1 / 1

Advanced PEI X-Ray Units with Cutting-Edge Safety Features and Digital Technology

PEI X-Ray units are state-of-the-art medical imaging devices designed with the latest electronic advancements, ensuring compliance with all necessary safety standards. These units feature a full digital display of radiographic factors like mA, mAS, and KVP, along with dynamic exposure interlocking based on tube ratings. The fully lead-lined tube head provides leakage radiation protection, while a solid-state timer guarantees optimal performance. Specifications include various mA capacities and flexible KVP settings, ensuring reliable and precise imaging for medical professionals.

ugo
Download Presentation

Advanced PEI X-Ray Units with Cutting-Edge Safety Features and Digital Technology

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. X-Ray Equipments PEI PEI X-Ray units are designed with latest electronic technology and keeping in mind all safety measures that are required for the specialised radio imaging equipments. Full Digital display of radiography factors viz. mA, mAS & KVP with dynamic interlocking of exposure as per the tube ratings. Leakage radiation proof , fully lead lined monobloc full wave rectified tube head as per BARC , IS 7620 & AERB standards. Solid state timer with delay restriction for proper boost up up the x-ray tube prior to any exposure. Space charge compensation for minimizing current losses at higher KV. Individual monitoring of both Line Voltage & mA output to monitor the line losses during exposure. Specifications 60 mA 100 mA 300 mA 500mA Mains Power 220 V AC 1-Ph , 6 KW 220 V AC 1-Ph ,10 KW 440 V AC 3-Ph , 32 KW 440 V AC 3-Ph , 50 KW X-Ray Tube Fixed Anode, Single Focus Fixed Anode, Single Focus Rotating Anode, Double Focus Rotating Anode, Double Focus KVP Selector 35 - 100 35 - 100 35 - 100 35 - 125 mA Selector 20,40 & 60 50,75 & 100 50,100. 100,150, 200 & 300 50, 100. 100,150, 200 & 300 Time (mAS ) 0.06 –10.0 0.06 -6.0 0.06 – 6.0 0.06 – 6.0 KVP Selector 35 - 100 35 - 100 35 - 100 35 - 125 mA Selector 0 – 5 0 – 5 0 – 5 0 – 5 Time 5 min. RESET 5 min. RESET 5 min. RESET 5 min. RESET PEI Medical Inc.

More Related