1 / 20

Mihael Makek for the PHENIX Collaboration

Measurement of low mass dielectrons in Au+Au collisions with the HBD upgrade of the PHENIX detector. Mihael Makek for the PHENIX Collaboration. QM2011, Annecy. Outline:. Low mass dileptons The HBD Performance in RHIC Run-9 and Run-10 Status of the dielectron analysis in Au+Au

tarai
Download Presentation

Mihael Makek for the PHENIX Collaboration

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Measurement of low mass dielectrons in Au+Au collisions with the HBD upgrade of the PHENIX detector Mihael Makek for the PHENIX Collaboration QM2011, Annecy

  2. Outline: • Low mass dileptons • The HBD Performance in RHIC Run-9 and Run-10 • Status of the dielectron analysis in Au+Au • Conclusion and outlook M.Makek, QM2011

  3. Low mass dileptons • Dileptons interact only electromagnetically, their path from the interaction region to the detectors almost undisturbed • Probes for chiral symmetry restoration and in-medium modification of the low mass vector mesons • Results* from RHIC Run-4: Yield in mee = 0.15 - 0.75 GeV/c2 larger by a factor 4.7 +/- 0.4(stat.) +/- 1.5(syst.) +/- 0.9(model) compared to the expected hadronic contribution • S/B in this mass region is 1/200 • combinatorial background should be reduced! *Phys.Rev.C81, 034911 (2010) M. Makek, QM2011

  4. Low mass dileptons How to reduce the combinatorial background? • The main sources of the combinatorinal background in PHENIX originate from: π0     e+ e- π0  e+ e- • Distinguish e+e-from π0Dalitz decays and conversions by the opening angle Simulation f->e+e- p0->e+e-g comb. backg. pair qop • Preserve the opening angle by creating a magnetic field-free region • Install a detector which can distinguish single electron hits from open pairs and double electron hits from close pairs •  the goal of the Hadron Blind Detector! M. Makek, QM2011

  5. HBD – the basic concept qpair opening angle Cherenkov blobs e- e+ B≈0 • The HBD is a Cherenkov detector • Proximity focus configuration no window, no mirror • CF4 radiator and active gas. Lrad=50 cm • Very large bandwidth 108 – 200 nm (6.2 - 11.5 eV) • triple GEMs for signal multiplication • CsI photocathode • hexagonal pad readout (pad side 1.55 cm) • total radiation length within acceptance: 2.4% 0.65 m 1.21 m NIMA (2011) doi:10.1016/j.nima.2011.04.015 M. Makek, QM2011

  6. HBD – hadron blindness • Electron signals are relatively rare (compared to hadrons) mesh primary ionization from dE/dx photo electron 140 μm El. Field CsI (350 nm) 70 μm F. Sauli ,NIM A 386 (1997) 531 GEMs pads Detector operated in reverse bias mode to repel the ionization charge from dE/dx Cherenkov light is formed only by e+ or e- M. Makek, QM2011

  7. HBD performance:single vs. double hit recognition HBD charge single hit Close pair Open pair • Single electron charge peaks at 20 pe • Double electron charge peaks at ~40 pe • Good single to double separation • Plot data from fully reconstructed 0Dalitz pairs (m < 150 MeV/c2) in the central arms. Matched to HBD into two separate clusters (open pairs) or one single cluster (close pairs). HBD charge double hit Run 9, p+p M. Makek, QM2011

  8. HBD performance:figure of merit N0 and single electron detection efficiency • The average number of photo-electrons Npe in a Cherenkov counter: with: • bandwidth: 6.2 eV (CsI photo-cathode threshold) - 11.5 eV (CF4 cut-off) Quantum efficiency kept constant during the two years of operation! The highest ever measured N0! The high photoelectron yield excellent single electron detection efficiency:  Single electron efficiency using a sample of open Dalitz decays:  ~ 90 % Single electron efficiency derived from the J/Y region:  = 90.6  9.9 % M. Makek, QM2011

  9. Background rejection in p+p Pairs in Central Arms Present status from Run-9 p+p: Background reduction in mee > 0.15 GeV/c2 (not fully optimized) Pairs matched to HBD Pairs after HBD reject. Run 9, p+p M. Makek, QM2011

  10. HBD analysis in Au+Au • Challenge in Au+Au measurement: • Large multiplicity -> scintillation from CF4 -> Large detector occupancy -> Statistical fluctuations of the underlying event charge But there are solutions! • Analysis steps: • Subtract the underlying event • Reject the electrons created downstream of the HBD • Reject the p0 Dalitz and the conversions created upstream M. Makek, QM2011

  11. HBD analysis in Au+Au:subtraction of the underlying event • Two approaches for underlying event subtraction (event-by-event): • local charge subtraction • average module charge subtraction -> consistent results • Occupancy reduced to ~15% in MinBias • After subtracting the underlying event, the remaining fluctuations can still mimic electron signals (fake electrons) • Two pattern recognition algorithms are developed for electron ID HBD module before subtraction: HBD module after subtraction: Posters: E. Atomssa and Y. Watanabe Run 10, Au+Au M. Makek, QM2011

  12. The HBD analysis in Au+Au:matching of tracks to the HBD • Use the track projection point on the HBD to pre-determine the cluster size • The cluster is accepted if its charge is above a predetermined threhold Plots by Y. Watanabe • This algorithm slightly truncates the charge but ensures high rejection and good efficiency M. Makek, QM2011

  13. The HBD analysis in Au+Au:matching of tracks to the HBD • Very high rejection achieved while keeping a high efficiency even in the most central events • Monitoring the efficiency and the rejection: • Efficiency studied using MC electrons from f-> e+e- embedded in Au+Au data • Rejection of mis-identified hadrons and random matching determined from the data Centrality: M. Makek, QM2011

  14. The HBD analysis in Au+Au:rejection of p0Dalitz electrons and upstream conversions • The rejection of the upstream conversions and p0 Dalitz pairs is achieved with single/double charge cut • This requires good gain calibration throughout the entire run • Single electrons hits studied using MC electrons from f->e+e- emebedded in Au+Au data • Double electron hits studied using MC p0->gg emebedded in Au+Au data Single vs. double charge Single efficiency vs. double rejection Singles efficiency Doubles rejection Run 10, Au+Au M. Makek, QM2011

  15. The HBD analysis in Au+Au:monitoring the analysis chain • Full event HIJING simulation of 0-10% central Au+Au events • Study the full analysis chain: electron detection efficiency, rejection of upstream and downstream conversions, electrons from p0 Dalitz decays, hadrons and the subtraction of the residual combinatorial background • Example - applying the matching to the HBD: • Pairs: S  S (0.83)2 B  B /(3.5)2 Only by matching to the HBD: S/B  8.4 S/B M. Makek, QM2011

  16. Conclusion and Outlook • The HBD was successfully operated in the PHENIX set-up in Run-9 (p+p) and Run-10 (Au+Au) • Detector performed up to design specifications • excellent electron detection efficiency • good separation between electrons and hadrons • good separation of single and double electron hits • Two different algorithms for HBD electron ID in central Au+Au collisions were developed showing consistent results: • successful handling of scintillation background • High rejection of fakes keeping high electron efficiency First mass spectra from Run-10 Au+Au are expected soon. M. Makek, QM2011

  17. BACKUP slides M. Makek, QM2011

  18. Measured data sets Run-9: • p+p collisions at 500 GeV: • Recorded 0.01 nb-1 • p+p collisions at 200 GeV • Recorded 0.02 nb-1 Run-10: • Au+Au collisions at 200 GeV: • Recorded 1.3 (1.1) nb-1 or 8.2B (7.0B) events in +/-30 (+/-20) cm vertex (5x data than in Run-4) • Au+Au collisions at 62.4 GeV: • Recorded 0.1 nb-1 or 700M events in +/-30 cm vertex • Au+Au collisions at 39 GeV: • Recorded 0.04 nb-1 or 250M events PHENIX Integrated luminosity in Run-10 200 GeV M. Makek, QM2011

  19. PHENIX detector Inner and outer magnet coils producing field-free region for r < 55 cm M. Makek, QM2011

  20. Quantum efficiency Quantum efficiency of the photocathode was monitored with the “Scintillation Cube” Quantum efficiency kept constant during the two years of operation! M. Makek, QM2011

More Related