An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. S Department of Physics, University of Surrey, Guildford, GU2 7XH, UK M A Bero S J Doran W B Gilboy Investigation into the radiochromic (FXG) gel dosimeter:stability and uncertainty in optical measurements M A Bero, S J Doran and W B Gilboy Department of Physics University of Surrey

  2. Structure of talk • Historical perspective • Gel components and manufacture • Response of FXG compared with “traditional Fricke”dosimeter • Gel saturation and the effects of XO concentration • Gel stability • Gel reproducibility over time

  3. Historical perspective • Chemical dosimetry has a long history(Fricke and Hart “Radiation Dosimetry 1966) • [Fe3+] originally estimated by titration, then byUV spectrophotometry • Modification by using colour-change reaction first suggested in 1972 (Gupta, IAEA-sm-160, 421-432, 1972) • Initial applications to imaging of radiation dose in early 1990’s (e.g., Appleby and Leghrouz, Med. Phys. 18, 309-312, 1991) • Other investigations into dosimeter and its application (e.g., Gambarini, Kelly, Jordan, Wolodzko, Bero)

  4. Gel manufacture • Gel component of dosimeter • Gelatin (5% by final weight, 300 bloom) + 75% of total water • Highly transparent • Low melting point  little loss of dissolved oxygen • Macromolecule, enhances g-value for production of Fe3+ • Fricke chemicals • ferrous ammonium sulphate Fe(NH4)2(SO4)2.6H2O 0.5 mM • sulphuric acid H2SO4 25 mM • xylenol orange (sodium salt) C31H28N2O13 SNa4 0.1 mM • water (25% of total) “Milli-Q” reverse osmosis • Method • Leave gelatin to swell in cold water, dissolve at 45°C, stir for ~10 mins. • Mix Fricke chemicals at room temperature, combine with gel at ~35 °C.

  5. Dose-response of gel: (1) Comparison with traditional Fricke • Response of FXG approximately 23 times larger than standard Fricke solution • Highly linear dose response up to 30 Gy

  6. 0.1 mM Absorbance at 585 nm / cm-1 0.05 mM 0.025 mM 0.01 mM Dose / Gy Dose-response of gel: (2) Xylenol orange concentration • Changing the concentration of XO does not markedly alter the slope of the dose-response characteristic. • However, it does change the point at which saturation occurs.

  7. Dose-response of gel: (3) Effect of acid concentration 10 mM 25 mM 50 mM 100 mM * Absorbance at 585 nm / cm-1 Dose / Gy • Lowering the acid concentration increases the slope of the dose-response characteristic significantly.

  8. Stability of FXG gel: (1) Acid content 10 mM H2SO4 50 mM H2SO4 48 hr Absorbance / cm-1 “Immediate” 24 hr Dose / Gy • As the dose response improves, the stability degrades significantly. • An appropriate compromise is about 50 mM.

  9. 2.5 Dark in Fridge 2 Dark in lab Daylight in lab 1.5 Absorbance / cm-1 1 A = 710-4 t + 0.11 r2 = 0.993 0.5 0 0 200 400 600 800 Time after Irradiation (hours) Stability of FXG gel: (2) Storage conditions • Storage conditions affect the gel absorbance markedly. • For a refrigerated gel, in the dark, the change in absorbance is highly linear over a period of weeks.

  10. Reproducibility of gel dose-response 0 . 12 0 . 1 0 . 08 0 . 06 0 . 04 DRC slope at 585 nm Absorbance 0 . 02 DRC slope at 440 nm 0 1 3 5 7 9 11 13 15 17 19 21 23 - 0 . 02 - 0 . 04 - 0 . 06 FXG Batch Number • Intra-batch variability in dose-response (s/m) = 1.3% at 585 nm • Inter-batch variability = 10%, but includes changes in batches of raw materials.

  11. Conclusions • The FXG polymer gels are much easier to make than polymer gels. • FXG is much more sensitive than the original Fricke solution. • The concentration of acid is a balance between dose-response and stability. • Storage conditions are important. • Intra-batch repeatability is very good, but intra-batch repeatability has been relatively poor.