1 / 14

Referencias Diciembre 2010

Desmex – Sistemas Solares Térmicos. Referencias Diciembre 2010. Grupo DESMEX Instalaciones Solar Térmica. Sistema Para Agua Caliente Sanitaria y de Proceso Industrial, Toluca Edo. De Mexico 24 KW térmicos. Grupo DESMEX Instalaciones Solar Térmica.

torgny
Download Presentation

Referencias Diciembre 2010

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Desmex – Sistemas Solares Térmicos Referencias Diciembre 2010

  2. Grupo DESMEXInstalaciones Solar Térmica Sistema Para Agua Caliente Sanitaria y de Proceso Industrial, Toluca Edo. De Mexico 24 KW térmicos

  3. Grupo DESMEXInstalaciones Solar Térmica Sistema para Agua caliente, Hotel Best Western, Zacatecas, 30 KW térmicos

  4. Grupo DESMEXInstalaciones Solar Térmica Sistema Para Aire Acondicionado Industrial en Monterrey, NL. 40 KW térmicos

  5. Grupo DESMEXInstalaciones Solar Térmica Sistema Para Calefacción de Alberca, Hacienda en San Miguel de Allende, Gto. 19.2 KW térmicos

  6. Grupo DESMEXInstalaciones Solar Térmica Sistema Para Calefacción de Alberca y Agua Caliente en San Miguel de Allende, Gto. 14 KW térmicos

  7. Grupo DESMEXInstalaciones Solar Térmica Sistema Para Agua Caliente Sanitaria, San Miguel de Allende, Gto.

  8. Grupo DESMEXInstalaciones Solar Térmica Instalaciones varias de Termosifones para Agua caliente Sanitaria en toda la Republica

  9. Proyectos en Procesos Hotel Matilda , San Miguel de Allende, GTO. Hacienda / Hotel Ecológico Cañada de la Virgen, Gto. Caldera Piro tubular, UNILEVER Cuernavaca. Tequileras en Jalisco.

  10. EXAMPLE: Tequila factory: • The design parameters are as follows: • Design flow: 12530 Kg/Hr. • Temperature of the mixture in the condensation tank: 60°C. • Temperature of the mixture with the solar termal system: 80 °C • Required potential for the heating: 291 KW.

  11. Accordingtothelocation:

  12. system:

  13. It is recommended the camp of the 48 parabolic collectors PTC 1800 which represent the installed capacity of 218 kW in the area of 432 m2. • It is shown the average month solar production – data are adjusted with the meteorological data of the particular zone (Source: Meteonorm 6.1). • Thermal energy produced by the collectors: 478073 kWh • It is recommended the treatment by spraying the tank to adhere a layer of 3inches of isolation to conserve the produced energy.

More Related