An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MSP3000 Paweł Pilewski Pre-Sales Engineer MICROSENS GmbH & Co. KGPhone: +48 71 337 16 71Email: ppilewski@microsens.pl www.microsens.com • V.2014-10

  2. Table of contents Chassis & Commons 200G Solutions 100G Solutions 8G / 10G /16G Solutions <10G Solutions Amplifiers • EDFA • RAMAN Power Management OADM/ROADM Filters (Mux/Demux) • DWDM • CWDM • Rack Mount Dispersion Compensation Optical Protection Switch

  3. Chassis & Commons

  4. 7HU Chassis • 7RU Shelf(MS430504M) • 311 mm | 12.2 inches (H) • 442 mm | 17.4 inches (W) • 264 mm | 10.4 inches (D) • 11.2 kg | 24.7 lbs • 20 generic PM (Pluggable Modules) slots • Any slot hosts any card • Slot 0 used for management card • Continuously upgradable • No backplane limitations preventing new module deployment—200G today, 400G tomorrow in same chassis

  5. 7HU Chassis - Mechanicals • Two -48V power supplies connectors • 76 W typical without PMs in generic slots • 1000W max with PMs • AC power via external rectifier (orderable through MICROSENS) • One management card (MS430520M-B) • One FAN unit with six fans • One dust filter • One optical fiber guide panel • Operating temperature • 0°C +50°C

  6. 2HU Chassis • 2RU Shelf (MS430501M/MS430503M) • 87 mm | 3.4 inches (H) • 442 mm | 17.4 inches (W) • 240 mm | 9.5 inchess (D) • 6.1 kg | 13.4 lbs • Pluggable 85-265 VAC & -40.8 to -57.6 DC power options • 6 generic PM (Pluggable Modules) slots • Any slot hosts any card • Continuously upgradable • No backplane limitations preventing new module deployment—2x200G today, 2x400G tomorrow in same chassis

  7. 2HU Chassis - Mechanicals • NEBS compliant • One management card (MS430520M-B) • One FAN unit with three fans • Hosts three separate fans, each of which generates a fan failure signal in event no rotation • One dust filter • One optical fiber guide panel • Operating temperature • 0°C +50°C (standard version) • -40°C to +65°C (ETR version) • DC or AC option • 120 W typical without PMs in generic slots • 500W max with PMs • MS430501M input power range • Minimum: -40.8V • Maximum: -57.6V • MS430503M input power range: • Minimum: 85 VAC • Maximum: 265 VAC

  8. 2HU Chassis ETR • 2RU Shelf(MS430501MX) • 87 mm | 3.4 inches (H) • 442 mm | 17.4 inches (W) • 240 mm | 9.5 inchess (D) • 6.1 kg | 13.4 lbs • 6 generic PM (Pluggable Modules) slots • Any slot hosts any card • Continuously upgradable • No backplane limitations preventing new module deployment—200G today, 400G tomorrow in same chassis • Pluggable 85-265 VAC & -40.8 to -57.6 DC power options • -40°C to +65°C operating temperature range • Requires MS430520MX-B

  9. Management Module MS430520M-B • Hosts the SNMP agent • Hosts the embedded web based http craft terminal • Hosts the console port giving access to the CLI • Provides three (3) external Ethernet interfaces through an internal Ethernet switch. • Provides dedicated interfaces to PM slots and FAN slot. • Provides the interface between the SNMP agent and the PM generic slots for managing the equipped PMs and the FAN unit • ETR version is operational from -40°C to +65°C • Compatible with -48V, +24V • Processor: 32 bit, 1.1 GHz • RAM memory: 512 Mbytes • Flash memory: 512 Mbytes • Operating System: Linux

  10. FAN Units • FAN Unit 1 • For 7HU Chassis • 6 fans per module • Hosts two power converters—main & protection • FAN Unit 2 • For 2HU Chassis • 3 fans per module • Hosts one power converter per fan—main only

  11. External Power Supplies • 1RU chassis containing dual power converters from 110/240 VAC to four -48VDC • Two 110/240VAC power inputs • 1 main and 1 protect • Eight -48VDC power outputs • 4 main and 4 protect • Max. power supply • MS430518M: 300W • MS430518MHC: 1000W MS430518M MS430518MHC

  12. 200G Solutions

  13. Flex Rate 200G Muxponder • Provides 400G of throughput capacity • Built-in VOA allows the operator to remotely select the output power level anywhere from +3 dBm to -20 dBm • Software selectable line side modulation —DP-QPSK or 16QAM • Multi-protocol support • Compatible with multiple channel spacings—both on-grid and off-grid • Power consumption : 150W (incl. optics) • Operating Temperature 0°C to +50°C • Availableoption for SFW MS430947M MS430948M • Line Side • Integrated selectable modulation format & line rate • 200G DP-16QAM • 100G DP-QPSK • Proprietary framing • 2xOTU4 into proprietary frame • G.709 & SD FEC • OSNR • 200G: 21 dB —1000 Km • 100G: 11.5 dB—10 000 Km • PMD: 30 ps • Transmit Power: +3 to -20 dBm • Receive Power : • 200G: -9 to -19 dBm • 100G: -5 to -18 dBm • Terminal & facility loopback • Tunable C-band • Client Side • 20 x SFP+ pluggable • 10GbE, 8G/10G FC, OC-192/STM-64 and OTU2/OTU2e protocols • Uses standard patchcord • Terminal & facility loopback

  14. Single slot Flex Rate 200G Muxponder • Optimized version of Flex coherent 200G Muxponder • 1 slot module supporting 100G and 200G line • Software selectable line side modulation —DP-QPSK or 16QAM • Compatible with multiple channel spacings—both on-grid and off-grid • Power consumption : 60W (incl. optics) • Operating Temperature 0°C to +50°C • Dual fiber (MS430943M) and simplexfiber version available (MS430944M) • Airflowcardisneeded in case of 7HU chassis MS430943M • Line Side • Integrated selectable modulation format & line rate • 200G DP-16QAM • 100G DP-QPSK • Proprietary framing • 2xOTU4 into proprietary frame • G.709 & SD FEC • OSNR • 200G: 21 dB —1000 Km • 100G: 12.5 dB—10 000 Km • PMD: 30 ps • Transmit Power: +3 to -25dBm for MS430944M and typ. 0dBm for MS430943M • Receive Power : • -5 to -25 dBm • Terminal & facility loopback • Tunable C-band • Client Side • 2 x QSFP28 pluggable • 100GbE clientor OTU4

  15. 100G Aggregation card • 10x 10G to 100G aggregation module • 10G SFP+ client ports • 100G QSFP28 line port • Line port of MS430945M cascaded on client port of MS430943M module using specific Passive cable • Multiprotocol support on the 10G client side • 8GFC, 10GbE, STM64, OTU2(e), 10GFC, 16GFC • 40G version available in Q3 2018 MS430945M • Line Side • 1x QSFP28 • OTU4 Line interface • Client Side • 10 x SFP+ pluggable • 10G Multirate

  16. 100G Aggregation card - cascading MultiRate (SFP+ clients) Specificopticalpassivecable 2x 100G QSFP28client (100GbE or OTU4): 1 slot solution in 2HU Chassis 1x100G client and 10x10G client (8G/10G/16GFC): 3 slots solution in 2HU Chassis 20x10G client (8G/10G/16GFC): 5 slots solution in 2HU Chassis • 8G, 10G,16G Fibre Channel • 10G Ethernet • 10G SDH / SONET • 10G OTN MS430945M • Single Wavelength • 100G λ or • 200G λ • Single or Dual Fiber MS430943M

  17. 100G Aggregation with Encryption • 1x100GbE or 10x10G to OTU4 rate encrypted Line • GCM-AES-256 encryption (Advanced Encryption Scheme) • ECDH Key exchange mechanism (Diffie-Hellman) • Same 10G multiprotocol configuration as 100G Aggregationcard (MS430945M) • Whole 10x10G multiplex being encrypted all together • 40G version available in Q3 2018 MS430961M • Line Side • 1x QSFP28 • OTU4 Line interface • Encrypted • Client Side • 10 x SFP+ pluggableor QSFP28 • 10G Multirate • 100GBE or OTU4

  18. 100G Aggregation card - cascading MultiRate (SFP+ clients) EncryptedOTU4 2x 100G QSFP28client (100GbE or OTU4): 1 slot solution in 2HU Chassis 1x100G client and 10x10G client (8G/10G/16GFC): 3 slots solution in 2HU Chassis 20x10G client (8G/10G/16GFC): 5 slots solution in 2HU Chassis • 8G, 10G,16G Fibre Channel • 10G Ethernet • 10G SDH / SONET • 10G OTN • 100G MS430961M • Single Wavelength • 100G λ or • 200G λ • Single or Dual Fiber MS430943M

  19. 100G Solutions

  20. 100G OTN Transponder • Line Side • 1 x CFP pluggable • B&W LR4 or coherent WDM • Terminal and facility loopbacks • 100G OTN transponder with 1x100GbE client and OTU4 line side • OTU4 line can be switched through any standards-based OTN mesh network • Assured interoperability in multi-vendor environments — fully G.709 compliant • Economical CFP interfaces for client and line side • 3-slot pluggable module • 2 x 200G modules in MS430501M / 400G in 2RU • 6 x 200G modules in MS430504M / 1.2T in 7RU • Power consumption : 90W (incl. coherent optics) / 75W (incl. LR4 optics) • Operating Temperature 0°C to +50°C MS430913M • Client Side • 1 x CFP pluggable • 100GbE client support • RMON on 100GbE input & output • Terminal & facility loopback

  21. 100G OTN Muxponder • Line Side • 1 x CFP pluggable • B&W LR4 or coherent WDM • Terminal & facility loopbacks • 100G Coherent Metro Access Muxponder w/ 10G aggregation • Data center interconnection & metro transport applications • 3-slot pluggable module • 200G in 2RU • 600G in 7RU • Power consumption : 115W (incl. optics) • Operating Temperature 0°C to +50°C MS430914M • Client Side • 10 x SFP+ pluggable • 10GbE client • RMON on 10GbE input • Terminal & facility loopback

  22. Rack Mount 100G Transponder (MXP100) • 100G Ultra-Long Haul Transponder • Transports 1x100GbE services over 100G coherent tunable optical line • Provides ultra-long haul capability, up to 6000 km • Uses 60% less power than previous version • Pluggable QSFP28 client optics with performance monitoring • Support for up to 88 100G channels • Small form factor, with 100G in 1RU • Alien wavelength capacity upgrade to existing long haul, ultra-long haul and submarine line system • Power consumption : 80W (incl. optics) • Operating Temperature 0°C to +50°C MS430898M • Line Side • Integrated 100G coherent using DP-QPSK modulation • 127.156G nominal line rate • Proprietary framing • OTU4 into proprietary frame • 12.5 dB OSNR—6000 Km • CD Tolerance: ±50,000 ps/nm • PMD: 30 ps • Transmit Power -2 dBm • Receive Power -5 to -15 dBm • Tunable C-band • Client Side • 1 x QSFP28 pluggable • 100GbE client

  23. Rack Mount 100G Muxponder (MXP100) • 100G Ultra-Long Haul Muxponder • Transports 10x10G multiprotocol services over 100G coherent tunable optical line • Provides ultra-long haul capability, up to 6000 km • Uses 45% less power than previous version • Pluggable SFP+ client optics with performance monitoring • Support for up to 88 100G channels • Small form factor, with 100G in 1RU • High density 8G/10G service aggregation • Fiber relief for congested routes • Alien wavelength capacity upgrade to existing long haul, ultra-long haul and submarine line system • Power consumption : 110W (incl. optics) • Operating Temperature 0°C to +50°C MS430899M • Line Side • Integrated 100G coherent using DP-QPSK modulation • 127.156G nominal line rate • Proprietary framing • OTU4 into proprietary frame • 12.5 dB OSNR—6000 Km • CD Tolerance: ±50,000 ps/nm • PMD: 30 ps • Transmit Power -2 dBm • Receive Power -5 to -15 dBm • Tunable C-band • Client Side • 10 x SFP+ pluggable • 8G FC, 10GbE, OC-192; STM-64; OTU2; OTU2e clients

  24. 8G/10G/16G Solutions

  25. Long Haul 10G Transponder • Metro, Regional and Long Haul transport, backhaul and business services applications • ETR variant for use in outdoor enclosures • Single slot 10G Transponder • ETR variant is dual slot • Link distances up to 300 km without in-line amplifiers and with full channel counts • Distances of more than 2000 km for multi-span • Power consumption : 27W (incl. optics) • Operating Temperature 0°C to +50°C • ETR variant: -40°C to +65°C MS430567MTX • Line Side • Single XFP line port • 12 dB OSNR • 10 dB FEC • 40 Km /80 Km 1550 nm DWDM • 80 Km Tunable @ 100GHz • FFI (ETR variant only) • 10 dB FEC • 80 Km Tunable @ 50GHz • Proprietary line format • 11.09G nominal line rate • Loopback • Client Side • 1 x SFP+ pluggable • 10GbE LAN/WAN, OC-192/STM-64 clients • RMON on 10GbE input • Loopback

  26. 10G Protocol Converter • Two slot 10G module • Converts 10G LAN PHY to 10G WAN PHY for transport over existing SONET/SDH networks • Rate adaptation done by removing IDLE frames • Eliminates the need for expensive router interfaces • 10G LAN monitoring on ingress and egress • Bits, bytes, frames, dropped frames, pause frames • Flow control mechanism can generate MAC pause frames to source device or drop frames if LAN rate exceeds WAN rate • 24 km max distance from source device • Power consumption : 24W (incl. optics) • Operating Temperature 0°C to +50°C MS430572M • Line Side • Single XFP line port • 12 dB OSNR • 40Km/80 Km 1550 nm DWDM • 80 Km Tunable @ 100GHz • Proprietary line format • 11.09G nominal line rate • Loopback • Client Side • 1 x XFP pluggable • 10GbE LAN client • RMON on 10GbE input • Client / XFI loopback

  27. Dual 10G Transponder • Two-slot 2 x 10G Transponder, 1 x 10G Transponder with protection or 10G Regen • Metro, Regional and Long Haul transport, backhaul and business services applications • Performs full 3R (Retime, Reshape and Retransmit) signal regeneration • Link distances up to 300 km without in-line amplifiers and with full channel counts • Distances of more than 2000 km for multi-span • Power consumption : 66W (incl. optics) • Operating Temperature 0°C to +50°C MS430569M • Line Side • Dual XFP line ports • 12 dB OSNR • 10 dB FEC • 40 Km /80 Km 1550nm DWDM • 80 Km Tunable @ 100GHz • Proprietary line format • 11.09G nominal line rate • Loopback • Client Side • 2 x SFP+ pluggable • 10GbE LAN, OC-192/STM-64 clients • RMON on 10GbE input • Loopback

  28. Video Muxponder • Three-slot module aggregates up to 4 video streams on a single 10G wavelength • Any combination of SDI, HD-SDI-PAL, HD-SDI-NTSC signals • Each port auto-senses signal type upon commissioning • Combine video with 1xFE + 1xGbE • Supports 6 video ports if FE & GbE not used • Variants with encryption and drop-and-continue (for broadcast) • Power consumption : 35W (incl. optics) • Operating Temperature 0°C to +50°C MS430654MV • Line Side • Dual XFP-based line ports • 21 dB OSNR • 40/80 Km 1550 nm DWDM • 80 Km Tunable @ 100GHz • Proprietary line format • 11.09G line rate • Loopback • Client Side • Coaxial BNC interfaces for SDI ports • Standard RJ45 port for FE • SFP for GbE • Loopback

  29. Multiprotocol Muxponder • Two-slot module aggregates up to eight (8) client services on a single 10G wavelength • Any combination of 1G FC, 2G FC, 4GFC, OC-48/STM-16, OC-12/STM-4 and GbE signals • Any service, any port • Ideal for Business Services, DCI/Disaster Recovery, Triple or Quadruple Play, Wireless Backhaul, IP DLC/DSLAM Backhaul • LH module w/ DynaFEC (10dB gain) & 12 dBOSNR • Optional 1+1 ine protection w/ 50ms switching • Power consumption : • XFP: 38W (incl. optics) • Operating Temperature 0°C to +50°C MS430687M • Line Side • Single or dual XFP line ports • 12 dB OSNR • 10 dB FEC • 40 Km /80 Km 1550nm DWDM • 80 Km Tunable @ 100GHz • Proprietary line format • 11.09G nominal line rate • Loopback • Client Side • 8 x SFP for GbE • Client/XFI loopback

  30. Multiprotocol Muxponder with ADM • Two-slot module aggregates up to eight (8) client services on a single 10G wavelength • Any combination of 1G FC, 2G FC, 4GFC, OC-48/STM-16, OC-12/STM-4 and GbE signals • Any service, any port • Ideal for Business Services, DCI/Disaster Recovery, Triple or Quadruple Play, Wireless Backhaul, IP DLC/DSLAM Backhaul • Metro module w/ 6.5 dB FEC gain & Add/Drop Multiplexing (ADM) capability • Optional 1+1 line protection w/ 50ms switching • Power consumption : • XFP line: 38W (incl. optics) • Operating Temperature 0°C to +50°C MS430686MDC • Line Side • Single or dual XFP line ports • 17 dB OSNR • 6.5 dB FEC • 40 Km /80 Km 1550nm DWDM • 80 Km Tunable @ 100GHz • Proprietary line format • 11.09G nominal line rate • Loopback • Client Side • 8 x SFP • Ring SNCP type protection on individual client protocol • Client/XFI loopback

  31. 10G Transponder • Single slot 10G regenerator module • Long Haul transport and backhaul applications • Performs full 3R (Retime, Reshape and Retransmit) signal regeneration • Link distances up to 300 km without in-line amplifiers and with full channel counts • Distances of more than 2000 km for multi-span • Power consumption : 10W (incl. optics) • Operating Temperature 0°C to +50°C MS430550M • Line Side • Single XFP line port • 21 dB OSNR • 40 Km /80 Km 1550nm DWDM • 80 Km Tunable @ 100GHz • Proprietary line format • 11.09G nominal line rate • Loopback • Client Side • 1 x XFP 40, 80 kmsB&W or DWDM • Any 10G from 9.95 Gbps to 11.09 Gbps • 10GbE LAN/WAN, OC-192/STM-64, OTU2, 10GFC • Client/XFIIoopback

  32. 10G OTN Transponder • Dual slot 6 x 10G OTN transponder • Full G.709 standards compliance • Provides low cost connection to/from switched OTN core network • 10-20µs latency • Power consumption : 30W (incl. optics) • Operating Temperature 0°C to +50°C MS430553M • Client Side • 6 x SFP+ • 10GbE; OC-192/STM-64 client interfaces • Terminal & Facility Ioopbacks • Line Side • 6 x SFP+ • G.709 OTU2/OTU2e line rate—11.096 Gbps • 17 dB OSNR • Terminal & Facility Ioopbacks

  33. Quadrupler 16G Transponder • Four independent transponders on one single-slot blade • Supports 8G/10G/16G Fibre Channel and 10 Gigabit Ethernet • Up to 80 x 16G channels in a single chassis • Full 3R regeneration • Low latency • Power consumption : 15W (incl. optics) • Operating Temperature 0°C to +50°C MS430558M • Target Applications • Enterprise connectivity • Server and storage replication/virtualization • Business continuance and disaster recovery • (BC/DR) • Campus networking • Managed business services • Line Side • 4 x SFP+ • 8G/10G • 23 dB OSNR • 80Km Tubnable @ 100GHz • 16G • 25 dB OSNR • 40 Km 1550nm DWDM • Client Side • 4 x SFP+ • 8G/10G/16G FC & 10GbE • Client/XFIIoopback

  34. CPRI Muxponder • Two slot module • Dual 4X 2.5G CPRI + 1 GbE over dual 10 G uplinks • Aggregate up to 9x CPRI or 8x CPRI and 2x Sync-E • Extended Temperature Range (ETR) compatible • Can be deployed in outdoor cabinet at cell site • Low latency—2 μs • Power consumption : 30W (incl. optics) • Operating Temperature 0°C to +50°C • ETR variant: -40°C to +65°C MS430671M • Target Applications • Mobile Front Haul • Client Side • 10 x SFP+ • 8 x CPRI Option 3 (2.5G) • 2 x Synchronous Ethernet (GbE) • RMON on GbE input • Line Side • 2 x SFP+ • Proprietary line format • 11.06G

  35. <10G Solutions

  36. STM1 Muxponder • Single slot module • 4 x OC-3/STM-1 client port interfaces or 1 x OC-12/STM-4 client port interface • Fully transparent transport of OC-3/STM-1 or OC-12/STM-4 client signals • 1.25Gbps line interface compatible with otherMuxponders client interface for further aggregation over higher speed links • Power consumption : 12W / 14W (incl. optics) • Operating Temperature 0°C to +50°C MS430614M • Target Applications • Business Services • Low speed aggregation • DSLAM backhaul • Client Side • 4 x SFP • 4 x OC-3 / STM-1 • 1 x OC-12 / STM-4 • Line Side • 1 x SFP, CWDM / DWDM • 1.25G

  37. Two port GBE Muxponder • Single slot module • Dual mode • Aggregation of two GbE/GFC over OC-48/STM-16 • OC-48/STM-16 transport with 1+1 protection • Fully compatible with SONET/SDH equipment • Power consumption : 16W (incl. optics) • Operating Temperature 0°C to +50°C MS430605M • Target Applications • Ethernet services over SONET/SDH network • Protected OC-48 or STM-16 services • DSLAM backhauling • Line Side • 2 x SFP, CWDM / DWDM • OC-48 / STM-16 • Optional 1+1 line protection with APS feature • Client Side • 2 x SFP • 2 x GbE or 1G FC • 2 x OC-48 / STM-16 • RMON on GbE input

  38. Quadruple Transponder • Single slot quad transponder • CWDM and DWDM transponder or repeater • Supports any protocol from 100M to 4G • Software selectable data rates • Full 3R signal regeneration • Power consumption : 13W (incl. optics) • Operating Temperature 0°C to +50°C MS430584M • Target Applications • CWDM & DWDM networks • Edge, Metro and Regional optical networks • SONET/ SDH, Ethernet and Storage networks • Regeneration sites • Wavelength conversion • Client Side • 4 x SFP • FastE, GbE, OC-3/12/48, STM-1/4/16, 1/2/4G Fibre Channel • RMON on GbE input • Line Side • 4 x SFP • CWDM / DWDM

  39. AmplifierUnits

  40. LC Booster/Preamplifier • EDFA-based Optical Booster and Preamplifier (OABP) • Cost-efficient amplification solution for metro and regional applications • Operates in constant output power mode • Can be tuned to reach a required output power MS430866M • Size: Two slots • Power consumption: 4W • Connector: dual LC

  41. LC In-Line Amplifier • EDFA-based In-Line amplifier (OAIL) • Cost-efficient amplification solution for metro and regional applications • Operates in constant output power mode • Can be tuned to reach a required output power MS430865M • Size: two slots • Power consumption: 4W • Connector: dual LC

  42. HC Booster/Preamplifier • EDFA-based Optical Booster and Preamplifier (OABP) • High capacity amplification solution for metro and regional applications • Configurable for constant output power or constant gain modes • Output power is upgradable in-service in the field using pump module (see following slide) • Optical Supervisory Channel insertion and extraction for remote management (requires separate OSC card. See following slide) • Automatic Power Reduction (APR) mechanism • Shuts down output EDFA gain block when a loss of signal is detected on the input of an EDFA gain block to prevent any light emission in the broken fiber MS430845M • Size: Two slots • Power consumption: 12W • Connector: dual LC

  43. HC In-Line Amplifier • High capacity amplification solution for metro and regional applications • Configurable to operate in constant output power or constant gain modes • Output power is upgradable in-service in the field using pump module (see following slide) • Bi-directional operation • Dual Optical Supervisory Channel insertion and extraction for remote management (requires separate OSC card) • Mid-stage access for Chromatic Dispersion devices • Automatic Power Reduction (APR) mechanism • Shuts down output EDFA gain block when a loss of signal is detected on the input of an EDFA gain block to prevent any light emission in the broken fiber • Extended Temperature Range (ETR) version is designed for operating in outside cabinets or unconditioned spaces • Ambient temperature range of -40°C to +65°C MS430846MX • Size: two slots • Power consumption: 12W • Connector: dual LC

  44. HCS-17 Variable Gain Amplifiers • EDFA-based Optical Booster / Preamplifier (OABP), or bi-directional Optical In-line Amplifier (OAIL) variants • Integrated 1510 nm Optical Supervisory Channel (OSC) insertion and extraction—no external OSC required • Automatic fiber aging compensation • Automatic adjustment of optical power as channels are added and removed • Configurable for constant output power or constant gain modes • Mid-stage access for Chromatic Dispersion devices (OAIL) MS430849M-17 MS430848M-17 • Size: two slots • Power consumption • OABP: 5W • OAIL: 6W • Connector: dual LC

  45. HCS-20 Variable Gain Amplifiers • EDFA-based Optical Booster / Preamplifier (OABP), or bi-directional Optical In-line Amplifier (OAIL) variants • Integrated 1510 nm Optical Supervisory Channel (OSC) insertion and extraction—no external OSC required • Automatic fiber aging compensation • Automatic adjustment of optical power as channels are added and removed • Configurable for constant output power or constant gain modes • Mid-stage access for Chromatic Dispersion devices (OAIL) MS430849M-20 MS430848M-20 • Size: two slots • Power consumption • OABP: 5W • OAIL: 6W • Connector: dual LC

  46. Optical Pump • External optical pump providing 3 dBm optical output power for EDFA HC • Increases optical output power (Pout) to each amplifier (Booster, Pre-Amp and In-Line) to +20dBm (with one external pump) or +23dBm (with two external pumps) • Uses two individual laser pumps—one for each direction of the amplifier MS430847M • Size: one slot

  47. Optical Supervisory Channel • The OSC provides a dedicated communications channel used for the remote management • Three port Ethernet switch: • One electrical port on the backplane connector to connect to MNGT card • Two optical port through SFP on the front panel • Alarms provided: • OSC 1 and OSC 2 Loss of incoming Signal • OSC 1 and OSC 2 Laser Shutdown • Measures provided: • SFP temperature in °C • SFP voltage in V • SFP receive power in dBm • SFP transmit power in dBm • SFP laser pump current (bias) in mA • DDM (Digital Diagnostic Monitoring) information from SFP MS430890M • Size: one slot • Power consumption: 7W • Connector: SFP

  48. Raman Amplifier • Designed for long single-span links and elimination of intermediate amplifier sites (hut skipping) • Works with 10G, 100G and 200G line rates • Provides OSNR improvement compared to EDFA only • Contra-directional and co-directional operation • Can be used on its own or with EDFAs • Comprehensive eye safety - Class 1M • Automatic shutdown and restart • Alerts for fiber link degradation and/or gain reduction MS430852M • Size: one slot • Power consumption: 35W • Connector: • E2000 HP (amplified output signal) • LC (input signal)

  49. ROPA System • Allows for ultra-long spans up to 450km* with no in-line active components • All active components in the system are located at the terminal site of a WDM span, even when inline amplification is necessary • Supports both single-channel and WDM links over typical usable spectrum of 1547nm to 1560nm • Consists of two components • MS430835M(Remote Amplifier Pump): Remotely pumps the ROA in the fiber amplifying the WDM channels that pass through it • MS430837M(Remote Optical Amplifier): Spliced into the fiber within 80km of the location of the RAP. Can be mounted vertically or horizontally • MS430835M has three pump laser diodes at wavelengths 1424 nm and 1452 nm and features multiple independent laser safety features based on Automatic Power Reduction (APR) • MS430837M is purely passive and can be housed in an independent splice box or can be installed in an existing splice box on the route MS430835M • Size: 1RU • Line Connector: • CE2000 High Power Connector MS430837M *Based on 10G wavelengths

  50. Power Management Modules