1 / 2

CD-3A Carbon Dioxide Analyzer

<br><br><br>https://aeitechnologies.com/cd-3a-carbon-dioxide-analyzer/<br><br>The CD-3A Carbon Dioxide Analyzer system provides continuous and accurate measurement of carbon dioxide concentrations from 0-15%. The Analyzer consists of a readout/control unit with a connecting cable to the P-61B sensor.<br><br>

Download Presentation

CD-3A Carbon Dioxide Analyzer

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CD-3A Carbon Dioxide Analyzer The CD-3A Carbon Dioxide Analyzer system provides continuous and accurate measurement of carbon dioxide concentrations from 0-15%. The Analyzer consists of a readout/control unit with a connecting cable to the P-61B sensor. Exclusive features:  Wide range of Gas Detection 0 to 15% CO2  Superior accuracy ± 0.02 carbon dioxide  Very high sensitivity ± 0.001% over the entire 0 – 15% CO2 range  Extremely rapid 25 millisecond response – needed for accurate breath-by-breath measurements  End Tidal CO2 Displayed – at the touch of a button  Reliable, low maintenance operation Specifications:  Speed of Response: to 90% of final value in less than 25 milliseconds for a step change in CO2 concentration  Accuracy: ± 0.02% CO2 0 – 7% CO2 range; 1% of the reading >7 – 15% CO2 range  Repeatability: ± 0.01% CO2  Sensitivity: ± 0.001% CO2  Resolution: Digital Display ± 0.01% of CO2  Operating Range: 0 – 15% CO2  Analog Output: 0 to 7.5 Volts buffered for 0 – 15% CO2  Ambient Temperature: 0 – 40°C

  2.  Sample Flow Rate: 10 – 500 ml/min  Display: Continuous display of CO2 concentration or End Tidal CO2 for each breath  Voltage: 120 VAC or 240 VAC Dimensions: Width x Depth x Height in Inches  C-3A CO2 Analyzer Control Unit: 16.5” x 14.5” x 5.7”  C-3A CO2 O2 Analyzer Sensor: 9.0” x 8.6” x 7.0” Weight  C-3A CO2 Analyzer Control Unit: 26 lbs [12 kg]  C-3A CO2 Analyzer Sensor: 9 lbs [4 kg]

More Related