1 / 2

Legend for [SeismoZoom] and PhasePick in ( Array Network Magnitude )

Legend for global options affecting MasterEvent and protocol selection <calt>0 disable <calt>1-9 select <calt> , adjust time pg+ next entry <calt>w write <calt>l list <calt> , adjust ampl pg- last entry. Legend for [EpiMap]

teigra
Download Presentation

Legend for [SeismoZoom] and PhasePick in ( Array Network Magnitude )

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Legend for global options affecting MasterEvent and protocol selection <calt>0 disable <calt>1-9 select <calt>, adjust time pg+ next entry <calt>w write <calt>l list <calt>, adjust ampl pg- last entry Legend for [EpiMap] Cursor above [map] = adjust [EpiZoom]: LMB set upper left corner = position RMB set lower right corner = size Cursor outside [map] or above [scale]: LMB/RMB increase / decrease resolution Arrow keys: ,,, shift [EpiZoom] Character input: p,n patchmap (without stations) on/off c,m [EpiZoom] center to SHYPO/ME z,u zoom/unzoom size of [EpiZoom] l,h list/hide multiple protocol entries Info per Frame f1 Legend f2 Parameter List automovedetection list syncmovelife SonoDet sync protmoveHypoLine protocol bullmoveexternal bulletin NetworkModeArrayModeDWM 3compMagnitudeMode Select Position in Data File, Choose Reference Cursor above [StationButton] = select active trace / phase by marker: LMB/RMB P,Pn or S,Sn onset Cursor above [|SubnetButton|] = LRMB choose subnet Cursor above [DataBox] or [TimeAxis] = LRMB set Start time of [SeismoPlot] NB: length by [b,t,p] and [1,2,4,8] Arrow keys above [DataBox] or [TimeAxis]: , large shift, keep scale, erase onsets <ctrl> , small shift of Start time [SeismoPlot] Character input: 1,2,4,8,b,t,p like[SeismoPlot] Filter SeismoPlot EpiMap Legend for [EpiZoom] & Position of SHYPO Cursor above/out [map] = adjust/erase SHYPO: LMB/RMB take P,Pn or S,Sn as reference Arrow keys: ,,, shift SHYPO <ctrl> , shift depth of SHYPO <ctrl> , shift origin time of SHYPO EpiZoom, P-Beam, Mag-Calif. SeismoZoom Legend for [Filter] Cursor above [bar] / [axis] = set trace / all: LMB/RMB set Lower/Upper frequency Arrow keys (set BP by character input [1-f] first): , shift BP to next lower/upper Character input: .. affecting all traces: 1 [1-2 Hz] 8 [ 8-10 Hz] d [20-24 Hz] 2 [2-4 Hz] a [10-12 Hz] e [24-28 Hz] 4 [4-6 Hz] b [12-16 Hz] f [28-32 Hz] 6 [6-8 Hz] c [16-20 Hz] .. selecting filter bank: nnormalpP-beams S-beam DepthProfile, S-Beam, Magnitude Legend for [P, S-Beam] & Position of SBEAM LRMB above/outside [map] = adjust/erase SBEAM: Arrow keys: ,,, shift SBEAM <ctrl> , shift origin time of SHYPO Character input = select slowness range: t teleseismic[0-0.2 s/km] n near [0-1.5 s/km] r regional [0-0.4 s/km] a acoustic[0-4.0 s/km] l local [0-0.7 s/km] s shallow [0-8.0 s/km] Legend for [SeismoZoom] and PhasePick in (ArrayNetworkMagnitude) Cursor above [seismogram] = set phase or beam window or Max Cursor above [empty left] = erase phase or Max Cursor above [station code] = set marker to: LMB or RMBPc or Sc P/Pn or S/Sn onset 1. or 2. Max L or R-DBCKPg or Lg (if regional) <ctrl>LMB or RMB P or S-beam start <ctrl>L or R-DBCK P or S-beam end Cursor above [calib text] = change gain LMB/RMB increase / decrease Arrow keys: , shift marker to next trace shift Max up/down , shift marked phase one sample <ctrl> , shift marker to next phase Character input: .. affecting all traces: c/f common/fixed scaling on/off u undo last phase pick s sonogram underlay on/off y sync to dt of array n normal-gain plot on/off aautosnap of phases on/off .. affecting active trace, last S-P circle: l/r set to local/regionalp polarity flip .. affecting [EpiMap] and [EpiZoom]: b,g beams,S-P circleson/offh,d hyperbola,S-P circleon/off Legend for [DepthProfile] LRMB above [map] = set depth of hypolines/SHYPO Arrow keys: ,/<ctrl>, shift depth for hypolines/SHYPO <shft> , change max. displayed depth .. only for interactive profiles (half-space/one-layer) , change velocity of half-space/1. layer <ctrl>, change velocity of vS / 2. layer <shft>, change depth of 1. layer Character input: l / 1-n list all / select specific layer model p reset vP/vS to Poisson ratio (toggle) Legend for [SeismoPlot] Cursor above [seismogram] = set window: LMB/RMB set Left/Right of [SeismoZoom] Cursor above [station code] = like <s> Arrow keys: , shift Start time of [SeismoZoom] , decrease/increase [SeismoZoom] Character input: .. affecting parameter choices, i.e., all plots: 1,2,4,8 resample by factor .. affecting sonogram = set seismogram length: b broadband (6.5 octave = 16k samp) t timeres (5.5 octave = 8k samp) p phasepick (4.5 octave = 4k samp) .. overwriting [SeismoZoom]: s Sonogram plot on/off Legend for [Magnitude] Cursor above/outside [map] = set/erase magnitude: LRMB set to default value Arrow keys: , shift dist range {10m.., 100m.., 3km..} , shift magnitude

  2. StationBar Menu-Toolbar Timebar Filter SeismoPlot EpiMap EpiZoom SeismoZoom Depth/Magnitude

More Related