1 / 10

Pathology with Paper and Pencil

Pathology with Paper and Pencil. [Ref: P. Mandal, R. Dey, S. Chakraborty, Lab Chip, 2012, 12, 4026-4028]. Normal filter paper. Filter paper soaked in photoresist ; prebaked. Mask for UV exposure. Paper channel. Fabrication of Complex Structures on Paper.

sonyac
Download Presentation

Pathology with Paper and Pencil

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Pathology with Paper and Pencil [Ref: P. Mandal, R. Dey, S. Chakraborty, Lab Chip, 2012, 12, 4026-4028] Normal filter paper Filter paper soaked in photoresist; prebaked Mask for UV exposure Paper channel

  2. Fabrication of Complex Structures on Paper Zigzag design to investigate mixing H-channel designed to investigate blood cell separation 13 11 9 7 5 3 1 12 10 8 6 4 2

  3. Colorimetric Detection of Blood Glucose and Multiplexing Glucose detection process Calibration with standard glucose samples Brown color developed Paper microchannel Glucose Reagent Blood Sample Separation + Reaction Reagents • Whatman grade 1 • Length = 20 mm • W = 3 mm, Φ = 7 mm Plasma separated from RBC Blood sample to source pad Antibody (ABO) Calibration curve with Standard glucose Image Acquisition Image Processing Result Display Protein assay Anti A-B Multiplexing: • Simultaneous detection of multiple analytes like glucose and protein etc. • Blood group Identification Anti O Glucose assay

  4. Paper-based Kits for Antimicrobial Susceptibility Assays Prototype: Indian patent file no: 201631023867 Working protocol: Microfluidics and Microscale Transport Processes Laboratory

  5. Towards a Commercializable Device Functional block diagram of the med Colorimeter. Paper Based Micro-fluidic Sensor with Blood Sample Micro-controller/ Digital Signal Processor LED based calibrated light source Calibrated photo detector Trans-impedance amplifier + filters Analog to Digital Converter Smart Phone Bluetooth Low Energy Transceiver A/Prof. Sudip Nag Prof. Suman Chakraborty

  6. Prototype Design Paper Based Blood Sample Sensor Battery Calibrated LED with Driver and Optical Detector Opaque Enclosure Bluetooth Low Energy Transceiver

  7. Specification of the Prototype

  8. Acknowledgement Faculty Member Dr. Sudip Nag Department of E&ECE IIT Kharagpur, INDIA Researchers and Students Dr. Shantimoy Kar (former Ph.D student) SujayBiswas (current Ph.D student)

  9. Acknowledgement Researchers and Students Dr. Shantimoy Kar SujayBiswas

  10. Collaborative partners and funding Agencies

More Related