An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Process Monitors and Controllers • The ProMinent DULCOMETER series combines a process monitor (analyzer) with automatic control capabilities • for nearly any water treatment process. • The series includes: • D1C single variable controllers • D2C dual variable controllers ProMinent ProMinent Fluid Controls

  2. Process Monitors & Controllers • ProMinent DULCOTEST sensors measure the process and the controller displays the value on a large LCD screen • Control outputs can operate various control devices to keep the process within control limits using proportional or PID control action • Alarm relays are available for fault annunciation • Analog outputs are available for recording the measured value • Features/options are selectable by identity code ProMinent Fluid Controls

  3. Mounting Options Ident Code Option W Wall Mount, NEMA 4X Enclosure P Panel Mount, 96 x 96 mm cutout ProMinent Fluid Controls

  4. D1C Measured Variable Options Ident Code Option Range P pH 0-14 R Redox/ORP 0 - 999 mV C Chlorine 0 - 50 ppm L Conductivity 0-20,000 mS/cm Z Ozone 0-2 ppm D Chlorine Dioxide 0-10 ppm T Temperature 32-212 deg. F A Peracetic Acid 0-2000 ppm H Hydrogen Peroxide 0-2000 ppm S Standard Analog Signal 0-20 mA I Chlorite 0-2 ppm ProMinent Fluid Controls

  5. D2C Measured Variables Ident Code Option Range PC Chlorine/pH 0-0.5/2/10/20ppm 0-14 pH PR Redox(ORP)/pH 0 - 999 mV 0-14 pH PP pH/pH 0-14 pH CC Free/Total Cl 0-100 ppm PD pH/Chlorine Dioxide 0-20 ppm ProMinent Fluid Controls