1 / 24

Applications of cw and pulsed lasers for in-vivo skin diagnostics: some recent results

Applications of cw and pulsed lasers for in-vivo skin diagnostics: some recent results. Janis Spigulis, Vanesa Lukinsone, Martins Osis and Ilze Oshina. SFM-2018, 24/09/2018. Biophotonics lab in Riga: our profile.

tbridges
Download Presentation

Applications of cw and pulsed lasers for in-vivo skin diagnostics: some recent results

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Applications of cw and pulsed lasers for in-vivo skin diagnostics: some recent results Janis Spigulis, Vanesa Lukinsone, Martins Osis and Ilze Oshina SFM-2018, 24/09/2018

  2. Biophotonics lab in Riga: our profile Aim – to develop affordable for end-users methods, devices and technologies for clinical diagnostics and monitoring, by exploiting optical features of in-vivo skin: - Skin autofluorescence (AF): • photo-bleaching (AFPB) effects, skin “photo-memory” • parametric AFPB rate imaging  diagnostic potential studies • Skin diffuse reflectance spectroscopy (DRS): • fibre-optic contact probe DRS, • multi-spectral imaging skin chromophore mapping potential for distant skin assessment • Skin blood pulsations (photoplethysmography, PPG) • bilateral, multi-site and multi-spectral PPG • distant(wireless and non-contact) PPG clinical applications

  3. Skinmalformations BENIGN MALIGNANT Melanoma Nevi Basal cell carcinoma Seborrheic keratosis Squamous cell carcinoma Hemangioma

  4. Motivation for better skin assessment • Clinical need for a non-invasive, patient-friendly and informative devices for skin diagnostics; • Drawbacks of currently available devices: • Low sensitivity; • Insufficient reliability; • Bulky design, cable/PC; • Mainly use skin color images parametric images are helpful(e.g. chromophore maps, specific index-maps); • Expensive. Siascope DermaLite MelaFind

  5. Seborrheic keratosis (SK): AF signature! Every 4th misdiagnosed melanoma appeared to be SK. cw 405nm LED excitation  smartphone camera G-band AF intensity images for a number of skin malformations AF intensity of SK - always higher than that of healthy skin; nevi, BCC and MM - lower A.Lihachev et al., “Differentiation of seborrheic keratosis from basal cell carcinoma, nevi and melanoma by RGB autofluorescence imaging”, Biomed.Opt.Expr., 9(4), 1852-1858 (2018).

  6. AF kinetics studies: ps measurement setup

  7. Skin AF under 405nm laser excitation: 3 lifetime components,photobleaching effect I.Ferulova, A.Lihachev, J.Spigulis, “Photobleaching effects on in-vivo skin autofluorescence lifetime”, J.Biomed.Opt., 20(5), 051031 (2015).

  8. Skin AF lifetime images: photobleaching effects V.Lukinsone, “In-vivo skin autofluorescence kinetics at continuous and pulsed laser excitation”, PhD Theses, Riga, 2017.

  9. Problem: skin-remitted photon path length.Monte-Carlo simulations (A.Bykov) I(x) I(x) Diffuse reflectance absorption: I Slab absorption, I(x) = I exp(-kx) x x  f(x) ! J.Spigulis, I.Oshina, A.Berzina, A.Bykov, “Smartphone snapshot mapping of skin chromophores under triple-wavelength laser illumination”, J.Biomed.Opt., 22(9), 091508 (2017).

  10. Can it be measured directly?

  11. Setup for skin diffuse reflectance kinetics Differences from the fluorescence setup – the same (input) wavelengths detected; «white» ps laser used, spectral bands selected by a set of interference filters; special fibre holder designed

  12. Skin input and remitted pulse shapes, 650 nm Left forearm of a single volunteer

  13. Input-output pulse peak delay Left forearms of 8 volunteers, averaged values

  14. Output-input pulse half-width difference Left forearms of 8 volunteers, averaged values

  15. Pulse peak delays: spectral dependence Left forearms of 8 volunteers, averaged values

  16. Differences of pulse half-widths: spectral dependences Left forearms of 8 volunteers, averaged values; «jump» around 600nm observed only at 8 mm Inter-fibre distance, unsufficient S/N at longer distances for 550nm and 600nm

  17. Calculated pathlength of the “first” skin-remitted photons as a function of wavelength at inter-fibre distance 8mm (n=1.36, single volunteer) s = t . c/n

  18. Multi-monochromatic spectral imaging • We can extract 3 monochromatic spectral images from a single-snapshot RGB image data, if object (skin) is illuminated simultaneously by 3 laser lines and the RGB-band sensitivities of the image sensor are known • Next step – conversion of 3 monochromatic spectral images into distribution maps of 3 main skin chromophores

  19. Smartphone add-on triple wavelength laser illuminator: 450nm, 532nm, 659nm Method and device for smartphone mapping of tissue compounds. WO 2017/012675 A1, 2017.

  20. RGB image (a) and maps of chromophore content changes for 3vascular hemangiomas:b – oxy-hemoglobin, c – deoxy-hemoglobin, d – melanin Spigulis J., et al. Smartphone snapshot mapping of skin chromophores under triple-wavelength laser illumination. J.Biomed.Opt., 2017, 22(9): 091508.

  21. Underdevelopment • Double-snapshot RGB imaging technique, each snapshot under different 3l-combined illumination enables mapping up to 6 skin chromophores (patented) • Qualityimprovementofthemonochromaticspectralimagesbylaserspeckleremoval(patented) • First switchable4l and 5l laserilluminatorprototypescreated • Monochromatic spectral imaging for counterfeit detection (forensics) LV 15106 B (2016). Method and device for mapping of chromophores under illumination by several laser lines (J.Spigulis. I.Oshina).

  22. Smartphone forensics:Spectral line ratio images (A – authentic, C – counterfeit) A C 448/532nm 659/448nm RGB

  23. SUMMARY • Two biophotonic technologies for improved in-vivo diagnostics of skin malformations have been proposed, experimentally studied and validated in clinical measurements: • Kinetic analysis of skin AF lifetimes and diffuse reflectance under ps-laser pulsed irradiation; • Snapshot mapping of the main skin chromophores under triple-wavelength laser illumination. • Clinical measurements  promising potential for future implementation in clinical praxis • We are open for further international collaboration

  24. Thank You! janispi@latnet.lv www.lanet.lv/~spigulis

More Related