1 / 1

Tracheostomy Care Overlay System J. Biggs, D. Bond, N. Campagnola , E. Doll, N. Hott

Tracheostomy Care Overlay System J. Biggs, D. Bond, N. Campagnola , E. Doll, N. Hott Advisor: Dr. Liyun P. Wang Special Thanks to: Amy Cowperthwait. Background. Final Prototype. Prototype Testing and Validation.

trey
Download Presentation

Tracheostomy Care Overlay System J. Biggs, D. Bond, N. Campagnola , E. Doll, N. Hott

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Tracheostomy Care Overlay System J. Biggs, D. Bond, N. Campagnola, E. Doll, N. Hott Advisor: Dr. Liyun P. Wang Special Thanks to: Amy Cowperthwait Background Final Prototype Prototype Testing and Validation UD Healthcare Theatre Program: Simulation laboratories that are operational with real life patient simulators allowing nursing students to experience realistic patient care. The final design consists of two molded, thermop- lastic layers, encasing and protecting all of the inner components. These inclu-de the sensor system and lung sound speakers. To the right is the entire, assembled prototype. To test the design, a prototype of our final concept was built. This prototype allowed for testing of each component as well as system level testing. Additionally, testing was able to be performed with UD Healthcare theatre actors , as well as nursing students and Tracheostomy Care: Cleaning, replacing and suctioning of the tracheostomy tube, changing the dressing around the stoma, as well as cleaning the area around the stoma; all of which require minimal manipulation of the face plate. faculty to provide feedback on how realistic the device is, as well as its comfort and ease of use. The picture below shows the inner compone-ntsof the device. Sensor Threshold Tests Target threshold values were found through background research and testing with our sponsor Project Scope The UD Healthcare Theatre Program is looking to improve upon the current training mannequins by developing a wearable system for a real life patient simulator that will provide nursing students with realistic, tracheostomy care patient feedback during simulations. Customer Survey Review Survey results showed that it functions well as a learning device, as the sensors identified improper tracheostomy care accurately and the alerts can only be detected by the simulators. For comfort and ease of use, it was found that the device was easy to put on and take off, but that the comfort could be improved upon. Overall, the overlay system was thought to be more realistic, in appearance, than the current training mannequins and will enhance the tracheostomy care learning experience for nursing students. Design Requirements Concept Generation The following six needs are ranked according to importance: Lung Sound Speakers and Control: 1. Safety 2. Realistic 3. Ease of Use 4. Cost Effective 5. Durable 6. Comfort 1. Wireless control 2. Wired control Wireless control was chosen because it allowed for greater mobility and faster overlay set-up time Path Forward With funding from UD’s First Step Program, the team will continue to work on the overlay system by improving on the current prototype. The team will focus on improving the user interface for lung sound control, while also making the overlay more adaptable to a wider variety of body types. There will also be work done on the sensor system to increase individual sensor accuracy. After improvements have been made, the teamwill work on making the overlay more marketable with the ultimate goal of producing it on a large scale. Force/Rotation Detection: 2. Spring and Circuit Sensor: 1. Tactile Force Sensor Tactile force sensors were used due to the ability to give more accurate sensor readings and calibration

More Related