1 / 7

Status of the Organics Detection System Upgrade ODS Network and Website

Status of the Organics Detection System Upgrade ODS Network and Website CMS 5000 Process GC/ Purge and Trap. The ODS website displays the current status of each of the sites Green dots indicate that data is successfully being uploaded to the secure website

sue
Download Presentation

Status of the Organics Detection System Upgrade ODS Network and Website

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Status of the Organics Detection System Upgrade • ODS Network and Website • CMS 5000 Process GC/ Purge and Trap

  2. The ODS website displays the current status of each of the sites Green dots indicate that data is successfully being uploaded to the secure website By selecting the sites you can view recent VOC data for that site

  3. Daily organics detection system data is available remotely using a password protected website Volatile organic carbon data from ODS sites is displayed automatically and updated as new data is available

  4. ODS Network Progress to Date • All ODS Sites have been networked • ORSANCO staff can access all of the ODS sites remotely to troubleshoot, review chromatography data and provide training • The Sites with CMS have been setup to log data to the ODS Website Moving Forward • The reports generated by the Thermo GC/MS will be set up to export to the ODS website • Compound Names will be standardized • Reports on the website will include unknown compound detections

  5. The CMS 5000 Process GC/ Purge and Trap • CMS 5000s are currently in use at Midland, Ashland and Cincinnati Water Works • An additional CMS is scheduled to be installed at Wheeling Water • The CMS 5000 monitors VOCs at user defined intervals allowing for around the clock operation • Unlike previous process VOC instrumentation, the CMS 5000 uses large diameter fittings and is perfectly suited for the demands of real time monitoring of Ohio River water

  6. Total Number of Ohio River Water samples analyzed for 2013: 4589 For Upgraded ODS sites Total Number of Ohio River Water samples analyzed by ODS sites that have been upgraded: 1821 Number of volatile organic compound detections over 2ppb: 32 For the upgraded ODS sites detections over 2 parts per billion occurred in less than 2% of Ohio River water samples. Of the volatile organics detected the trihalomethanes were by far the most common.

  7. ODS Detections 2012