1 / 30

Automation Totalflow Measurement & Control Systems Product Overview

Automation Totalflow Measurement & Control Systems Product Overview. Background of Totalflow. Based in Bartlesville, OK USA History of Totalflow Formerly a research division of Phillips Petroleum Co. Incorporated in 1968 Acquired by H&B in 1988 Acquired by EB in 1995

sonel
Download Presentation

Automation Totalflow Measurement & Control Systems Product Overview

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Automation Totalflow Measurement & Control Systems Product Overview

  2. Background of Totalflow • Based in Bartlesville, OK USA • History of Totalflow • Formerly a research division of Phillips Petroleum Co. • Incorporated in 1968 • Acquired by H&B in 1988 • Acquired by EB in 1995 • Acquired by ABB in 1999 • ISO 9000 certified • Capabilities • Design, Manufacture, Test, Systems Integration, Document, Customer Service, Training • Two product lines • Analytical - Chromatograph, IR, FTIR, Continuous Analyzers • Totaflow - Remote Measurement and Control Systems Sold w/ABB purchase

  3. ABB Bartlesville-Analytical • Analytical • Fourier Transform Infrared Analyzer (FTIR) • Environmental Monitoring Technology • Infrared Spectrometer (NDIR) • Ultraviolet Spectrometer (UV) • Oxygen Analyzer (O2) • Thermal Conductivity Analyzer (TC) • Analytical Systems Packaging • Training

  4. ABB Bartlesville-Totalflow • Totalflow • Remote battery powered flow computers • Remote battery powered RTUs • PC/Windows and Networked Host Systems • Ruggedized Hand-Held / Laptop Computer Software • Application Specific Software • System Integration / Project Management • Customer Services • Training

  5. Remote System Distinctions • Low Power Consumption • Harsh Environment • High Quality (Dependable) • Low Cost / High Volume • Low Operating Costs • Mimimize Trips To Sites & Provide Near Realtime Data • Data Reduction / Storage • Two Way Communications • Alarm on Exception • Remote Intelligence to Measure, Monitor, Alarm and Control • Hazardous Area Classifications • Secure Against Intrusion

  6. Fundamental System Components • Remote Unit - Ruggedized, low power units performing measurement, monitor, alarm, control and communications Remote Unit

  7. Fundamental System Components • Remote Unit - Ruggedized, low power units performing measurement, monitor, alarm, control and communications • Portable Computer - For ease in initial setup and calibration of remote units(PCCU) Portable Computers Remote Unit

  8. Fundamental System Components • Remote Unit - Ruggedized, low power units performing measurement, monitor, alarm, control and communications • Portable Computer - For ease in initial setup and calibration of remote units(PCCU) • Host System - Computer or networked computers performing engineering, SCADA, data collection and data management functions. Host System or Other RTU Remote Comm Portable Computers Remote Unit

  9. Originally - Gas Orifice Chart System Replacement Chart Measurement System - Chart Measurement (FCU) - Chart Calibration (FCU,PCCU) - Chart Collection (FCU,PCCU,CCU) - Chart Integration (FCU) - Volume Calcs (FCU) - Chart / Volume Recalcs (CCU) - Chart Archival (CCU) - Data / Calcs Audits (FCU,CCU) - Chart Operational Info (FCU,PCCU,CCU) Totalflow Measurememt System - Flow Computer - PCCU Handheld - CCU Host Software - (Communications Systems) Gas Accounting

  10. Types of Remote Units • Ruggedized Measurement Devices • Flow Computers - Emphasis on volume measurement • Natural Gas Chromatograph - Emphasis on energy measurement • Tank Level - Emphasis on level and volume measurement (single or dual levels with temperature) • Highly accurate transducers and algorithms • Measurement database that maintains audit history • Small amount of additional I/O functionality

  11. Types of Remote Units • Ruggedized Measurement Devices • Flow Computers - Emphasis on volume measurement • Natural Gas Chromatograph - Emphasis on energy measurement • Tank Level - Emphasis on level and volume measurement (single or dual levels with temperature) • Highly accurate transducers and algorithms • Measurement database that maintains audit history • Small amount of additional I/O functionality • Ruggedized RTU / Programmable Controller • Emphasis on flexible measurement and control applications • Good measurement • Flexible, realtime control language • General purpose I/O and data

  12. Types of Remote Units • Ruggedized Measurement Devices • Flow Computers - Emphasis on volume measurement • Natural Gas Chromatograph - Emphasis on energy measurement • Tank Level - Emphasis on level and volume measurement (single or dual levels with temperature) • Highly accurate transducers and algorithms • Measurement database that maintains audit history • Small amount of additional I/O functionality • Ruggedized RTU / Programmable Controller • Emphasis on custom measurement and control applications • Good measurement • Flexible, realtime control language • General purpose I/O and data • Hybrid Measurement and RTU/PLC Devices • without jeopardizing fluid measurement accuracy / operation

  13. 6400 Flow Computer 6413 Orifice • Standard Features(6410 / 6411 & 6413 / 6414) • Low-cost single run design • Aluminum powder coated enclosure • Class 1, Div 1 & 2, FM & NRTL/C • Full AGA calculation options • Smart SP & DP transducers • 100 ohm RTD Temp element • API 21.1 Custody Transfer • Orifice and Pulse Units • 3 Com Ports (1 Local, 2 Remote) • Some additional onboard I/O • 2 AI, 2 DI/PI, 2 DO • Onboard Applications • Flow weighted composite sampler • Pump off control • Alarm Monitoring / Exception Reporting 6411 Turbine

  14. Analog Measurement Unit (AMU)Foundation for Accuracy • “Smart” Static and Differential Pressure Transducers • Transducers and Analog Electronics Characterized • Factory Calibrated • 0.2% Lin,Hyst,Repeat(0.05% available) • 0.25% Total Temp Effect OverRange (-29 to 60 C / -20 to 140 F) • 18 Bit A/D Conversion(0.0004 % Resolution) • EMI/RFI Shielded • 26 - 1000 MHz @ 30 v/m • Digital link to main board

  15. 6700 Flow Computer • Standard Features(6713 / 6714) • Larger Enclosure • power systems • Class 1, Div 1 & 2, FM & NRTL/C • Enhanced Communications • (3) comm ports • Full AGA calculation options • Orifice and Pulse Units • Same Transducers as 6400 • API 21.1 Custody Transfer • Some additional onboard I/O • 2 AI, 2 PI, 6 DI, 6 DO • Expandability (AO or PI-RTU board) • Some On Board Applications • All 6400 applications • Valve Control • Nominations • Multi-tube Meter Station

  16. 6713 Flow Computer Optional Pressure Transmitter Valve Control (Digital or Analog) • Differential Pressure Control • Static Pressure Control • Flowrate Control • DP Overrides (Hi and Lo) • Static Pressure Overrides • On/Off Timer and or Pressure Operation • Nominations

  17. Nomination Set-up

  18. E/P 6700 Multi-Run Application(with Valve-Control & Run-Switching) Flow Rate 6410 Flow rate 6410 Station Flowrate Control Valve Flow Rate (1 + 2) 6713 (base board) Primary Tube FlowRate = FR1 + Fr2 + FRprimary

  19. Applied Automation, Inc. • a unit of Elsag Bailey Process Automation N. V. PO Box 9999 • Bartlesville, Oklahoma, USA, 74005 • Phone 918-662-7000 • Fax 918-662-7052 Applied Automation, Inc. Totalflow Division Programmable RTUs

  20. Totalflow Model 6790 Stand-Alone RTU - PLC • 6790 Low Cost / Rugged (NEMA 4X) • 6790A Lower Cost Wall Mount • General Purpose I/O • 8 DIs, 8 DOs, 7 AIs, 2 PIs, 1 to 4 AOs • Battery Powered • Solar, AC or DC Charging • Control Language • Graphically Enhanced Ladder LOgic (GELLO) • Logic, Conditionals, Timers, Control, and Math (Integer or Float) Primitives • PID, Some Volume Equations • Pre-Engineered Solutions • 4 Comm Ports • 1 Local, 1 Remote (232 or 485), 1 Aux232, 1 Aux485

  21. GELLO Program Page

  22. Totalflow Plug-In RTU • Plugs Into Existing Flow Computers • Model 6610, 6613, 6713 • Functional Equivalent to6790 Stand Alone RTUExcept……. • Powered from Flow Computer • Shares Flow Computer Display • Comm link with flow computer • 3 Comm Ports • 1 Local, 1 Remote, 1 Flow Computer I/O Counts 6713 Base Board Pf, DP, Tf, Battery, 2 AI, 6 DI, 6 DO, 2 PI Plug-In RTU 7 AI, 8 DI, 8 DO, 2 PI, 1 to 4 AO Total Pf, DP, Tf, Battery, 9 AI, 14 DI, 14 DO, 4 PI, 1 to 4 AO

  23. Totalflow Model 8000BTU / Calorific Value Transmitter • Ruggedized Natural Gas Chromatograph • Cenelec, Zone 1, Eex d IIB • NRTL Class 1, Div 1, Groups C&D • Operating Range -18 to 50 Deg C • Weatherproof (No Shelter) • NEMA 4X, IP-65 • Mount Directly to Pipeline(wall optional) • 3-Stream Plus Cal Stream • 3-Minute Cycle (N2 - C6+) Intrinsic Safe Barrier Explosion Proof

  24. Totalflow Model 8000BTU / Calorific Value Transmitter • Calculated Values • BTU/CV, Specific Gravity,Wobbe, GPM(GPA 2172 / ISO 6976) • Repeatability of +/- 1 BTU per 1000 • Minimum Utilities • No Instrument Air • Solar Power Option • Low carrier gas consumption • 1 to 2 bottles per year • Depends on cycle time 3 Stream SampleCondition Module 3 Stream SampleSystem Module

  25. Totalflow Model 8000BTU / CV Transmitter • Modular Design • Controller Assembly Module • Model 40 GC Module • Pressure Regulator Module • Sample System Module • Solenoid Block Manifold • I.S. Termination Board • Power Termination Board • Low cost of ownership • Lower Installation Costs • Minimum Utilities • Often No Building • Lower Maintenance Costs • Minimum Training Required

  26. Natural Gas Energy Measurement • Combination of • Gas Flow Computers and • BTU/CV Transmitter • Realtime Integration ofQuantities • Volume and • Energy • Complete Measurement Databases • Remote Communications

  27. 6300 Pump Off Controller • Pump Off Controller • Increases Production • Reduces pump runtime / maintenance • Extends life of pump • Based on DJAX algorithm embedded within(Pump off predicted with speed increase of pump due to loss of liquid load) • 6313 POC Unit • 6400 Series FCU • 6700 Series FCU • 6790 Series RTU

  28. Level Master • Level Master-Tank Level Technology • Single or Dual Level Floats • Temperature • Wide Range ofFluid Services • Low Power • RS485 Interface • 2 to 45 feet tanks • High accuracy 0.04”(1 mm) technology

  29. TOTALFLOW AA TOTALFLOW AA Communications Experience • Multiple Address Radio • Spread Spectrum Radio • Cellular Phone Systems(including CDPD) • Microwave • Phone Modems • Satellite Systems • Hardwire • RS-232 • RS-485 • RS-422

  30. Protocols • Totalflow Low Power • Totalflow Low Power Packet Protocol • Totalflow Modbus • Totalflow Modbus (low power) • Enron Modbus • Transco Modbus • Square-D • Terbus • Level Master • Will Quote Custom