GenSet Test Update, Literature Review Lab Gas Generators. Nick Johnson 2-19-08 NBEL Wayne State University. Outline. Engine Update Literature Review Published Reports of Similar Tests Specific Gravity of ULSD for Genset Test Nitrogen Generators. Engine Update.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'GenSet Test Update, Literature Review Lab Gas Generators' - tamar


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
genset test update literature review lab gas generators

GenSet Test Update, Literature Review Lab Gas Generators

Nick Johnson

2-19-08

NBEL

Wayne State University

outline
Outline
  • Engine Update
  • Literature Review
    • Published Reports of Similar Tests
  • Specific Gravity of ULSD for Genset Test
  • Nitrogen Generators
engine update
Engine Update
  • Exhaust Filter Plugged up
    • Waiting on replacement filter
    • Plugged up holes when not using smoke meter
  • Reinstall smoke meter piping
  • Move Thermocouple to after Smoke Meter to reduce Swirl
  • Possible installation of Thermocouple location before muffler for more accurate exhaust temperature reading
literature review for soot levels in lubricating oil
Literature Review for Soot Levels in Lubricating Oil
  • “Effect of diesel soot on lubricant oil viscosity” George, S et. al… WVU ME Dept 2006
    • Soot levels predetermined and set into 3 various categories 0%, 2%, 4%
    • Test samples conducted on Wells-Brookfield viscometer at 40C and 90C using an ounce of oil
    • Used various oils and soot was actually scraped off inner exhaust manifold and added to oil
    • Other Variants in oil kept constant throughout all the tests
literature review for soot levels in lubricating oil1
Literature Review for Soot Levels in Lubricating Oil
  • As soot viscosity was shown to increase thus accelerating the wear characteristics
  • Dispersants are added to counteract and keep soot suspended

“Effect of diesel soot on lubricant oil viscosity” George, S et. al… WVU ME Dept 2006

literature review for soot levels in lubricating oil2
Literature Review for Soot Levels in Lubricating Oil

“Effect of diesel soot on lubricant oil viscosity” George, S et. al… WVU ME Dept 2006

literature review for soot levels in lubricating oil3
Literature Review for Soot Levels in Lubricating Oil
  • As soot viscosity was shown to increase thus accelerating the wear characteristics
  • Dispersants are added to counteract and keep soot suspended

“Effect of diesel soot on lubricant oil viscosity” George, S et. al… WVU ME Dept 2006

nitrogen generators
Nitrogen Generators
  • Contacted two companies
  • PerkinElmer has Nitrogen generator specific for OES-ICP
    • Contacted left message for our product specialist
  • Maxigas Nitrogen Generators
    • Contacted and they are putting together an economic analysis comparison to our N2 tanks we are currently using
  • We need UHP Nitrogen i.e. 99.999% so can’t buy a typical generator ~ increased cost
future work
Future Work
  • Get Engine Running again
  • Develop Daily Procedure for Start Up / Shut Down and with Kapila
  • Measure Specific Gravity of S-8
  • Continue to find Literature on Soot Analysis
  • Purchase of Lab Gas Generators and Installation