1 / 17

UV Sensitive very high PDE SiPMs with very low X-talk

This article discusses the development of UV sensitive SiPMs with high PDE (photon detection efficiency) and low cross-talk, as well as the challenges in accurately measuring PDE. The potential applications and improvements in suppressing cross-talk are also highlighted.

towery
Download Presentation

UV Sensitive very high PDE SiPMs with very low X-talk

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. UV Sensitive very high PDE SiPMs with very low X-talk Razmik Mirzoyan1, Pavel Buzhan2, Boris Dolgoshein2, Elena Popova2, Masahiro Teshima1 1- Max-Planck-Institute for Physics, Munich, Germany 2- National Research Nuclear University MEPhI, Moscow, Russia

  2. MEPhI - MPI for Physics R&D collaboration and cooperation with PerkinElmer Industries (now EXCELITAS) Developing UV sensitive SiPMs with extremely high PDE, Extremely low crosstalk and low dark rate SiPM Sizes 1x1 and 3x3 mm² µ-cell pitch 50 and 100 µm Geom. Eff. 40-80% Pioneer and great Leader: Prof., member of Russian Academy of Sciences Boris Dolgoshein 1930-2010 B. Dolgoshein, R. Mirzoyan, E. Popova, P. Buzhan, PEI, et al.,

  3. Current status of SiPM • Currently there is a lot of enthusiasm about the new devices but the deep understanding is not simple, it comes only slowly • One of the main problems of SiPMs is its low PDE, that is not easy to measure. It shall be disentangled from the cross-talk and after-pulsing. • The after-pulsing in PMTs is a ~1% effect on single ph.e. level, while for example, for currently existing MPPC’s from Hamamatsu it is a 20-30 % (depending on type and the applied over-voltage) effect. • Often the real value of PDE is significantly lower than the claimed (advertised) one. The reasons are a) the low applied overvoltage, b) neglecting of the cross-talk (X-talk) and c) of the after-pulsing. R. Mirzoyan: UV sensitive high PDE, low X-talk SiPM

  4. Still trying to understand The PDE of a SiPM can be presented as PDE(l) = Geiger-eff. x Geometry-eff. x Internal-QE x Transmission(l) Geiger-eff. = Function (applied-over-voltage); when Geiger-eff. saturates, one can obtain stable operation, also in the sense of temperature R. Mirzoyan: UV sensitive high PDE, low X-talk SiPM

  5. A PDE and gain of a 1x1 mm² SiPM test-sample produced by MEPhI-MPI cooperation; @+20°C Overvoltage = operational voltage – breakdown voltage (~31.5V) • As one can see on the right top the PDE of SiPM saturates at an over-voltage DV/V ~15 % • For higher applied • DV/V the gain (and the noise) will still increase but there will be no further increase of PDE • Hamamatsu MPPCs operate at maximum • DV/V < 3 % Overvoltage +20 % Overvoltage +15 % Overvoltage +10 % Overvoltage + 5 % R. Mirzoyan: UV sensitive high PDE, low X-talk SiPM

  6. Optical X-talk and afterpulsing and PDE • We need to learn how to • disentangle the X-talk • and the after-pulsing from • the genuine PDE. • One can see on the right • that depending on the PDE • measuring method, the • X-talk and afterpulsing • contributions together • could be as big as the • PDE by itself. R. Mirzoyan: UV sensitive high PDE, low X-talk SiPM

  7. Checking the universality of light emission (the culprit for X-talk) from different SiPM samples • We measured the absolute light emission of an MPPC of 3mmx3mm size from Hamamatsu and of 3mmx3mm and 1mmx1mm size SiPM test-samples from MEPhI-MPI design • As one would expect within errors all three samples emit the same light, the same spectrum R. Mirzoyan: UV sensitive high PDE, low X-talk SiPM

  8. Entire light emission spectrum of SiPM Mirzoyan, et al., NIM A 610, 2009 R. Mirzoyan: UV sensitive high PDE, low X-talk SiPM

  9. X-talk suppression is improving the performance • Known ways to • suppress X-talk: • trenches • 2nd junction • for isolating the • bulk from the • active region • new method, • shown on right  • d) special coatings (Patent pending) R. Mirzoyan: UV sensitive high PDE, low X-talk SiPM

  10. P. Buzhan, B. Dolgoshein, et al., NIM A 610, 2009 R. Mirzoyan: UV sensitive high PDE, low X-talk SiPM

  11. Ideal SiPM: a good wish or a reality, where are we ? Operating SiPM @ DV/V ~ 15 % Gain ≤ few x 106 Peak PDE ~ 60 – 65 % High PDE also in near UV (> 50 %) Timing ≤100 ps X-talk ≤ 1-2 % F-factor ≤ 1.02 After-pulsing ≤ 1-2 % Dark rate ≤ 0.5 MHz/mm² (room T°) Size1-10 mm² Low T ° dependence of gain, of PDE Scalable matrixes Signal processing on rear side R. Mirzoyan: UV sensitive high PDE, low X-talk SiPM

  12. Improved SiPMs • 18 different variations of SiPM (p over n) have been produced by MEPhI-MPI cooperation (with the support of PerkinElmer, now Excelitas) • Many innovative ideas were implemented R. Mirzoyan: UV sensitive high PDE, low X-talk SiPM

  13. Gain linearity Over-voltage, V R. Mirzoyan: UV sensitive high PDE, low X-talk SiPM

  14. X-talk for 1mmx1mm SiPM R. Mirzoyan: UV sensitive high PDE, low X-talk SiPM

  15. PDE for 1mmx1mm SiPM • When DV/V is set to • ~15 %, the Geiger efficiency • is saturated • As a result dependence • on T ° becomes very low, • it can be as low as • 0.5 %/ °C R. Mirzoyan: UV sensitive high PDE, low X-talk SiPM

  16. Conclusions • In a time scale of 1-2 years from now one can buy SiPMs with really outstanding characteristics, probably from several manufacturers. • Their sizes could span 1-10 mm (in remote future perhaps even larger) • SiPM cost will be reduced due to the availability of full CMOS designs. Several USD per mm² is not very unrealistic. • These devices are going to substitute classical PMTs and APD in many (but of course not all) applications, including those in physics instrumentation in, for example, nuclear medicine (time-of-flight PET,…). • We could demonstrate samples with max. PDE of 50-60 %, X-talk in the range of < 2-5 % and a very high PDE also in the UV when operated at ~15 % over-voltage R. Mirzoyan: UV sensitive high PDE, low X-talk SiPM

  17. Reminder: light absorption in Si • Absorption of light in Si • Already from this graph • one can get an impression • about the relevant for the • X-talk effect • wavelength range • Absorption length below • ~370 nm is below 10 nm R. Mirzoyan: UV sensitive high PDE, low X-talk SiPM

More Related