase the number
  • of site for reaction.
  • Degradation products can alter the local pH, stimulating
  • further reaction.
  • Hydroxyl polymers can generate more hydrophilic species,
  • leading to polymer swelling and entry of degrading species
  • into the bulk of the polymer.
  • Cracks might also serve as sites initiating calcification.

BIOMATERIALS

slide14

BIOLOGICAL RESPONSES

  • Biodegradation is a term that is used in many contexts.
  • It can be engineered to happen at a specific time after

implantation, or it can be un unexpected long-term

consequent of the severity of the biological Degradation is

seen with metals, polymers, ceramics and composites.

  • Biodegradation as a subject is broad in scope and rightfully

should command considerable attention for the bio

materials scientist.

BIOMATERIALS

slide15

BIOLOGICAL RESPONSES

Most biomaterials of potential clinical interest typically elicit

the foreign body reaction (FBR) a special form of non

specific inflammation.

The most prominent cells in the FBR are macrophages,

which attempt to phagocytose the material degradation are

often difficult.

The inflammatory cell products that are critical in killing

microorganisms can damage tissue adjacent to foreign

bodies.

BIOMATERIALS

slide16

BIOLOGICAL RESPONSES

  • Tissue interactions can be modified by,
    • changing the chemistry of the surface.
    • inducing roughness or porosity to enhance physical

binding to the surrounding tissues.

    • incorporating a surface-active agent to chemically bond

the tissue.

    • using a bioresorbable component to allow slow

replacement by tissue to simulate natural healing

properties .

BIOMATERIALS

slide17

BIOLOGICAL RESPONSES

  • The nature of the reaction is largely dependent on the
  • chemical and physical characteristic of the Implant.
  • For most inert biomaterials, the late tissue reaction is
  • encapsulation by a rel­atively thin fibrous tissue capsule
  • (Composed of collagen and fibroblasts).

BIOMATERIALS

slide18

CLASSIFICATION OF BIOMATERIALS

  • Biomaterials can be divided into three major classes of materials:
  • Polymers
  • Metals
  • Ceramics (including carbons, glass ceramics, and glasses).

BIOMATERIALS

slide19

METALLIC IMPLANT MATERIALS

  • Metallic implants are used for two primary purposes.
  • Implants used as prostheses serve to replace a portion of
  • the body such as joints, long bones and skull plates.
  • Fixation devices are used to stabilize broken bones and
  • other tissues while the normal healing proceeds.

BIOMATERIALS

slide20

METALLIC IMPLANT MATERIALS

  • Though many metallic implant materials are available commercially. The three main categories of metals which are used for orthopedic implants
  • Stainless steels
  • Cobalt-chromium alloys
  • Titanium alloys
  • will be discussed in detail.

BIOMATERIALS

slide21

METALLIC IMPLANT MATERIALS

  • The Metallic implant materials that are used should have the following characteristic features:
  • Must be corrosion resistant
  • Mechanical properties must be appropriate for desired
  • application
  • Areas subjected to cyclic loading must have good fatigue
  • properties

BIOMATERIALS

slide22

STAINLESS STEEL

  • Stainless steel is the predominant implant alloy.
  • This is mainly due to its ease of fabrication any desirable variety of mechanical properties and corrosion behavior.
  • But, of the three most commonly used metallic implants namely
    • Stainless steel
    • Cobalt chromium alloys
    • Titanium alloys,
  • Stainless steel is least corrosion resistant.

BIOMATERIALS

slide23

STAINLESS STEEL

  • The various developments which took place in the development of steel in metallic implants are discussed below.
  • Stainless steel (18Cr-8 Ni) was first introduced in surgery in
  • 1926
  • In 1943, type 302 stainless steel had been recommended to
  • U.S. Army and Navy for bone fixation.Later 18-8sMo stainless
  • steel (316), which contains molybdenum to improve corrosion
  • resistance, was introduced.
  • In the 1950s, 316L stainless steel was developed by reduction
  • of maximum carbon content from 0.08% to 0.03% for better
  • corrosion resistance.

BIOMATERIALS

slide25

STAINLESS STEEL

  • The chromium content of stainless steels should be least
  • 11.0% to enable them to resist corrosion.
  • Chromium is a reactive element.
  • Chromium oxide on the surface of steel provides excellent
  • corrosion resistance.
  • The AISI Group III austenitic steel especially type 316 and
  • 316L cannot be hardened by heat treatment but can be
  • hardened by cold working.
  • This group of stainless steel is non-magnetic and
  • possesses better corrosion resistance than any of the
  • others.

BIOMATERIALS

slide26

STAINLESS STEEL

  • The inclusion of molybdenum in types 316 and 316L
  • enhances resistance to pitting corrosion.
  • Lowering the carbon content of type 316L stainless steels
  • makes them more corrosion resistant to physiological saline
  • in human body.
  • Therefore 316L is recommended rather than 316 for implant
  • fabrication.

BIOMATERIALS

slide27

STAINLESS STEEL

  • The Stainless steels used in implants are generally of two types:
    • Wrought
    • Forged
  • Wrought alloy possesses a uniform microstructure with fine
  • grains.
  • In the annealed condition it possesses low mechanical
  • strength.Cold working can strengthen the alloy.
  • Stainless steels can be hot forged to shape rather easily
  • because of their high ductility.
  • They can also be cold forged to shape to obtain required
  • strength.

BIOMATERIALS

slide29

STAINLESS STEEL

  • Electroplating has been shown to be generally superior to a
  • mechanical finish for increasing corrosion resistance which
  • can also be produced by other surface treatments such as
  • passivation with HNO3.
  • The reason why stainless steel implants failed , indicates a
  • variety of deficiency factors like
      • deficiency of molybdenum
      • the use of sensitized steel

BIOMATERIALS

slide30

COBALT CHROMIUM ALLOYS

  • The two basic elements of Co-based alloys form a solid
  • solution of upto 65 wt % of CO and 35 wt % of Cr
  • To this Molybdenum is added to produce finer grains which
  • results in higher strength after casting or forging
  • Cobalt is a transition metal of atomic number 27 situated
  • between iron and nickel in the first long period of the
  • periodic table.
  • The chemical properties of cobalt are intermediate between
  • those of iron and nickel.

BIOMATERIALS

slide31

COBALT CHROMIUM ALLOYS

  • The various milestones in the development of cobalt chromium alloys are discussed below.
  • Haynes developed a series of cobalt-chromium and cobalt-
  • chromium-tungsten alloys having good corrosion resistance.
  • During early 1930s an alloy called vitallium with a composition
  • 30% chromium, 7% tungsten and 0.5% carbon in cobalt was
  • found.
  • Many of the alloys used in dentistry and surgery, based on the
  • Co-Cr system contain additional elements such as carbon,
  • molybdenum, nickel, tungsten

BIOMATERIALS

slide32

COBALT CHROMIUM ALLOYS

  • Chromium has a body centered cubic (bcc) crystal structure
  • and cannot therefore have a stability of the phase of cobalt.
  • The solubility of the former in the latter increases rapidly as
  • the temperature is raised.
  • Metallic cobalt started to find some industrial use at the
  • beginning of this century but its pure form is not particularly
  • ductile or corrosion resistant.
  • The various milestones in the development of cobalt
  • chromium alloys are discussed below.

BIOMATERIALS

slide33

COBALT CHROMIUM ALLOYS

  • Cobalt based alloys are used in one of three forms
  • Cast,
  • Wrought
  • Forged

BIOMATERIALS

slide34

COBALT CHROMIUM ALLOYS

  • Cast alloy: The orthopedic implants Co-Cr alloy are made by investment casting.In an investment casting process,the various steps which are involved are
  • a wax model of the implant is made and ceramic shell is built
  • around the wax model
  • When wax is melted away, the ceramic mold has the shape
  • of the implant
  • The ceramic shell is not fired is obtained the required the
  • mold strength
  • Molten metal alloy is then poured in to the shell, cooling, the
  • shell is removed to obtain metal implant.

BIOMATERIALS

slide35

COBALT CHROMIUM ALLOYS

Wrought alloy: The wrought alloy possess a uniform microstructure with fine grains. Wrought Co-Cr –Mo alloy can be further strengthened by cold work.

Forged Alloy: The Co-Cr forged alloy is produced from a hot forging process. The Forging of Co-Cr –Mo alloy requires sophisticated press and complicated tooling. These factors make it more expensive to fabricate a device from a Co-Cr-Mo forging than from a casting.

BIOMATERIALS

slide37

TITANIUM BASED ALLOYS

  • The advantage of using titanium based alloys as implant materials are
  • low density
  • good mechano-chemical properties
  • The major disadvantage being the relatively high cost and reactivity.

BIOMATERIALS

slide38

TITANIUM BASED ALLOYS

  • Titanium is a light metal having a density of 4.505g/cm3 at
  • 250C .
  • Since aluminum is a lighter element and vanadium barely
  • heavier than titanium, the density of Ti-6% Al-4% V alloy is
  • very similar to pure titanium.
  • The melting point of titanium is about 16650C although
  • variable data are reported in the literature due to the effect
  • of impurities.

BIOMATERIALS

slide39

TITANIUM BASED ALLOYS

  • Titanium exists in two allotropic forms,
  • the low temperature -form has a close-packed hexagonal
  • crystal structure with a c/a ratio of 1.587 at room temperature
  • Above 882.50C -titanium having a body centered cubic
  • structure which is stable
  • The presence of vanadium in a titanium-aluminium alloy tends to form - two phase system at room temperature.
  • Ti-6 Al-4V alloy is generally used in one of three conditions wrought, forged or cast.

BIOMATERIALS

slide40

TITANIUM BASED ALLOYS

  • Wrought alloy
  • It is available in standard shapes and sizes and is annealed
  • at 7300C for 1-4 hours, furnace cooled to 6000C and air-
  • cooled to room temperature.
  • Forged alloy
  • The typical hot-forging temperature is between 900°C and
  • 930°C.Hot forging produces a fine grained -structure with a
  • depression of varying  phase. A final annealing treatment
  • is often given to the alloy to obtain a stable microstructure
  • without significantly altering the properties of the alloy.

BIOMATERIALS

slide41

TITANIUM BASED ALLOYS

  • Cast alloy
  • To provide a metallurgical stable homogenous structure

castings are annealed at approximately 8400C .

  • Cast Ti-6 Al-4V alloy has slightly lower values for

mechanical properties than the wrought alloy.

Titanium and its alloys are widely used because they show

    • exceptional strength to weight ratio
    • good mechanical properties.

The lower modulus is of significance in orthopedic devices

since it implies greater flexibility.

BIOMATERIALS

slide42

TITANIUM BASED ALLOYS

  • To improve tribiological properties of Titanium there are four general types of treatments made.
  • Firstly, the oxide layer may be enhanced by a suitable

oxidizing treatment such as anodizing

  • Secondly, the surface can be hardened by the diffusion

of interstitial atoms into surface layers

  • Thirdly, the flame spraying of metals or metal oxides

on to the surface may be employed

  • Finally, other metals may be electroplated onto the

surface

BIOMATERIALS

slide43

TITANIUM BASED ALLOYS

BONE SCREWS USED FOR IMPLANTATION

BIOMATERIALS