An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Remount & Occlusion Correction

  2. Causes of Denture Errors • Clinical errors • Technical errors • Inherent deficiencies in the material itself

  3. Evaluation Procedures • Processing • Polished surfaces • Tissue fit and comfort • Retention, stability and support • Jaw relations • Occlusion • Esthetics • Speech

  4. Evaluation of Processing * • Inspect for processing errors, e.g. porosity • Inspect for inadequate polishing • Run your finger along the borders & impression surface to check if sharp edges or acrylic spicules exist • Examine frenal notches for sharp edges • Examine for adhered plaster or stone fragments

  5. Patient Education & Preparation * • First oral feeling with fullness is normal & will disappear over time • Excessive salivation (compulsive spitting or rinsing should be avoided,instead swallowing encouraged to remove excess saliva)

  6. Evaluation of Tissue Fit & Comfort Pressure Indicating Paste (PIP)* • Every new denture must be checked with PIP to identify and determine if pressure areas exist to reduce them.

  7. Evaluation of Tissue Fit & Comfort • Never adjust unless you can see exactly where to adjust • Use indicator medium • (PIP, indelible marker, etc)

  8. Place Paste with Streaks

  9. How to Read PIP? • Streaks - no contact (N) • No Paste - Impingement (I) • Paste, no streaks - normal contact (C)

  10. Evaluation of Tissue Fit & Comfort Severe undercuts • Cause abrasion and soreness in seating and removal • Management Relieve with extreme caution with aid of PIP

  11. Evaluation of Tissue Fit & Comfort Overextended borders • Denture appears to rise or has inadequate retention • Management Identify the offending borders, mark with indelible marker inside the mouth and carefully reduce

  12. Evaluation of Retention, Stability & Support • Test for retention* • Test for posterior palatal seal

  13. Test for Rocking • Apply alternating finger pressure on occlusal surfaces of R & L sides • Rocking around fulcrum point • Midpalatalraphe is a common fulcrum point if inadequate relief has been provided *

  14. Evaluation of Occlusion • Denture processing almost always causes changes in occlusion due to dimensional changes in resin • These changes are usually manifested as increase in OVD

  15. Causes of Occlusal Errors • Errors in impressions • Ill-fitting trial denture bases • Inaccurate jaw relation records • Errors during transfer of the records to articulator • Incorrect arrangement of posterior teeth • Dimensional changes during curing • Processing faults……..*

  16. processing errors: 1.Dimensional changes in the wax after setting up of the teeth. This should be very slight if the occlusion of the wax-up was carefully examined before flasking. 2.The heat cured acrylic resin expands and contracts during the curing procedure. It expands as the polymerizing temperature is reached then starts to contract (polymerization shrinkage) .Then as it cools to room temperature it contracts again. The total effect of this dimensional change is a slight shrinkage which may change the position of the teeth. 3.The expansion of the investing material during the processing. 4.The pressure of the flask press.

  17. Why is it difficult to detect occlusal errors in the mouth? * Negative attitude (assume an error exists and try to find it)

  18. What is the ideal occlusal contact? At first contact, even maximum intercuspation at CR without denture shifting or instability & without pain *

  19. Types of Occlusal Errors • CO not coincide with CR • Premature contact (high point) in one or both sides • Uneven distribution of occlusal contacts • Eccentric movement prematurities (protrusive & lateral)

  20. What are the Methods of Detecting Occlusal Errors? • Touch & slide method • Denture dislodges or shifts when patient occludes • Pt complains of pain beneath denture bases

  21. Correction of Occlusal Errors • Laboratory remounting • Clinical remounting • Direct intraoral correction

  22. Laboratory Remounting * Disadvantages Cannot correct errors made while recording jaw relations Cannot correct errors made while mounting the casts on the articulator Does not compensate changes caused by settling of the denture bases

  23. *In order to correct these errors, the dentures are returned to the articulator after deflasking.The casts are repositioned on the original plaster mountings using the key (index) in the base of the cast. The casts are attached to the plaster mountings by sticky wax. *The condylar elements of the articulator are locked in the centric relation and the articulator is closed. If the incisal pin does not touch the incisal guide table the occlusal vertical dimension has been changed and must be re-established.

  24. Lab remounting • Selective grinding is carried out using articulating paper to mark the area of premature contacts and reduced with small stones The sequence of steps should be as follows: 1. Restore the vertical dimension. 2. Refine centric occlusion. 3. Perfect working and balancing occlusion. 4. Correct protrusive occlusion

  25. Carborundumpaste milling: The articulator is moved through all the excursive movements using carborundum paste to smooth the various gliding surface of the teeth. Milling must be done lightly to prevent losing balancing contacts which might decrease the vertical dimension. a. Move the articulator into right lateral, left lateral and protrusive movements. b. Move the articulator in a circular movement. Use light strokes do not force or press.

  26. Clinical Remounting with New Interocclusal Records * Advantages • Correct errors made during recording of jaw relations, or while mounting cast on articulator • Less chair side time • Corrections away from the patient’s view • No saliva which makes detection by articulating paper difficult • No shifting of dentures or incorrect closure by patient

  27. The Aim of Clinical Remounting The prematurities are ground until multiple, uniformly distributed and even contacts are obtained bilaterally

  28. Clinical remounting is currently the most commonly preferred method of occlusal correction

  29. Clinical Remounting Procedure • Ask patient to bite on cotton rolls for 10 min. • Guide mandible into CR several times. • Bite registration material is placed on the post. teeth of the mandibular denture

  30. Clinical Remounting Procedure • Guide mandible into CR • Obtain interocclusal record of CR.

  31. Clinical Remounting Procedure • Mount upper denture using remounting jig • Mount lower denture

  32. Clinical Remounting Procedure

  33. Selective Spot Grinding * The art of reducing premature contacting surfaces, so that an equal pressure exists at all points with interference at no point.

  34. How to Recognize Premature Contacts? • A dark ring with a light center usually denotes a premature contact • You should distinguish betw. marks made by normal occlusal contacts and those of premature contacts • Articulating paper should not be reused many times and should be changed often.

  35. Selective Spot Grinding Make grinding until even (same intensity), stable, and multiple marks spread over wide area in both sides

  36. Eliminating Occlusal Errors • Re-establishment of CO. • Correction of protrusive relation. • Correction of working side occlusal errors. • Correction of balancing side errors. Initially, centric occlusion errors are corrected, followed by protrusive, R & L lateral interferences.

  37. Basic Tooth Positions Balancing Contacts Centric Occlusion Working Contacts

  38. Selective Grinding Rules to Obtain CO • After the first few taps on the articulating paper only a few high contacts appear. • The marking process and the grinding are repeated until all except the anterior teeth contact in CO. • Ideally all holding cusps * of the maxillary and mandibular posterior teeth will make simultaneous contacts. • It is not uncommon for one or two functional cusps not to make contact after establishing the final CO. • It is not necessary to continue adjusting until these cusps make contacts because aggressive adjustment will sacrifice the established OVD

  39. Selective Grinding Rules to Obtain CO • As far as possible, avoid grinding cusp tips especially centric holding cusps, instead grind the opposing fossae or marginal ridges where the centric holding cusps occlude • If the high contact is on the centric holding cusp inclines, the cuspal inclines can be reduced, thereby gradually moving the contact more toward the bearing cusp tip. • A centric holding cusp may be reduced when it interferes with another centric holding cusp or when makes interferences in centric and eccentric positions

  40. Re-establishment of CO Problem: Teeth too long Solution: Deepen the fossae

  41. Re-establishment of CO Problem: Teeth too nearly end to end Solution: Grind Inclines

  42. Re-establishment of CO Problem: Too much horizontal overlap Solution: Broaden central fossae

  43. After the CO re-establishment…. • DO NOT: • Reduce maxillary lingual cusps. • Reduce mandibular buccal cusps. • Deepen the fossae.

  44. Correction of Protrusive Relation • The teeth are brought edge to edge • Any interferences to smooth anterior gliding of dentures are eliminated by grinding • Elimination of protrusive interferences along a path of 3 to 5 mm is sufficient

  45. Correction of Working Side Occlusal Errors BULL rule buccal upper-lingual lower

  46. Correction of Working Side Occlusal Errors • Reduce lingual inclines of buccal cusps of upper teeth. • Reduce buccal inclines of lingual cusps of lower teeth. ON WORKING SIDE ONLY!!!

  47. Correction of Working Side Occlusal Errors Problem: Buccal and lingual cusps too long. Solution: Change inclines of balancing cusps.

  48. Correction of Working Side Occlusal Errors Problem: Buccal cusps are too long Solution: Change lingual incline of maxillary buccal cusp

  49. Correction of Working Side Occlusal Errors Problem: Lingual cusp too long. Solution: Change buccal incline of lingual cusp of mandibular tooth.