An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 质量问题8D分析处理报告 Customer Comment Report No:2009919001 客户 Customer :whirpool D-1:问题陈述Problem Statement:关韶峰 日期 Date:2009-9-12 送给惠而浦(EC928AWP)做测试的样品不合格 D-2:小组成员Core team

  2. D-3:补救措施 Containment Action 改善后重新送样 负责人Person in charge:关韶峰 日期Due Date:待定 D-4:过程不良描述Process Findings 我司送给惠而浦(EC928AWP)做测试的样品,客户跌落(高度46MM)4台后发现有一台U板压型处裂开严重。 成员 Member:关韶峰 日期 Due Date:2009-9-12

  3. D-5:根本原因分析Root Cause Analysis 1、材料原因:库存材料物理性能测试 检测技术要求:拉伸速度V=5mm/min,并参考GB/T 228-2002 经检验符合美的要求 成员 Member:潘永华、郭立新 日期 Due Date:2009-9-18

  4. 2、模具原因: 波导管压型R角过小,导致板材R角位材料暗裂 成员 Member:彭任平、郭立新 日期 Due Date:2009-9-13 D-6:纠正措施(短期)Corrective Action, short term 对模具进行维修,将R角修大 成员 Member:周国彬 日期 Due Date:2009-9-18

  5. D-7:预防措施(长期)Preventive Action, long term 1、模具日常检查; 2、检验项目更新: 从检验入手,增加全检内容,制作检验工具,不光可以检验压型暗裂,同时可以检验波导管、磁控管支架的焊接效果。 成员 Member:靳继龙 日期 Due Date:2009-9-18 D-8:结果确认Verification of effectiveness 能有效纠正预防此问题 成员 Member: 祝高明 日期 Due Date:2009-9-19